Worksheets8 Mendiagnosis kerusakan sistem Air Conditioning (AC)
Total questions: 10
Worksheet time: 10mins
JIKA PERBEDAAN TEMPERATUR ANTARA INLET DAN OUTLET TIDAK DAPAT DIRASAKAN, MAKA DAPAT MENIMBULKAN.....
SUARA BERISIK PADA PIPA
OUTLET VALVE TERLALU DINGIN
KOPLING MAGNET BERISIK
OUTLET VALVE TIDAK DINGIN
KOMPRESOR BERISIK
URUTAN SIKLUS PENDINGIN YANG BENAR ADALAH.....
COMPRESOR-EVAPORATOR-RECAIVER-CONDENSER-EXPANSION VALVE
COMPRESOR-CONDENSOR-RECAIVER-EVAPORATOR-EXPANSION VALVE
COMPRESOR-CONDENSER-RECAIVER-EXPANSION VALVE-EVAPORATOR
COMPRESOR-RECAIVER-CONDENSER-EXPANSION VALVE-EVAPORATOR
COMPRESOR-EXPANSION VALVE-DRIER-EVAPORATOR-CONDENSER
DI BAWAH INI YANG TERMASUK ZAT PENDINGIN (REFRIGERANT) YANG SUDAH DILARANG PEMAKAIAN KARENA MUDAH TERBAKAR ADALAH......
R 12
R 134e
ZAT ASAM
HFC 22
LIQIUD PETROLEUM GAS
BERIKUT GEJALA YANG TIMBUL AKIBAT KEKURANGAN REFRIGERANT, KECUALI.....
UDARA YABG KELUAR DARI SISTEM PENDINGIN TIDAK TERLALU DINGIN
PADA KACA PENGINTAI TERLIHAT BANYAK GELEMBUNG
PADA KACA PENGINTAI TIDAK TERLIHAT GELEMBUNG
PENGUKURAN TEKANAN RENDAH 0,8 kg/CM2 ( 11 psi, 78 Kpa )
PENGUKURAN TEKANAN TINGGI 8,0 kg/CM2 ( 114 psi, 882 Kpa )
KOMPONEN PADA SISTEM AC YANG BERFUNGSI UNTUK MENGUBAH SEBAGAI ATAU KESELURUHAN SEBUAH PELARUT DARI SEBUAH LARUTAN DARI BENTUK CAIR MENJADI UAP ADALAH.....
EVAPORATOR
EXPANSION VALVE
RECEIVER/DRIER
KOMPRESOR
KONDENSOR
JIKA EXPANSION VALVE TIDAK BEKERJA DENGAN BAIK, MAK KETIKA DIPERIKSA DENGAN MANIFOLD GAUGE PADA TEKANANRENDAH AKAN TERUKUR.....kPa
2,5
20
36
245
1.863
PADA SISTEM PENYEJUK UDARA KOMPRESOR YANG BERFUNGSI UNTUK MEMUTUS DAN MENGHUBUNGKAN KOMPRESOR DENGAN PENGGERAKNYA (PUTARAN MESIN) ADALAH.....
EVAPORATOR
RECEIVER/DRIER
KOMPRESOR
MAGNETIC CLUCTH
BLOWER
KACA DUGA DAPAT DIGUNAKAN UNTUK MENDETEKSI GANGGUAN PADA SISTEM PENYEJUK UDARA. BERIKUT INDIKASI-INDIKASI YANG MUNCUL PADA KACA DUGA, KECUALI.....
KACA DUGA BERSIH MENUNJUKKAN MUATAN YANG PAS/TEPAT
GELEMBUNG MUNCUL TIBA-TIBA/SEKALI-SEKALI PADA SAAT DIHIDUPKAN MERUPAKAN GEJALA NORMAL
JUMLAH GELEMBUNG BANYAK SEPERTI BUSA PADA KACA MENUNJUKKAN JUMLAH REFRIGERAN SANGAT SEDIKIT
BILA PADA KACA TERDAPAT GARIS-GARIS OLI BERARTI REFEGERAN DI DALAM SISTEM SUDAH KOSONG
KACA DUGA BERSIH REFRIGERAN DI DALAM SISTEM KOSONG SEHINGGA RUANG PENUMPANG AKAN TERASA PANAS
BERIKUT PENYEBAB TIDAK ADA KOMPRESI PADA KOMPRESOR ADALAH.....
KOMPRESOR RUSAK
KATUP EKSPANSI TERSUMBAT
PENYETELAN ALIRAN TIDAK BAIK
EVAPORATOR TERSUMBAT
KOMPRESOR TERSUMBAT
SETELAH SELESAI PROSES PENGOSONGAN, TUTUP KEDUA KATUP DAN TUNGGU KURANG LEBIH 15 MENIT. HAL INI DIPERLUKAN UNTUK MEMASTIKAN.....
SISTEM TETAP DALAM KEADAAN VAKUM
TIDAK ADA KEBOCORAN DALAM SISTEM
SISTEM BEKERJA DENGAN BAIK
JUMLAH REFIGERAN
SISTEM TETAP BERSIH