Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

GMJ 9189 Phase 2 Hot water MCQ

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

Identify this item.

a)

Fullway gate valve

b)

Drain off valve

c)

Part 2 float operated valve

d)

Stop valve

2.

What chemical is used in the disinfecting process of a hot water system?

a)

Sodium peroxide

b)

Sodium hypochlorite

c)

Hydrochloric acid

d)

Caustic soda

3.

Where on a domestic hot water cylinder should the cold feed be connected?

a)

Bottom

b)

Top

c)

Middle

d)

A third of the way up

4.

Which is the best description of category 1 water?

a)

Water stored at 600C

b)

Wholesome water

c)

Water that offers a slight health risk

d)

Water that has a mild chemical added

5.

What device is used to protect category 1 water from being contaminated by category 2 water?

a)

RPZ valve

b)

AUK1 air gap

c)

Single check valve

d)

AG air gap

6.

What is this item called?

a)

Expansion vessel

b)

Tundish

c)

Strainer

d)

Pressure reducing valve

7.

What does WRAS stand for?

a)

Water Revival Advanced Scheme

b)

Winter Regulations and Spring

c)

Water Regulations Advisory Scheme

d)

Water Ripples and Systems

8.

What air gap is used at a kitchen sink to protect category 1 water?

a)

AUK1

b)

AUK2

c)

AUK3

d)

AG

9.

What sort of tap would be best suited for an elderly person with arthritis?

a)

Bib tap

b)

Long neck pillar tap

c)

Non-rising tap

d)

Quarter turn tap

10.

If there is a faulty fullway gate valve in the system, what should you do?

a)

Replace the back nut to release the fault

b)

Replace the body of the valve and leave the head gear

c)

Lubricate the body to release the fault

d)

Replace the whole valve

11.

Which Building Regulation states that one of these valves must be fitted before the outlet on any new bath fitted?

a)

Part H

b)

Part L

c)

Part G

d)

Part P

12.

Which British Standard is used alongside BSEN806 and covers the design, installation, testing and maintenance of servicing supplies for domestic use?

a)

BS8558

b)

BS8000

c)

BS12056

d)

BS1212

13.

Which one of the following systems can this appliance be connected to?

a)

Low pressure system fed from a cold-water storage cistern

b)

Thermal store heater

c)

Single point water heater

d)

Unvented hot water system

14.

If a hot water appliance had a fault, where would you look for guidance?

a)

BSEN806

b)

The Water Supply (Water Fittings) Regulations

c)

The manufacturer's instructions

d)

Building Regulations Part L

15.

What must happen to any open-ended pipework when a system is being decommissioned?

a)

It should be labelled 'not in use'

b)

It should be capped off

c)

It should be re-connected to the appliance

d)

The customer should be advised not to use it

16.

What does this diagram show?

a)

Electric shower

b)

Double impeller shower

c)

Gravity shower

d)

Single impeller shower

17.

What type of hot water system is shown in this diagram?

a)

Low pressure gravity system

b)

Thermal store hot water system

c)

Unvented hot water system

d)

Primatic hot water system

18.

Which of the following is not a statutory source of information?

a)

Building Regulations Part L

b)

The Water Supply (Water Fittings) Regulations

c)

BSEN806

d)

Approved Document Part G

19.

What backflow prevention device is being used to protect the wholesome water against contamination in this shower valve?

a)

Double check valve

b)

AUK2 air gap

c)

Single check valve

d)

RPZ valve

20.

What is meant by the term ‘heat recovery’?

a)

The time taken for the boiler to get to temperature

b)

The time taken to heat up a full cylinder of hot water

c)

The time take for the primaries to start heating the cylinder

d)

The time taken for the cylinder thermostat to activate the boiler