Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical Exam Help Quiz

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

What is the adiabatic equation used to calculate?

a)

Voltage drop

b)

Size of a protective conductor

c)

Rating factors

d)

Cable grouping

2.

What does the symbol 's' represent in the adiabatic equation?

a)

Cable factor

b)

Fault current

c)

Operating time of the fuse or breaker

d)

Size of the conductor

3.

What is the maximum permitted voltage drop for lighting circuits at 230 volts?

a)

12 volts

b)

9 volts

c)

6 volts

d)

3 volts

4.

What does the symbol 'mvam' represent in the voltage drop formula?

a)

Length of the circuit in meters

b)

Design current of the attached equipment

c)

Millivolts drop in the cable

d)

Voltage drop in the circuit

5.

Where can the rating factor tables for various cable conditions be found?

a)

Page 383

b)

Page 409

c)

Page 196

d)

Page 373

6.

What does the symbol 'i t' represent in the cable size calculation formula?

a)

Tabulated current

b)

Tabulated voltage drop

c)

Tabulated size

d)

Tabulated cable factor

7.

What does the rating factor 'cg' represent in cable grouping?

a)

Ambient air temperature

b)

Derating factor

c)

Cable arrangement

d)

Number of cables grouped together

8.

What is the tabulated current rating for a cable bunched in a group of four in air?

a)

19.38 amps

b)

17.38 amps

c)

15.38 amps

d)

13.38 amps

9.

What cable size should be chosen to carry a 20 amp load in a ceiling void at 40 degrees centigrade?

a)

10 millimeter cable

b)

4 millimeter cable

c)

2.5 millimeter cable

d)

6 millimeter cable

10.

What is the maximum permitted voltage drop for all other circuits at 230 volts?

a)

3 volts

b)

6 volts

c)

9 volts

d)

12 volts

11.

What does the symbol 'k' represent in the adiabatic equation?

a)

Fault current

b)

Operating time of the fuse or breaker

c)

Size of the conductor

d)

Cable factor

12.

Where can the table for twin and earth cable be found in the wiring regulations book?

a)

Page 409

b)

Page 196

c)

Page 383

d)

Page 373

13.

What is the tabulated current rating for a cable bunched in a group of five in air?

a)

21.73 amps

b)

19.73 amps

c)

17.73 amps

d)

15.73 amps

14.

What cable size should be chosen to carry a 10 amp load in a ceiling void at 35 degrees centigrade?

a)

2.5 millimeter cable

b)

4 millimeter cable

c)

6 millimeter cable

d)

10 millimeter cable

15.

What is the maximum permitted voltage drop for lighting circuits at 230 volts?

a)

3 volts

b)

6 volts

c)

9 volts

d)

12 volts