1.

What Article in the NEC book covers Box Fill?

a)

210.16

b)

314.16

c)

842.10

d)

210.52

2.

How many #12 wires can we install in a Metal 4" x 2-1/8" Square Box.

a)

15

b)

10

c)

20

d)

13

3.

How many Cubic Inches are there in a Metal 4" x 1-1/2" Round Box?

a)

15.5

b)

21.2

c)

12.5

d)

14

4.

How many #10 wires are allowed in a 3" x 2" x 3-1/2" Device Box

a)

5

b)

6

c)

7

d)

8

5.

When calculating the cubic inches being taken up in a box with mixed gauge wires, #12 Gauge wire is counted as __________ Cubic inches

a)

2

b)

2.25

c)

2.50

d)

2.75

6.

Which of the following lists 1 of the The Box Capacity Deductions taken into account when Calculating Box Fill.

a)

Wires Nuts

b)

Cable Connectors

c)

Pig Tales

d)

Stud

7.

The GFCI Receptacle shown on the Picture counts as ________ Wire(s)

a)

2 # 12s

b)

2 - #20s

c)

2 - #14

d)

1- #12

8.

In the Picture shown there are 2 switches wires with #14 Gauge wire and 1 Receptacle wired with #12 Gauge Wire. The combination Device (Switch/Receptacle) on the right count as _____

a)

3 #12s

b)

4 # 12s

c)

2 #12s

d)

2# 114s

9.

If we have a 3" x 2" x 2-1/2" Device Box with 3 - #12s Non-Metallic cables, All the equipment Grounding wires combined count as _____

a)

3 -#12s

b)

4 -#12s

c)

2 - #12s

d)

1 -#12

10.

In which of the following boxes can you find a hickey

a)

4" x 2-1/8 Round Box Bar Box

b)

3" x 2" x 2 -3/4" Device Box

c)

4" x 1-1/2" Square Box

d)

4" x 2-1/8" Square Box

11.

How many Cubic Inches will 6 #14 wires take up in a box?

a)

6

b)

20

c)

15

d)

28

12.

After 4 Equipment Grounding Conductors in a box, we have to count each additional Grounding wire as _______ of a wire.

a)

1/3

b)

1/4

c)

1/2

d)

1/8

13.

How many Cubic Inches does a 4-11/16" x 1-1/4" Square Box have

a)

12.4

b)

172

c)

418

d)

25.5

14.

How many wires are deducted for a Yoke/Strap?

a)

1

b)

2

c)

3

d)

4

15.

4 CLAMPS in box with three 14-2 Romex cables inside, count as

a)

1 #14

b)

4 #14

c)

2 #14

d)

Clamps do not count

16.

How do you determine how many #14 wires you are allowed in a Plastic Nail-on Box

a)

Look it up in the NEC Book

b)

There is no way to determine number of wires in a box without calculating it

c)

The information is printed in the inside of the box

d)

Look up wires in the NEC Book

17.

How do you find out how many #12 gauge wires we are allow in a metal box

a)

Look it up in the NEC Book

b)

The information is printed in the box

c)

11 # 12

d)

There is no limit to the #12 wires we can put in a metal box

18.

Metal 4" Round boxes are also known as

a)

4" Square Boxes

b)

4" Octagonal Boxes

c)

4" Device Boxes

d)

3 x 2 x 2-1/4 Device Box