wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Cannock Fault finding DEC23

Total questions: 36

Worksheet time: 36mins

Name
Class
Date
1.

How would an inspector identify a SPD

is not ok to remain in service

a)

It will set of an alarm

b)

The indicator will turn Red

c)

It would keep tripping out

d)

It would smell of burning

2.

Which of the following would not be required in a fault finding sequence:

a)

time repair will take

b)

safe isolation

c)

testing

d)

analysis of results

3.

A continuity test as part of fault diagnosis would be carried out with which instrument:

a)

earth-fault loop impedance tester

b)

high resistance ohmmeter

c)

low resistance ohmmeter

d)

RCD tester

4.

The guidance for test leads used on instruments is contained in

a)

BS 7671

b)

EAWR

c)

HASAWA

d)

GS38

5.

Which dead test would be carried out during initial fault diagnosis

a)

RCD test

b)

insulation resistance

c)

functional

d)

earth-fault loop impedance

6.

Whilst fault finding you check and discover the BS 3036 fuse protecting the circuit has ruptured with globules of copper spattered over the holder together with black carbon powder. The most likely fault would be:

a)

short circuit

b)

open circuit

c)

loose termination

d)

broken conductor

7.

Whilst fault finding, you check and discover the BS 3036 fuse protecting the circuit has melted in the middle only. The most likely fault would be:

a)

open circuit

b)

short circuit

c)

loose termination

d)

overload

8.

A result of >100Ω on a continuity test would indicate what type of fault:

a)

none

b)

an insulation failure

c)

open circuit

d)

short circuit

9.

An RCD would protect against the following fault:

a)

open circuit

b)

overcurrent

c)

short circuit between live conductors

d)

short circuit between live conductors and earth

10.

The definition of isolation is

a)

Functional switching for normal operation

b)

Single pole devices connected in the phase conductor

c)

Removing from every source of electrical energy

d)

Isolating equipment from general mass of earth

11.

The item shown in the photo should be used in what process?

a)

Voltage measurement

b)

Socket polarity

c)

Calibration checks

d)

Safe isolation

12.

Which of the following is the most likely of implications caused from an exposed terminal?

a)

Electric shock to a person or livestock

b)

MCB operate

c)

RCD Operates

d)

Main Cut off fuse operates

13.

The safest method of ensuring that a system is safe to work on is?

a)

Follow the safe isolation procedure

b)

Isolate the installation at the main cut-out

c)

Use a fluke volt stick before you begin

d)

Place barriers at the distribution boards

14.

What is the benefit of using multi-hasp type padlock when isolating and locking off a circuit for maintenance?

a)

More than one circuit can be isolated at any one time

b)

Any single operative can make the circuit live once they have completed their task

c)

A circuit can only be made dead if all the operatives use locks

d)

More than one person can work on the circuit safely

15.

Which of the following is the most likely of implications caused from fault diagnostics

a)

Arcing

b)

Open circuit

c)

Loss of power

d)

Short circuit

16.

When should a Risk Assessment be carried out during the fault finding process

a)

When working around others

b)

Only when working at height

c)

Only when working Live

d)

Every time

17.

Which of the following could cause an SPD to operate

a)

Short circuit

b)

Lightning stikes in the area

c)

Overload in the circuit

d)

A damaged light switch

18.

Which of the following could cause an SPD to operate

a)

Short circuit

b)

Overload in the circuit

c)

Switching of large induction motors

d)

A damaged lamp

19.

Which of the following would be the most likely cause of the final light in a lighting circuit not working when the other lights do

a)

Short Circuit at the origin

b)

Open Circuit at the origin

c)

Open circuit in the last leg of the cable

d)

Short Circuit in the last leg of the cable

20.

Which logical stage should be carried first before carrying out fault diagnosis

a)

Gather information on Symptoms

b)

Rectify the work

c)

Safe isolation

d)

Functional testing

21.

Several test instruments are used on an installation, which of the following would be most likely to give a reading of 2.5kA?

a)

Low resistance ohmmeter

b)

Prospective fault current

c)

Insulation resistance tester

d)

RCD tester

22.

The main reason for the cross connecting the conductors during the ring final circuit test and not just relying on end to end reading is?

a)

To record the values in the R1+R2 box at the same time

b)

A more accurate R2 reading can be obtained

c)

To ensure that the circuit is clear of short circuits or earth faults

d)

To detect any interconnections in the circuit

23.

The accessory pictured is often used in testing when conducting test using what particular method?

a)

Test method 2

b)

Test method 1

c)

Continuity of ring final conductors

d)

Test method 3

24.

The following readings were taken on a test performed on a ring final circuit, Line to Line 0.8 Ω Neutral to Neutral 0.8 Ω cpc to cpc 0.8 Ω . What would be the expected reading between line and cpc at each socket outlet?

a)

1.6 Ω

b)

0.4 Ω

c)

0.8 Ω

d)

0.2 Ω

25.

If two bonding conductors or equal length were connected in parallel the resistance would

a)

Increase

b)

Double

c)

Not change

d)

Halve

26.

During a continuity of Ring final conductors test, 10 Sockets give a R1+R2 reading of 0.68 Ω, but one socket gives a reading of 0.92 Ω. What might that indicate?

a)

A spur on the circuit

b)

A trapped cpc in the back of the box

c)

A short circuit

d)

A high resistance fault

27.

A polarity test is conducted to verify that

a)

There is no breakdown of the insulation of the conductor

b)

The resistance is sufficiently low to operate the protective device within the specified time

c)

The circuit protection will operate within a pre-determined time

d)

Every protective and single pole device is connected in the line conductor only

28.

If 3 conductors equal in length and with a resistance of 1.5 Ω are connected in parallel, what is the total resistance?

a)

4.5 Ω

b)

0.5 Ω

c)

2 Ω

d)

15 Ω

29.

What is the formula for calculating earth fault loop impedance?

a)

Zs = Ze-(R1+R2)

b)

Zs = Ze+(R1+R2)

c)

Ze = Zs-(R1+R2)

d)

Zs = Zex(R1+R2)

30.

An RCD within a domestic is tripping intermittently, the most likely cause for this will be,

a)

a faulty appliance that is still plugged in

b)

a short circuit fault

c)

an overload

d)

a transient voltage

31.

During an inspection If there is a direct danger of an electric shock this would be coded as

a)

N/A

b)

Code 1

c)

Code 2

d)

Dangerous

32.

A client has reported power loss on an upstairs lighting circuit,

they have also heard noises from the loft.

What is the probable issue

a)

Faulty light fitting

b)

Power cuts in the area

c)

Rodent damage

d)

Faulty light switch

33.

Which sense would initially alert someone to a machine bearing starting to fail

a)

A sixth sense

b)

Sight

c)

Taste

d)

Hearing

34.

Is it acceptable to have a socket 2 M from the edge of the bath

a)

if its accessible by the use of a tool

b)

No

c)

Yes

d)

Only for specialist workers

35.

Fiber Optic cables can be damaged due to

a)

Using clips

b)

A tight bending radius

c)

Loud environments

d)

A bad atmosphere

36.

Some Automatic taps have stopped working in the staff toilets.

The power supply is confirmed healthy, what could the issue be?

a)

Circuit breaker tripped

b)

Supply authority issues

c)

Faulty solenoid

d)

Loss of neutral