wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

ALE_Building Utilities Quiz 2

Total questions: 20

Worksheet time: 15mins

Name
Class
Date
1.

During elevator emergency, to rescue passengers, this part of the elevator is used to open

the doors from the outside.

a)

Panic Device

b)

Outside Door Latch

c)

Push Plate

2.

The simplest type of building automation system.

a)

Fire Alarm System

b)

Telecommunication System

c)

Sprinkler System

3.

A vent pipe connected to a vent stack.

a)

Elbow Vent

b)

Vent Thru Roof

c)

Circuit Vent

4.

Condensing unit is a part of a _________

a)

Refrigeration

b)

Mechanical Room

c)

Thermostat

5.

A faucet fitted with a nozzle curving downward used as a draw-off tap.

a)

Reducer

b)

Bibbcock

c)

Pipe Splitter

6.

Reference in measuring the depth of a trap seal of a trap.

a)

Top Dip to Crown Weir

b)

Calipher

c)

Dip Stick

7.

Minimum size of trap and waste branch for a pedestal urinal.

a)

1"

b)

3"

c)

6"

8.

Ratio of urinals for elementary school.

a)

1:25

b)

1:75

c)

1:30

9.

Minimum required number of water closets for female for office and public buildings

serving 55 occupants for employees.

a)

6

b)

8

c)

4

10.

Where there is exposure to skin contamination due to poisonous materials, what is the

ratio of lavatory to number of occupants.

a)

1:2

b)

1:5

c)

1:10

11.

How many days, at least, shall be given before any plumbing work inspection is done

after written notice for inspection.

a)

3 days

b)

1 week

c)

7 days

12.

Minimum time, in minutes, required for water to stay in the system or pipes for a water test without any leaks to satisfy said testing.

a)

30 minutes

b)

15 minutes

c)

45 minutes

13.

True or false, 60° branches or offsets may be used only when installed in a true vertical position.

a)

True

b)

False

14.

Cleanouts may be omitted on a horizontal drain less than 1.5 meters in length unless

such line is serving sinks or urinals, true or false.

a)

True

b)

False

15.

Maximum length of a tailpiece.

a)

300 mm

b)

600 mm

c)

150 mm

16.

Minimum extension of a vent stack through roof above any other vertical surface.

a)

150 mm

b)

200 mm

c)

300 mm

17.

Minimum number of stories served by a waste stack requiring a parallel ventstack.

a)

10

b)

20

c)

30

18.

The material used for filament in an incandescent bulb.

a)

Cathode

b)

Tungsten

c)

Lux

19.

On elevators, a gear-driven machine having a drum to which the wire ropes that hoist the

car are fastened, and on which they wind.

a)

Counter weight

b)

Guide Rails

c)

Winding-Drum Machine

20.

Under NBC, the clearance between the underside of the car and the bottom of the pit

shall not be less than ___.

a)

1000 mm

b)

600 mm

c)

300 mm