1.

A way of passage from one building to an area of refuge in another building on approximately the same level, or a way of passage through or around a fire barrier to an

area of refuge on approximately the same level in the same building that affords safety from fire and smoke originating from the area of incidence and areas communicating therewith.

a)

Horizontal Exit

b)

Exit Passageway

c)

Exit Enclosure

d)

Exit Corridor

2.

The minimum fire barriers separating areas or buildings, forming horizontal exits shall have

minimum of ................ fire resistance rating

a)

120 Min

b)

60 Min

c)

30 Min

d)

180 Min

3.

Every side of horizontal exit shall be led to stairway

or corridor, smoke-proof enclosure, or ramp leading to outside the building.

a)

True

b)

False

4.

The floor area on either side of a horizontal exit shall be sufficient to hold the

occupants of both floor areas, calculate the sufficient area given that the occupant load using the refugee is 200

a)

56 m2

b)

60 m2

c)

65 m2

d)

0.28 m2

5.

Access to an exit can be through kitchens, storerooms, or other rooms.

spaces subject to locking.

a)

True

b)

False

c)

6.

Ramps can be part of MOE (Means Of Egress)

a)

True

b)

False

c)

7.

Maximum rise of a single ramp run shall not exceed ....

a)

760 mm

b)

670 mm

c)

600 mm

d)

800 mm

8.

The minimum width of a ramp shall not be less than ...............mm.

a)

1200 mm

b)

1000 mm

c)

1500 mm

d)

1100 mm

9.

Ramps Landing can be less than the width of ramp

a)

True

b)

False

10.

Maximum slope of a ramp shall not exceed 1 in 12 ratio

a)

True

b)

False

11.

For non-sprinklered buildings, ........% of the required number of exits, and .....% of

the required egress capacity, shall discharge directly to outside the building

through yards, courts, open spaces or similar spaces to open to sky, leading to

public way or directly to a public way

a)

50/50

b)

50/100

c)

100/100

d)

100/50

12.

For an airport waiting area with an area of 1000 m2, calculate the following parameters to use in the life safety report:

1- Occupant load
2- Stair width

3-Ramp width

a)

1- 714 person

2- 5428 mm
3- 3570 mm

b)

1- 600 person

2- 4560 mm
3- 3000 mm

c)

1- 500 person

2- 3800 mm
3- 2500 mm

d)

1- 714person

2- 1200 mm
3- 900 mm

13.

Calculate the required total stair widths for an office with an area of 4650 m2

a)

3800 mm

b)

4500 mm

c)

500 mm

d)

1200 mm/

14.

Minimum number of Means of Egress for any building, floor, or story is

a)

2

b)

1

c)

3

d)

5

15.

The Dead end for basement and enclosed podium used only for parking and service rooms with sprinkler protection is

a)

15 m

b)

20 m

c)

30 m

d)

12 m

16.

The Travel distance for basement and enclosed podium used only for parking and service rooms with Non-Sprinkled protection is

a)

46 m

b)

61 m

c)

50 m

d)

66 m

17.

At Residential, Group A, B, C., Corridor shall be separated from other areas of the building by ........ fire resistance rated construction.

a)

60 min

b)

30 min

c)

120 min

d)

180 min

18.

In Residential, Group A, B, C. , Grilles and louvers shall be prohibited in walls or doors of exit access corridors.

a)

True

b)

False

19.

In Residential, Group A, B, C., Garbage chutes shall have 2 hour fire resistance rating.

a)

True

b)

False

20.

Commercial villas shall be separated from each other by a 1-hour fire resistance

rated construction.

a)

True

b)

False