WorksheetsPD1096
Total questions: 30
Worksheet time: 15mins
Maximum horizontal distance of court and yards.
2 meters
2.5 meters
1.5 meters
3 meters
minimum wind load capacity for roof
150 kg/sqm
120 kg/sqm
200 kg/sqm
175 kg/sqm
minimum wind load capacity for ground floor level
150 kg/sqm
120 kg/sqm
200 kg/sqm
175 kg/sqm
minimum floor live load at succeeding upper floors
150 kg/sqm
120 kg/sqm
200 kg/sqm
175 kg/sqm
minimum width of every stairs in group A dwellings
1000mm
900mm
750mm
500mm
the required open spaces left after deducting the outermost face of the building
setback
fence
open space
yard
minimum thickness of foundation footings on dwelling units
500mm
300mm
250mm
200mm
minimum depth below the ground of foundation footings on dwelling units
250mm
600mm
500mm
1000mm
minimum ceiling height for artificially ventilated rooms on first storey
2.70m
2.90m
3.00m
2.50m
minimum ceiling height for artificially ventilated rooms on succeeding upper storeys
2.40m
3.00m
2.70m
2.90m
minimum height of mezzanine floors
2.50m
1.80m
2.40m
2.70m
minimum area of rooms for habitation
25 sqm
10 sqm
6 sqm
15 sqm
minimum dimension of room for habitation
3m
2m
5m
6m
minimum area for kitchen
5 sqm
3 sqm
12 sqm
1.5 sqm
minimum dimension for kitchen
3m
2m
1.5m
2.5m
minimum area for toilet and bath
3 sqm
1.2 sqm
2.5 sqm
5 sqm
minimum dimension for toilet and bath
0.90 m
1.00 m
0.75 m
1.2 m
minimum clearance of window openings, eaves or canopies to side and rear property lines
500mm
1000mm
900mm
750mm
minimum bottom openings for windows intended to be used as emergency exits
820mm
700mm
1000mm
950mm
minimum area of vent shafts
1.00 sqm
3.00 sqm
0.60 sqm
0.75 sqm
minimum distance of vent shafts
800mm
600mm
450mm
100mm
minimum unobstructed area of air ducts
0.30 sqm
0.50 sqm
1.00 sqm
1.20 sqm
minimum center to center distance sprinkler heads
1.5m
1.8m
3.0m
2.4m
public land and open space which can equally enjoyed by the members of community
easement
yard
open space
setback
minimum window openings as related to floor area for rooms not provided with artificial ventilation
50%
25%
10%
30%
average car parallel parking measurement
3 x 6 meters
2.15 x 6 meters
2.5 x 5 meters
2.5 x 6 meters
average car perpendicular and diagonal parking requirement
3.0 x 6 meters
2.15 x 5 meters
2.5 x 5 meters
2.5 x 6 meters
jeepney parking requirement
3.6 x 12 meters
3.0 x 6 meters
3.6 x 18 meters
3 x 9 meters
bus / truck parking requirements
3 x 9 meters
3 x 6 meters
3.6 x 8 meters
3.6 x 12 meters
articulated truck parking requirement (10 or 12 wheeler trucks)
3.6 x 12 meters
3 x 6 meters
3.6 x 18 meters
3 x 9 meters