wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Central Heating 6035-02 | Part 2

Total questions: 40

Worksheet time: 21mins

Name
Class
Date
1.

When the zone valves close, the boiler switches off and when the heat is dissipated from the heat exchanger, the circulator will switch off. This is known as?

a)

Boiler interlock

b)

Negative pressure

c)

Positive pressure

d)

Background heating

2.

What is the component shown?

a)

Boiler thermostat

b)

Cylinder thermostat

c)

Room thermostat

d)

Programmer

3.

The Water Regulations states that after the system has been charged, the filling loop needs to be?

a)

Remain attached and on to keep the charge

b)

Removed from the property to prohibit homeowner operation

c)

Disconnected to prevent additional charges in the system

d)

Remain attached in order for easy refill of system

4.

STATEMENT: Boilers installed on any system must always be positioned lower than the systems clyinder.

a)

True

b)

False

5.

Which component is included on a fully pumped Y-plan system that differentiates it from the S-plan system?

a)

2 two port valves for hot water and heating

b)

A three port valve

c)

A bypass valve

d)

The cylinder thermostat

6.

Which of the following boilers use one heat exchanger to heat up the primary water, allowing the latent heat to be expelled to atmosphere?

a)

Condensing boilers

b)

Traditional boilers

c)

Convectional boilers

7.

STATEMENT: Unlike the two-port motorised valves, the three-port mid-position valve always allows a flow of water through the valve.

a)

True

b)

False

8.

Which of the following is not a benefit to having underfloor heating installed?

a)

Improved comfort

b)

Flexibility

c)

Very low maintenance

d)

Pricey installation

9.

What is the component shown?

a)

Manifold

b)

4-way coupling

c)

Continuous tee fitting

d)

Male iron to copper connection

10.

To correctly balance the system, what should be worked out? (Choose 2)

a)

How long the system takes to heat up

b)

How many full turns it takes to heat up

c)

How many radiators are in the system (plus 1)

d)

What type of property the customer has

11.

What would be a disadvantage to having a C plan two pipe semi gravity system installed?

a)

No heat emitter is at lower temperatures

b)

A faster heat-up time

c)

Boilers in this system tend to be of a lower efficiency

d)

L1b Building Regulation compliant

12.

What can be avoided by the correct positioning of the circulator? (Choose 2)

a)

Positive pressure

b)

Circulator pumping over

c)

Circulator drawing air in

d)

Circulator pumping backwards

13.

What is the component shown?

a)

Filling loop

b)

Flexible tap connector

c)

Flexible service valve

d)

Automatic bypass valve

14.

Why is the position of the circulator pump important to produce positive pressure? (Choose 2)

a)

To avoid air entering

b)

To prevent positive pressure

c)

To prevent a negative pressure

d)

To prevent corrosion

15.

The base of the F&E should be where compared to the CWSC?

a)

The same base level as CWSC

b)

Above the base level as CWSC

c)

Below the base level as CWSC

16.

What building regulation covers the conservation of fuel and power?

a)

Part L

b)

Part K

c)

Part G

d)

Part P

17.

The component shown is on a two port motorised valve. What is the name of the component?

a)

Sensor module

b)

Boiler thermostat

c)

Automatic air vent

d)

Synchron motor

18.

Which of the following is the wheel head valve?

a)
b)

c)

19.

Radiators without fins welded to the back of them rely heavily on what transfer of heat?

a)

Convectional heat

b)

Conductive heat

c)

Radiated heat

20.

The purpose of a frost thermostat and pipe thermostat is?

a)

Tell' the boiler that the system is up to the correct temperature

b)

Tell' the boiler to flow hot water through the pipes when they are frozen

c)

Briefly activate the boiler to warm up pipe in vulnerable areas

d)

Send a signal to the boiler that the temperature is close to overheating

21.

STATEMENT: The position of the circulator does not matter as it produces negative pressure.

a)

True

b)

False

22.

The minimum size of the open vent pipe is?

a)

15mm

b)

22mm

c)

28mm

d)

35mm

23.

What type of heating system allows for some rooms in a property to be heated at the same time to a specific temperature?

a)

Selective central heating

b)

Background central heating

c)

Full central heating

d)

Specific central heating

24.

A background central heating system cannot heat on the same levels as full or selective heating systems. What does the background central heating system do instead?

a)

Heat the rooms hotter than desired

b)

Heat the pipes up to stop them from freezing

c)

Heat the rooms but at a lower temperature

25.

Which of the following does the 'Y-plan' system NOT accommodate?

a)

Full thermostatic control

b)

Building Regulations part L compliant

c)

Can be zone controlled

d)

Can be used with system boilers

26.

Building regulations cover conservation of fuel and power in existing dwellings in which section of part L?

a)

Part L1a

b)

Part L1b

c)

Part L2a

d)

Part L2b

27.

Which of the following would require replacing if these indications are present: 1) Lukewarm water in radiators.  2) Raditaors not heating up correctly.

a)

Essex flange

b)

Float operative valve

c)

Circulator pump

d)

Surrey flange

28.

What is the component shown?

a)

Spray can freeze kit

b)

Electric mains freezing kit

c)

Hole saw set

d)

Weir cup and pressure gauge set

29.

The process shown here is?

a)

Wiping any leaks from the flow pipe

b)

Polishing the radiator

c)

Covering any damage from the customer

d)

Bleeding the radiator

30.

How is the index radiator identified within the system?

a)

The radiator that gets hottest quickest

b)

The radiator that cools down first

c)

The radiator that heats up last in the system

d)

The radiator also known as 'heat sink'

31.

What is the tool shown here?

a)

Soft grip pliers

b)

Adjustable pump pliers

c)

Wide jaw adjustable spanner

d)

Stillson wrench

32.

Which of the following is not an advantage to using polybutylene pipes?

a)

High temperature resistance

b)

Low thermal expansion

c)

Low noise transmission

d)

High pressure resistance

33.

When a circulator is removed, what can be placed in is place temporarily?

a)

Another circulator

b)

A short piece of LCS pipe

c)

A piece of copper pipe

d)

None of the above

34.

Not only can a towel rail be used in a wet central heating system, but it can also run independently by?

a)

It's own central heating circuit

b)

Recycling bath hot water through the circuit

c)

An electrical element

d)

Turning on when the light is on

35.

Which installation is a space saver as the circulator, automatic bypass and an expansion vessel are included within the installation?

a)

Conventional gas boiler

b)

System gas boiler

c)

Gas combination boiler

d)

Unvented cylinder

36.

Of the following, where would a programmer be commonly situated?

a)

Front/Living room

b)

Kitchen

c)

In the hallway

d)

Near the front door

37.

What type of heating system allows all rooms in a property to be heated at the same time to a specific temperature?

a)

Selective central heating

b)

Background central heating

c)

Full central heating

d)

Specific central heating

38.

Of the following, which type of system would a pumped central heating system generally be?

a)

Two pipe system with circulator

b)

One pipe system with strainer

c)

Two pipe semi gravity

d)

C plan plus system

39.

Which of the following can be connection methods for radiator valves? (Choose 2)

a)

TTOE - Top, Top, Opposite Ends

b)

BBOE - Bottom, Bottom, Opposite Ends

c)

TBOE - Top, Bottom, Opposite Ends

d)

TTSE - Top, Top, Same Ends

40.

Which of the following is a system boiler?

a)

b)

c)