wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

AP L3 Sanitation Phase 2 pt1

Total questions: 24

Worksheet time: 12mins

Name
Class
Date
1.

Which of the following Britsh Standards covers Workmanship on building sites. With Part 13 covering the installation of drainage and sanitation systems?

a)

BS EN 12056-2:2000

b)

BS EN12056-5:2000

c)

The Water Supply (Water Fittings) Regulations 1999

d)

BS 8000-13

2.

What is the maximum length of a WC branch?

a)

2m

b)

4m

c)

6m

d)

8m

3.

What is the maximum length of pipe run permitted with appliances connected with 50mm waste pipe?

a)

2

b)

4

c)

6

d)

8

4.

What is shown in the image?

a)

Pigmy Trap

b)

Straight Trap

c)

Waterless Trap

d)

French Flange Trap

5.

Bends at the base of discharge stacks should be large-radius with a minimum radius of _____?

a)

150mm

b)

200mm

c)

265mm

d)

380mm

6.

Traps are generally manufactured to what Standards?

a)

BS EN 274:2002

b)

BS 5627

c)

BS EN 12380

d)

BS EN 1566

7.

What is shown in the image?

a)

P Trap

b)

S Trap

c)

Bath Trap

d)

Running Trap

8.

What is the Trap Seal Depth when fitted to a primary ventilated system (BS EN 12056-02) of a Wash Basin pipe size of 32mm Diameter

a)

75mm

b)

50mm

c)

25mm

d)

100mm

9.

What is the Trap Seal Depth when fitted to a primary ventilated system (BS EN 12056-02) of a Bath pipe size 40mm Diameter

a)

75mm

b)

50mm

c)

25mm

d)

100mm

10.

How does an Anti-vac trap work?

a)

An Anti-vac trap uses a small air admittance valve.

b)

An Anti-vac trap uses a small silicone flap

c)

An Anti-vac trap uses a small stainless steel ball valve

d)

An Anti-vac trap uses a small P-trap assembly

11.

What is shown in the image?

a)

Stop Valve

b)

Water Valve

c)

AAV

d)

Max Trap

12.

In the 1950s, what was a common material used to manufacture Soil Pipes?

a)

Aluminium

b)

Cast Iron

c)

Stainless Steel

d)

Copper

13.

There are two British Standards that must be consulted when installing sanitation systems. What are they?

a)

BS EN 12056-05:2000 + BS EN 8700

b)

BS EN 12056-05 + BS 8000 Part 13:1989

c)

BS EN 1455 + BS 8000

d)

BS EN 274 + BS EN 1455

14.

How is trap seal loss measured?

a)

Using a take measure

b)

Using your finger

c)

Using a plunger

d)

Using a dipstick

15.

What is shown in the image?

a)

Shower Trap

b)

Washing Machine Trap

c)

Bath Trap

d)

Anti-syphon Bottle Trap

16.

After a performance test, the depth of water that should be retained in the trap to a washbasin is?

a)

25mm

b)

35mm

c)

45mm

d)

50mm

17.

The fitting that should be used at the termination of a soil and vent pipe is a?

a)

Guarded bend

b)

Straight Coupling

c)

Standoff Pipe fastening

d)

Wire or Plastic mesh cage

18.

The gradient for a bath waste should be between?

a)

18 - 90

b)

18 - 22

c)

18

d)

18 - 75

19.

The lowest connection to the soil stack on ‘low-rise’ buildings (two storeys) is?

a)

750 mm

b)

450 mm

c)

650 mm

d)

350 mm

20.

No connection are allowed to be made opposite a WC connection within how many mm?

a)

150

b)

200

c)

250

d)

300

21.

A soil pipe must rise at least 900 mm above a window when it is within?

a)

1 m

b)

1.5 m

c)

2.5 m

d)

3 m

22.

An AAV valve must be fitted at what height above the highest spillover level?

a)

500 mm

b)

250 mm

c)

450 mm

d)

1000 mm

23.

The building regulation that covers ventilation is?

a)

F

b)

H

c)

G

d)

A

24.

The building regulation that covers drainage is?

a)

F

b)

H

c)

G

d)

A