Worksheets

Boosted Cold Water Systems L3P1.U5.LO2.1.p3.

Total questions: 10

Worksheet time: 5mins

Name
Class
Date
1.

What is the purpose of a break cistern in the indirect boosted to a storage cistern system?

a)

To provide a 'break' between the mains cold water and the system it is supplying

b)

To store water before it is boosted to the system

c)

To filter the air vent

d)

To control the water level in the high-level cistern

2.

What is the range of pressure for mains cold supplies in the UK?

a)

1bar to 4bar

b)

5bar to 8bar

c)

2bar to 5bar

d)

3bar to 7bar

3.

What is the purpose of a float switch in the high-level cistern?

a)

To control the pump when the water level drops

b)

To prevent insects and vermin from entering the cistern

c)

To increase the water pressure

d)

To control the water temperature

4.

What is the maximum flow rate output that the break cistern should be able to store?

a)

15 minutes of pumps maximum flow rate output

b)

30 minutes of pumps maximum flow rate output

c)

10 minutes of pumps maximum flow rate output

d)

20 minutes of pumps maximum flow rate output

5.

What is the purpose of the pipeline switch in the header by-pass?

a)

To start the pumps when the water level in the header falls

b)

To control the water level in the high-level cistern

c)

To filter the air vent

d)

To prevent insects and vermin from entering the cistern

6.

What is the purpose of the boosted cold water system?

a)

To store water before it is boosted to the system

b)

To increase the water pressure

c)

To control the water temperature

d)

To lift the water to a cistern for distribution to the outlets below

7.

What is the function of the high-level cisterns in the boosted cold water system?

a)

To supply drinking water only

b)

To filter the air vent

c)

To control the water temperature

d)

To supply non-drinking water only

8.

What is the purpose of the direct boosted to a drinking water header or cistern system?

a)

To supply the dwellings with drinking water when the pumps are not in operation

b)

To store water before it is boosted to the system

c)

To control the water level in the high-level cistern

d)

To increase the water pressure

9.

What is the purpose of the water supply (water fittings) regulations?

a)

To forbid pumping direct from a mains supply when the flow rate is greater than 12 litres per minute without prior consent

b)

To increase the water pressure

c)

To control the water temperature

d)

To store water before it is boosted to the system

10.

What is the purpose of the boosting pump in a multi-storey building?

a)

To lift the water, usually to a cistern, for distribution to the outlets below

b)

To control the water temperature

c)

To store water before it is boosted to the system

d)

To increase the water pressure