When performing an air temperature rise test you should let the appliance run at least how long?
5-10 minutes
10-15 minutes
15-20 minutes
20-30 minutes
When performing an air temperature rise the supply air temperature should be taken several feet away from _________________.
A supply outlet
radiator
return air intake
heat exchanger
If you are too close to the low end of the temperature rise, the air coming off the furnace will feel _______________.
to hot
to cold
just right
uneven
If you are too close to the low end of the temperature rise you may start to form________________.
Condensation
Steam
Heat
nothing at all.
When we are near or over the high-end of the temperature rise the furnace may begin cycling on and off the ________________.
Thermostat
Inducer motor
Flame sensor
Limit
When the temperature rise is too high, you are not moving enough air over the ________________.
Evaporator Coil
Thermostat
Heat Exchanger
Supply air outlet
You can estimate air flow by measuring _______ across the coil and the filter.
Temperature Rise
Static Pressure
Drops
Static Pressure
Airflow
When a cooling system is operated during low outdoor temperatures, the condensing _______ and head pressure will drop.
pressure
temperature
line
coil
Low _______ will often result in a partially frozen coil rather than a full block of ice.
Pressure
Temperature
Air Flow
Refrigerant
Low load is often due to low _______ ,low indoor ambient conditions and equipment oversizing.
Air Flow
Refrigerant
Suction Pressure
The outdoor coil on heat pump becomes the ___________ in heating mode.
Condenser
Evaporator
Metering Device
Blower Section
The first hard, fast rule when selecting a motor is going to be _______ and size
Horsepower
Capacitor Size
Frame
Shaft length
A good rule to follow when replacing a motor with an aftermarket motor is to keep the amp draw within + or - _______%
3
5
7
10
A 1075 rpm motor is ____ pole motor with a synchronous speed of 1200 rpm.
2
3
6
8
Blade position can be extremely important to condenser __________.
Air Flow
Operation
Condensing Temperatures
Condensing Pressures.
When replacing a motor always use the properly sized ___________.
horsepower
capacitor
amp draw
wire
High efficiency furnaces have a primary and (a) heat exchanger.
Cracks in a heat exchangers can cause ___________.
Soot
Condensation
High temperature rise
Carbon Monoxide