1.

A type of conduit that has a wall thickness less than that of RMC but thicker than EMT is

a)

PVC

b)

HDPE

c)

IMC

d)

LFNC

2.

A type of fastener with a bugle-shaped head is a _____.

a)

drywall screw

b)

drive screw

c)

thread-forming screw

d)

lag screw

3.

Wire bundles are commonly secured using _____.

a)

electrical tape

b)

Teflon tape

c)

elastic cords

d)

tie wraps

4.

Another name for a standoff support is a _____.

a)

Minerallac®

b)

clamp back

c)

beam clamp

d)

trapeze

5.

NEC Article 344 provides the requirements for _____.

a)

PVC

b)

EMT

c)

IMC

d)

RMC

6.

The purpose of a sealing fitting is to _____.

a)

carry wires through conduit and other types of raceways

b)

bundle wires and cables together

c)

connect conduit to boxes

d)

minimizes the passage of gases, vapors, and flames through a conduit

7.

When transporting long lengths of raceway to the jobsite, _____.

a)

flag the ends

b)

paint the ends orange

c)

the raceway may be cut to shorter lengths to fit in the truck

d)

secure the load in the center rather than on both ends

8.

Cable trays are covered in _____.

a)

NEC Article 344

b)

NEC Article 355

c)

NEC Article 376

d)

NEC Article 392

9.

When installing conduit in reinforced concrete, it is best to use a(n) _____.

a)

standard device box

b)

utility box with a raised device cover

c)

concrete box with ears

d)

conduit body

10.

Conduit that passes from a classified location into an unclassified location requires the use of a(n) _____.

a)

nylon fitting

b)

PVC fitting

c)

standard entrance elbow

d)

sealing fitting

11.

The voltage drop of conductors carrying alternating current in PVC will be less than that of identical conductors in _____.

a)

steel conduit

b)

plastic conduit

c)

LFNC

d)

HDPE

12.

EMT is _____.

a)

steel conduit coated with a black enamel

b)

conduit that is constructed of metal thick enough to permit the cutting of pipe threads at each end

c)

often referred to as thinwall conduit and too thin to be threaded

d)

conduit that has been given a thin coating of PVC

13.

A typical metric fastener size is _____.

a)

M8 × 1

b)

3.4M

c)

10 UNC

d)

10 LH

14.

A type of conduit body with a 90° connector and the cover on the left is a _____.

a)

Type LL

b)

Type LB

c)

Type LR

d)

Type LT

15.

EMT must be supported every _____.

a)

4' (1.2 m)

b)

5' (1.5 m)

c)

10' (3 m)

d)

15' (4.5 m)

16.

NEC Article 386 contains _____.

a)

the installation specifications of surface metal raceways

b)

information on multi-outlet assemblies

c)

regulations for combination raceways

d)

a list of the various types of special raceways

17.

The type of anchor shown in the figure above is a _____.

a)

drop-in anchor

b)

drive-in anchor

c)

toggle bolt

d)

self-drilling anchor

18.

One characteristic of aluminum conduit is that it _____.

a)

requires more maintenance

b)

is too thin to be threaded

c)

does not require supplementary corrosion protection when used in concrete

d)

is more resistant to wet environments

19.

When an equipment frame is bonded to metal conduit, it acts as the equipment _____.

a)

neutral

b)

grounding conductor

c)

high leg

d)

ungrounded conductor

20.

The maximum allowable spacing between horizontal wireway supports is _____.

a)

8' (2.5 m)

b)

10' (3 m)

c)

15' (4.5 m)

d)

20' (6 m)

21.

The highest power level for a powder-actuated device is _____.

a)

1

b)

5

c)

10

d)

12

22.

When installing hammer-driven pins and studs in soft concrete block, the drive pin or stud should be embedded in the concrete for at least _____.

a)

1/2" (13 mm)

b)

5/8" (16 mm)

c)

3/4" (19 mm)

d)

1-1/4" (32 mm)

23.

Derating factors shall only be applied when the number of current-carrying conductors in a wireway exceeds _____.

a)

15

b)

20

c)

25

d)

30

24.

To act as a moisture seal, an outer covering of liquidtight, sunlight-resistant flexible material is placed around _____.

a)

flexible nonmetallic conduit

b)

flexible metal conduit

c)

high-density polyethylene conduit

d)

rigid polyvinyl chloride conduit

25.

Cable trays mounted in a tunnel are most likely to use _____.

a)

pipe rack mounting

b)

wall mounting

c)

trapeze mounting

d)

direct rod suspension

26.

Conduit is best stored _____.

a)

in loose piles sorted by size

b)

unsealed to prevent bulging due to temperature changes

c)

in pipe racks

d)

outdoors to become acclimated to the ambient temperature

27.

When using an epoxy anchoring system, _____.

a)

tighten the fastener nut to secure the component before the epoxy sets

b)

always use a wire brush to clean the prepared hole

c)

the epoxy should be striped rather than uniform in color

d)

use an anchor screen in hollow wall or brick

28.

A type of anchor that is a good choice when jacking or leveling the fastening component is a(n) _____.

a)

wedge anchor

b)

stud bolt anchor

c)

one-piece anchor

d)

hammer-set anchor

29.

When making a conduit-to-box connection and a bonding wire will be installed, use a _____.

a)

standard locknut

b)

sealing locknut

c)

grounding locknut

d)

plastic locknut

30.

A type of fitting used to prevent damage to PVC caused by temperature changes is a(n)

a)

combination coupling

b)

flex connector

c)

hinged coupling

d)

expansion coupling

31.

Which type of conduit is known for its flexibility and is often used in areas with vibration?

a)

EMT

b)

LFMC

c)

PVC

d)

RMC

32.

When installing a conduit system in a corrosive environment, it is best to use _____.

a)

aluminum conduit

b)

PVC-coated conduit

c)

galvanized steel conduit

d)

stainless steel conduit

33.

The primary purpose of a junction box is to _____.

a)

serve as a conduit support

b)

house electrical panels

c)

protect wire connections

d)

support lighting fixtures