wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

4th Qtr Review

Total questions: 18

Worksheet time: 10mins

Name
Class
Date
1.

-+

When performing an air temperature rise test you should let the appliance run at least how long?

a)

5-10 minutes

b)

10-15 minutes

c)

15-20 minutes

d)

20-30 minutes

2.

When performing an air temperature rise the supply air temperature should be taken several feet away from _________________.

a)

A supply outlet

b)

radiator

c)

return air intake

d)

heat exchanger

3.

If you are too close to the low end of the temperature rise, the air coming off the furnace will feel _______________.

a)

to hot

b)

to cold

c)

just right

d)

uneven

4.

If you are too close to the low end of the temperature rise you may start to form________________.

a)

Condensation

b)

Steam

c)

Heat

d)

nothing at all.

5.

When we are near or over the high-end of the temperature rise the furnace may begin cycling on and off the ________________.

a)

Thermostat

b)

Inducer motor

c)

Flame sensor

d)

Limit

6.

When the temperature rise is too high, you are not moving enough air over the ________________.

a)

Evaporator Coil

b)

Thermostat

c)

Heat Exchanger

d)

Supply air outlet

7.

You can estimate air flow by measuring _______ across the coil and the filter.

a)

Temperature Rise

b)

Static Pressure

Drops

c)

Static Pressure

d)

Airflow

8.

When a cooling system is operated during low outdoor temperatures, the condensing _______ and head pressure will drop.

a)

pressure

b)

temperature

c)

line

d)

coil

9.

Low _______ will often result in a partially frozen coil rather than a full block of ice.

a)

Pressure

b)

Temperature

c)

Air Flow

d)

Refrigerant

10.

Low load is often due to low _______ ,low indoor ambient conditions and equipment oversizing.

a)

Air Flow

b)

Refrigerant

c)

Suction Pressure

11.

The outdoor coil on heat pump becomes the ___________ in heating mode.

a)

Condenser

b)

Evaporator

c)

Metering Device

d)

Blower Section

12.

The first hard, fast rule when selecting a motor is going to be _______ and size

a)

Horsepower

b)

Capacitor Size

c)

Frame

d)

Shaft length

13.

A good rule to follow when replacing a motor with an aftermarket motor is to keep the amp draw within + or - _______%

a)

3

b)

5

c)

7

d)

10

14.

A 1075 rpm motor is ____ pole motor with a synchronous speed of 1200 rpm.

a)

2

b)

3

c)

6

d)

8

15.

Blade position can be extremely important to condenser __________.

a)

Air Flow

b)

Operation

c)

Condensing Temperatures

d)

Condensing Pressures.

16.

When replacing a motor always use the properly sized ___________.

a)

horsepower

b)

capacitor

c)

amp draw

d)

wire

17.

High efficiency furnaces have a primary and (a)   heat exchanger.

18.

Cracks in a heat exchangers can cause ___________.

a)

Soot

b)

Condensation

c)

High temperature rise

d)

Carbon Monoxide