wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Computed Radiography

Total questions: 20

Worksheet time: 2hrs 40mins

Name
Class
Date
1.

Which of the following components is NOT utilized for computed radiography (CR) system?

a)

Imaging plate reader

b)

Imaging plate

c)

Developer chemical

d)

Protective layer

2.

Which of the following material may be used in the construction of the computed radiography (CR) imaging plate outer cassette?

a)

Carbon fibers

b)

Lead

c)

Paper

d)

Stone

3.

Which of the following is the function of the conductive layer in the computed radiography (CR) imaging plate?

a)

Binding the phosphors to the phosphor layer.

b)

Increase electrostatic charge.

c)

Decreasing electrostatic charge.

d)

Binding the photons to the phosphor layer.

4.

Which layer of the computed radiography (CR) imaging plate prevents unwanted light and background radiation from affecting the unprocessed latent image?

a)

Conductor layer

b)

Light shield layer

c)

Support layer

d)

Color layer

5.

Which layer of the computed radiography (CR) imaging plate is responsible for creating the latent image from the transmitted x-ray photons exiting the patient?

a)

Protective layer

b)

Phosphor layer

c)

Conductive layer

d)

Light shield layer

6.

Which of the following options is the correct answer to the question: The phosphor layer of the computed radiography (CR) imaging plate is composed of _________?

a)

Barium Fluorohalides & Amorphous Selenium

b)

Amorphous Silicon & Europium Activator

c)

Barium Fluorohalides & Europium Activator

d)

Amorphous Silicon & Cesium Iodide

7.

What the term "latent image" refers to?

a)

Number of x-ray photons leaving the patient

b)

Interactions of the x-ray photons within the imaging plate

c)

Stored energy within the fluorohalides

d)

Release of energy from the fluorohalides

8.

What does the thin, active layer within the computed radiography (CR) cassette stored?

a)

Manifest image

b)

Patient's metadata

c)

Exam's metadata

d)

Latent Image

9.

What is another name for the conductive layer of a computed radiography (CR) imaging plate?

a)

Support layer

b)

Antistatic layer

c)

Base layer

d)

Static layer

10.

Which interaction occurs when an x-ray photon is absorbed by the phosphor layer of a computed radiography (CR) plate?

a)

Characteristic interaction

b)

Photoelectric interaction

c)

Compton interaction

d)

Classical interaction

11.

Which of the following materials is responsible for storing the latent image within the computed radiography (CR) imaging plate?

a)

Helium-neon

b)

Rare-earth metals

c)

Photo-stimulable phosphor (PSP)

d)

Amorphous selenium

12.

What is the name of the device that is needed to transfer the latent image within the imaging plate to a viewable digital radiograph?

a)

Gamma camera

b)

Linac

c)

Imaging plate reader (digitizer)

d)

Scintillator

13.

What is the purpose of the laser within the computed radiography (CR) reader (digitizer)?

a)

Release latent image from the photo-stimulable phosphor (PSP) layer

b)

Release latent image from the conductor layer

c)

Erase the latent image from the photo-stimulable phosphor (PSP) layer

d)

Erase the latent image from the support layer

14.

What is the role of the photomultiplier tube (PMT) within the

computed radiography (CR) reader system?

a)

Collect light photons

b)

Erase all latent image

c)

Release the latent image from the imaging plate

d)

Convert the analog data to a digital signal

15.

Hey Aria, Michael, and Abigail! Can you tell me what the primary function of the analog-to-digital converter (ADC) within the computed radiography (CR) plate reader is? Is it to convert:

a)

x-ray to light photons

b)

x-ray photons to electrical signal

c)

electrical signal to x-ray energy

d)

light photons to digital signal

16.

Which of the following component may be used in place of the photomultiplier tube to work faster within a CR reader system?

a)

a-Se

b)

TFT

c)

CCD

d)

ADC

17.

When should a computed radiography (CR) imaging plate be processed

to prevent loss of the latent image data?

a)

As soon after exposure as possible

b)

3 minutes after exposure

c)

5 minutes after exposure

d)

10 minutes after exposure

18.

Inside the CR reader, the laser will hit the imaging plate in

the zig-zag pattern known as ______________ pattern

a)

Symmetrical

b)

Plaster

c)

Blaster

d)

Raster

19.

Inside CR reader, after all the latent image is processed using the laser,

the image plate is completely erased by exposing the imaging plate to an intense ______________

a)

red light

b)

white light

c)

blue light

d)

green light

20.

What is an advantage of a photomultiplier tube (PMT) based CR plate reader as compared to charge-coupled device (CCD) type?

a)

increase imaging plate reading time

b)

increase sensitivity of the imaging plate reading

c)

increase the density and resolution of image produce

d)

increase the scattered radiation absorption