X-ray photon energy is directly related to
I. Applied kilovoltage (kVp)
II. Applied milliamperes (mA)
III. Photon wavelength
I only
I and II only
I and III only
All of the above
Materials that emit light when stimulated by x-ray photons are called.
Ions
Electrodes
Phosphors
Crystals
Reduction in x-ray photon intensity as the photon passes through material is termed
Absorption
Scattering
Attenuation
Divergence
In comparison with 60kVp, 80 kVp will:
I. Permit greater exposure latitude
II. Produce longer-scale contrast
III. Produce more scattered radiation
I only
II only
I and II only
All of the above
Which of the following contributes to the radiographic contrast present on the finished radiograph?
I. atomic number of tissues radiographed
II. Any pathologic processes
III. Degree of muscle development
I and II only
I and III only
II and III only
All of the above
An increase in kilovoltage will have which of the following effects?
I. More scattered radiation will be produced
II. The exposure rate will increase
III. Radiographic contrast will increase
I only
I and II only
II and III only
All of the above
Which of the following groups of exposure factors will produce the shortest scale of contrast?
200 mA, 0.08s, 96 kVp, 12:1 grid
500mA, 0.03s, 70kVp, 8:1 grid
300mA, 0.05s, 95kVp, 8:1 grid
600mA, 1/40s, 70kVp, 6:1 grid
Which of the following factors influence/s the production of scattered radiation?
I. Kilovoltage level
II. Tissue density
III. Field size
1 only
1 and 2 only
1 and 3 only
1, 2, and 3
A 15% decrease in kilovoltage peak accompanied by a 50% increase in milliampere-seconds will result in a/an?
Shorter scale of contrast
Increase in exposure latitude
Increase in radiographic density
Decrease in recorded detail
Cassette front material can be made of which of the following?
I. Carbon fiber
II. Magnesium
III. Lead
1 only
1 and 2 only
1 and 3 only
all of the above
The continued emission of light by a phosphor after the activating source has ceased is termed.
Fluorescence
Phosphorescence
Image intensification
Quantum mottle
Which of the following materials may be used as grid interspace material?
I. Lead
II. Plastic
III. Aluminum
I only
I and II only
II and III only
all of the above
An increase in the kilovoltage applied to the x-ray tube increases the:
I. x-ray wavelength
II. Exposure rate
III. Patient absorption
. I only
II only
II and III only
All of the above
What are the effects of scattered radiation on a radiographic image?
I. It produces fog
II. It increases contrast.
III. It increases grid cutoff
. I only
II only
I and II only
all of the above
Methods that help to reduce the production of scattered radiation include using:
I. compression
II. beam restriction
III. a grid
I and II only
I and III only
II and III only
all of the above
Which of the following affect/s both the quantity and quality of the primary beam?
Half-value layer (HVL)
Peak kilovoltage (kVp)
Milliamperage (mA)
All of the above
The exposure factors of 400mA, 17ms, and 82 kVp produce a milliampere-seconds value of
2.35
6.8
23.5
68
The radiographic accessory used to measure the thickness of body parts in order to determine optimal selection of exposure factors is the
Fulcrum
Caliper
Densitometer
Ruler
An increase in kilovoltage will serve to
produce a longer scale of contrast
produce a shorter scale of contrast
decrease the radiographic density
. decrease the production of scattered radiation
Which of the following is/are associated with subject contrast?
I. Patient thickness
II. Tissue density
III. Kilovoltage
I only
I and II only
I and III only
all of the above
The relationship between the height of a grid’s lead strips and the distance between them is referred to as grid:
Ratio
Radius
Frequency
Focusing distance
A decrease in peak kilovoltage will result in
decrease in optical density
decrease in contrast
decrease in recorded detail
. decrease in image resolution
Which of the following may be used to reduce the effect of scattered radiation on a finished radiograph?
I. Grids
II. Collimators
III. Compression bands
I only
I and III only
II and III only
all of the above
If a particular grid has lead strips 0.40mm thick, 4.0mm high, and 0.25mm apart, what is its grid ratio?
8:1
10:1
12:1
16:1
It is a measure of the degree of film darkening, depending on the number of x-rays reaching the film.
Density
Contrast
kVp
mAs
A device that converts x-ray energy into visible light.
Intensifying screen
Film
Collimator
Grid
Ability to image two separate objects and visually distinguish one from the other.
Resolution
Contrast Resolution
Spatial Resolution
Noise
Ability to image small objects that have high subject contrast.
Resolution
Contrast Resolution
Spatial Resolution
Noise
Ability to distinguish anatomical structures of similar subject contrast.
Resolution
Contrast Resolution
Spatial Resolution
Noise
If a particular grid has lead strips 1mm thick, 5.0mm high, and 0.5mm apart, what is its grid ratio?
3:1
5:1
10:1
16:1
The RT used 75 kVp and 3.2 mAs; what would be the new kVp and mAs if the RT wanted to decrease the patient dose but with the same density output.
86.25 kVp and 1.6 mAs
63.75 kVp and 6.4 mAs
Both A and B
None of the above
The RT used 75 kVp and 3.2 mAs; what would be the new kVp and mAs if the RT wanted the same density output.
86.25 kVp and 1.6 mAs
63.75 kVp and 6.4 mAs
Both A and B
None of the above
The RT used 70 kVp and 4.5 mAs; what would be the new kVp and mAs if the RT wanted to increase the density output.
80.5 kVp and 2.25 mAs
59.5 kVp and 9 mAs
Both A and B
None of the Above
If 30 mA was applied using 1/5 exposure time, what will be the mAs?
6 mAs
5.9 mAs
Both A and B
None of the Above
It is inherent in screen-film combination and influenced by film processing.
Radiographic Contrast
Image Receptor contrast
Subject contrast
None of the above
It is determined by size, shape and mass density of the anatomy that is being examined and the energy of the x-ray beam.
Radiographic contrast
Image receptor contrast
Subject contrast
None of the above
The product of image receptor contrast & subject contrast.
Radiographic contrast
Image receptor contrast
Subject contrast
None of the above
What is radiographic density?
It is a measure of the degree of film darkening
Optical Density
Film Density
All of the above
All factors shown below affect the radiographic contrast: EXCEPT.
mAs
Processing time
Patient Thickness
Film Speed
All factors shown below affect the radiographic contrast: EXCEPT.
mAs
Processing Time
Patient Thickness
Magnification
Device used to reduce the intensity of scatter radiation in the x-ray beam.
Grid
Collimator
Beam Restrictor
All of the Above
A device that converts the energy of the x-ray beam into visible light.
Screen Film
Intensifying Screen
Both A and B
None of the Above
All are layers of the Intensifying Screen; EXCEPT
Protective Layer
Adhesive Layer
Phosphor Layer
Reflective Layer
It is a physical characteristic of development.
Time
Temperature
Concentration of the developer
All of the Above
It is the final step in processing film.
Developing
Fixing
Drying
None of the above
Transport system of the automatic processor starts at the?
Feed tray
Entrance Roller
Transport Rack
Both A and B
It controls processing by controlling the time the film is immersed in each wet chemical
Feed tray
Entrance Roller
Transport System
Both A and B
The most important factor that influences subject contrast.
kVp
Kilovoltage peak
Time
Both A and B
Using a Low kVp will result in what kind of contrast?
Short Scale Contrast
High Subject Contrast
Long gray scale contrast
Both A and B
There are few density steps and the difference in blackness is significant.
Short Scale Contrast
High Subject Contrast
Long gray scale contrast
Both A and B
Have more discernible shades of gray, and therefore the differences between adjacent shades of gray are smaller.
Short Scale Contrast
High Subject Contrast
Long gray scale contrast
Both A and B
It affects the exposure to the IR because it alters the amount and penetrating ability of the x-ray beam.
kVp
kilovoltage peak
Time
Both A and B
A larger potential difference occurs in the x-ray tube, giving more electrons the kinetic energy to produce x-rays and increasing the kinetic energy overall.
An increase in exposure time
An increase in kVp
An increase in mAs
Both A and B
It controls the number of X-Rays.
mAs
milli amperes per second
exposure time
Both A and B
All are long scale contrast, EXCEPT
Chest Xray
Abdomen Xray
Pelvis Xray
Both A and B
All are short scale contrast, EXCEPT
Chest Xray
Abdomen Xray
Pelvis Xray
Both A and B
It is the unequal magnification of different portions of the same object.
Magnification
Distortion
Focal-spot Blur
None of the Above
It is the unequal magnification of different portions of the same object.
Magnification
Distortion
Focal-spot Blur
None of the Above
The most important factor in determining spatial resolution.
Magnification
Distortion
Focal-spot Blur
None of the Above
Which of the following are methods of limiting the production of scattered radiation?
1) Using moderate ratio grids
2) Using prone position for abdominal examinations
3) Restricting the field size to the smallest practical size
1 and 2 only
1 and 3 only
2 and 3 only
1, 2, and 3
Which of the following groups of exposure factors will produce the least radiographic density?
100 mA, 50ms
200 mA, 40ms
200 mA, 50ms
600 mA, 30ms
To be suitable for use in intensifying screens, a. phosphor should have which of the following characteristics?
1. High conversion efficiency
2. High x-ray absorption
3. High atomic number
1 only
3 only
1 and 2 only
1, 2, and 3
In radiography of a large abdomen, which of the following is (are) effective way (s) to minimize the amount of scattered radiation reaching the image receptor?
1. Use of close collimation
2. Use of compression device
3. Use of a low-ratio grid
1 only
1 and 2 only
1 and 3 only
1, 2, and 3
When blue-emitting rare earth screens are matched properly with the correct film emulsion, what type of safelight should be used in the darkroom?
1. Red
2. GBX-2
3. Ultraviolet
1 only
1 and 2 only
1 and 3 only
1, 2, and 3
Misalignment of the tube-part-IR relationship results in?
Shape distortion
Maze Distortion
Magnification
Blur
SID affects recorded detail in which of the following ways?
Recorded detail is directly related to SID.
Recorded detail is inversely related to SID.
As SID increases, recorded detail decreases
SID is not a detail factor
Of the following groups of exposure factors, which will produce the least radiographic density?
400 mA, 30ms, 72-inch SID
200 mA, 30ms, 36-inch SID
200 mA, 60ms, 36-inch SID
400 mA, 60ms, 72-inch SID
Which of the following pathologic conditions would require a decrease in exposure factors?
Pleural Effusion
Osteopetrosis
Ascites
Tuberculosis
Tuberculosis
Developer, wash, fixer, dry
Fixer, wash, developer, dry
Developer, fixer, wash, dry
Fixer, developer, wash, dry
Which of the following groups of exposure factors would be most appropriate to control involuntary motion?
400 mA, 0.03 s
200 mA, 0.06 s
600 mA, 0.02 s
100 mA, 0.12 s
A wire-mesh test is performed to evaluate screen
lag
contact
resolution
intensification
Why is a very short exposure time essential in chest radiography
To avoid excessive focal-spot blur
To maintain short-scale contrast
To minimize involuntary motion
To minimize patient discomfort
Film base is currently made of which of the following materials?
Cellulose nitrate
Cellulose Triacetate
Polyester
Glass plate
To produce a just perceptible increase in radiographic density, the radiographer must increase the?
mAs by 30 percent
mAs by 15 percent
kVp by 15 percent
kVp by 30 percent
Which of the following chemicals is used in the production of radiographic film emulsion?
Sodium sulfite
Potassium bromide
Silver halide
Chrome alum
Which of the following terms refer to light being reflected from one intensifying screen, through the film, to the opposite emulsion and screen?
Reflectance
Crossover
Scatter
Filtration
If 0.05s was selected for a particular exposure, what milliamperage would be necessary to produce 30 mAs?
900
600
500
300
Which of the following pathologic conditions would require an increase in exposure factors?
Pneumoperitoneum
Obstructed bowel
Renal Colic
Ascites
Part of IS that serves as mechanical support for phosphor and is farthest from the film.
Base
Reflective layer
Protective layer
Adhesive layer
Factors affecting film speed
1. Number of Silver halide crystals
2. Number of sensitivity center per crystals
3. Size and distribution of crystals
4. Concentration of crystals in the phosphor
1 and 2
2 and 3
1, 2, and 3
All of the above
What information, located on each box of film, is important to note and has a direct relationship to image quality?
Number of films in the box
Manufacturer’s name
Expiration date
Emulsion lot
Increasing field size from 8x10 inches to 14x17 inches, with no other changes, will
Decrease density; decrease scattered radiation
Decrease density; increase the scattered radiation
Increase density; increase scattered radiation
Increase density; decrease scattered radiation
The following are used to reduce motion blur, except:
1. Use of shortest possible exposure time
2. Use of small SID
3. Use of restraining device
4. Use of large OID.
1 and 2
2 and 3
2 and 4
1 and 4
Which of the following is an abnormal intensifying screen action?
Fluorescence
Luminescence
Speed
Lag
A device that converts x-ray energy into visible light.
Intensifying screen
Film
Collimator
GrIS
Ability to image two separate objects and visually distinguish one from the other.
Resolution
Contrast Resolution
Spatial Resolution
Noise
Ability to image small objects that have high subject contrast.
Resolution
Contrast Resolution
Spatial Resolution
Noise
Ability to distinguish anatomical structures of similar subject contrast.
Resolution
Contrast Resolution
Spatial Resolution
Noise
If a particular grid has lead strips 1mm thick, 5.0mm high, and 0.5mm apart, what is its grid ratio?
3:1
5:1
10:1
16:1
Device used to reduce the intensity of scatter radiation in the x-ray beam.
Grid
Collimator
Beam restrictor
All of the above
Device used to reduce the intensity of scatter radiation in the remnant x-ray beam.
Grid
Collimator
Beam restrictor
All of the above
A device that converts the energy of the x-ray beam into visible light.
Screen film
Intensifying Screen
Both A and B
None of the above
All are layers of the Intensifying Screen; EXCEPT
Protective layer
Adhesive layer
Phosphor layer
Reflective layer
It is a physical characteristic of development.
Time
Temperature
Concentration of the developer
All of the above
The darkroom must :
Not allow white light to enter
Have a secured entrance
Have an appropriate safe lighting
All of the above
Designed to prevent/protect film from exposure to white light and ionizing radiation during handling and processing.
Dark room
Processing room
Exposure room
All of the above
The darkroom must have a protective wall;
Concrete less than 6 inches
Concrete greater than 6 inches
6 inches hollow blocks
Wood with 1.15mm Pb
It allows the film to transfer without entering the darkroom.
Passbox
Film cassette transfer cabinet
A only
Both A and B
Source of overhead lighting for general purposes.
White light illumination
Safe light illumination
Overhead illumination
Both A and C
Source of overhead lighting for general purposes.
White light illumination
Safe light illumination
Overhead illumination
Both A and C
Purpose of white light illumination.
Maintenance
Loading and unloading of film
Processing
Both A and C
Protects the emulsion from scratches, pressure and contamination during handling, processing and storage.
Supercoating
Overcoating
Protective coating
All of the above
Prevents glare when a finished radiograph is viewed.
Supercoating
Emulsion
Adhesive Layer
Base
It allows emulsion & base to maintain proper contact & integrity.
Supercoating
Emulsion
Adhesive Layer
Base
It maintains its size and shape of film during use and processing.
Supercoating
Emulsion
Adhesive Layer
Base
Factors affecting detail and distortion.
SID
OID
SOD
All of the above
It is the distance between the radiation side of the test object and the film surface, measured along the central axis of the radiation beam.
SID
OID
SOD
All of the above
It is the distance between the radiation source and the radiographic film.
SID
OID
SOD
All of the above
It Is the distance between the radiation side of the object and the film/cassette surface.
SID
OID
SOD
All of the above
Focal spot blur is less on what side?
Anode
Cathode
Both A and B
None of the above
High speed intensifying screens produce what kind of image. EXCEPT.
High spatial resolution
Low spatial resolution
Inherent of quantum mottle
Both B and C
Reflective layer increases?
Speed
Blur
Spatial resolution
Both A and B
If the source to the object distance is increased, the magnification would?
Decrease
Increase
Both A and B
None of the above
If the film to the object distance is increased, the magnification would?
Decrease
Increase
Both A and B
None of the above
If the source to the image distance is increased, the magnification would?
Decreases
Increases
Both A and B
None of the above
Poor screen contact will result in what kind of image?
Low contrast resolution
Low spatial resolution
Both A and B
None of the above
It is used when spatial resolution is important.
Large focal spot
Small focal spot
Both A and B
None of the above
What is the focal spot size commonly used in general radiography?
1.0 mm
1.2 mm
1.0 cm
Both B and C
What is the thickness of the emulsion?
1-2 um
3-5 um
5-6 um
6-8 um
What is the percentage of the silver bromide in the emulsion layer?
98%
2%
10%
Both B and C
What is the percentage of the silver bromide in the emulsion layer?
98%
2%
10%
Both B and C
As the number of SHC increases the _____ also increases.
Film sensitivity
Patient Dose
Spatial resolution
All of the above
What is the relationship between contrast and latitude?
Directly proportional
Inversely proportional
No change at all
All of the above
A long scale contrast have/has?
High kVp
High latitude
Many shades of gray
All of the above
This is used to transport film for use without exposing the film to room light.
Cassette
Film Holder
Pass box
Both A and B
The light emitted must be of proper wavelength (color) to match the film sensitivity.
Conversion Efficiency
Detective Quantum Efficiency
Quantum mottle
Spectral matching
If the radiologic technologist used a green sensitive intensifying screen with blue sensitive film, what would be the result of the radiograph?
Under exposed
Over exposed
Normal exposure
None of the above