wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

GQ_Quiz_01_IRR_Rov

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

   IRR Scope and Application

a)

Architectural & civil/structural

b)

   Electronics

c)

   Sanitary & plumbing

d)

all of the choices

2.

  Contractor’s License law

a)

RA 4566

b)

    RA 4567

c)

RA 5466

d)

RA 5467

3.

Water Code of the Philippines

a)

PD 1067

b)

 PD 1607

c)

 RA 5466

d)

  PD 1706

4.

    What is NSCP means under IRR?

a)

  National Soil Conservation of the Philippines

b)

National Strategy Coding of the Philippines

c)

    National Statistical Cooperative Planning

d)

None of the choices

5.

Permit issued by the Building Official for accessory parts of the project with very special functions or use?

a)

Ancillary Permits

b)

  Special Permits

c)

Accessory Permits

d)

Specific Permits

6.

Architectural Drawings needed for Applications of Building permits

a)

Elevations, at least four (4), same scale as floor plan

b)

As-Built Plan

c)

Bubble Diagram

d)

All of the choices

7.

Standard width of title block for Building plans?

a)

40 mm

b)

5.0 cm

c)

40 cm

d)

50 mm

8.

Structural plans Drawing scale?

a)

not less than 1:100

b)

not less than 1:50

c)

not less than 1:20

d)

not less than 1:10

9.

Authorities who are expected to enforce their own regulations needed in processing the building permit, except this organization?

a)

  National Water Resources Board (NWRB)

b)

    Philippine Institute of Volcanology and Seismology (PHIVOLCS)

c)

Philippine National Police

 

d)

Philippine Ports Authority (PPA)

10.

Plumbing Law

a)

RA 1378

b)

RA 1738

c)

  RA 1728

d)

  RA 1348

11.

  Standard size of building permit sign board in residential buildings exclusive use of owners?

a)

900 mm x 600 mm

b)

Variable

c)

   100mm x 100mm

d)

1200mm x 900mm

12.

     Standard size of building permit sign board in commercial buildings?

a)

Variable width & Length

b)

500 Mts x 1.00 Mts

c)

10 mm x 20 mm

d)

1.0 cm x 25 cm

13.

    Type I Construction?

a)

   shall be steel, iron, concrete, or masonry construction

b)

shall be of wood construction

c)

  shall be steel, iron, concrete, or masonry construction

d)

shall be four-hour fire-resistive construction

14.

 IRR under rule 7 classification of buildings , what is Group B occupancy?

a)

Residentials, Hotels and Apartments

b)

  Residential building for the exclusive use of non-leasing occupants not exceeding 10 persons

c)

Residential building/structure for exclusive use of single-family occupants including school or company staff housing

d)

  All of the choices

15.

IRR under rule 7 classification of buildings, how many divisions for Group D only?

a)

3

b)

2

c)

6

d)

4