Font size
WorksheetsRefresher UfP Quiz
Total questions: 18
Worksheet time: 9mins
What is the unique technology of Bausch + Lomb Ultra for Presbyopia contact lens?
Advanced MoistureSeal Technology
ComfortFeel Technology
MoistureSeal Technology
ComfortMoist Technology
Ultra for Presbyopia material is called
samfilcon A
nesofilcon B
etafilcon A
lotrafilcon B
What is ULTRA for presbyopia contact lens modulus?
102
92
70
69
ULTRA for presbyopia has a base curve of ______ and lens diameter _______.
8.6mm, 14.2mm
8.5mm, 14.2mm
8.4mm, 14.0mm
8.7mm, 14.0mm
What is the function of PVP in ULTRA for presbyopia?
Keeps moisture on the surface of the lens
Keeps modulus low for incredible comfort
Makes the lens surface aspheric design
Makes lens oxygen permeability high
When a person is reading a book at near, which one of the followings will happen?
The pupil will dilate and constrict.
The pupil will constrict and dilate.
The pupil will remain constricted as long as looking at near.
The pupil will remain dilated as long as looking at near.
Ultra for Presbyopia has been approved to be used as an overnight wear lens up to 30 days without removal.
True
False
Ultra for Presbyopia power is more consistent compared to Air Optix Multifocal?
True
False
A patient with the following spectacle refraction: R: -2.50 / -0.50 x 180 ADD: +1.25 L: -4.50 ADD +1.25; Right Eye Dominant. What is the Ultra for Presbyopia initial selection for RE?
-2.25 LOW
-2.50 LOW
-2.75 LOW
-3.00 LOW
A patient wearing Ultra for Presbyopia RE: -3.75 LOW, LE: -4.00 LOW. Dominant Eye: RE. Patient complaint of Near vision blur. Which one of the followings is the best suggested correction according to the guideline?
R: -3.75 HIGH ADD
L: No Changes
R: - 4.00D HIGH ADD
L: No Changes
RE: No Changes
L: -3.75 LOW ADD
R: No Changes
L: -4.25 LOW ADD
A patient wearing Ultra for Presbyopia RE: -2.00 HIGH, LE: -3.00 HIGH. Dominant Eye: RE. Patient complaint of Near vision blur. Which one of the followings is the best suggested correction according to the guideline?
R: -1.75 HIGH ADD
L: No Changes
R: -2.25 HIGH ADD
L: No Changes
R: No Changes
L: -2.75 HIGH ADD
R: No Changes
L: -3.25 HIGH ADD
The power range of Ultra for Presbyopia is from
Plano to -10.00D
+6.00D to -10.00D
Plano to -9.00D
+6.00 to -12.00D
A patient wearing Ultra for Presbyopia RE: -3.75 LOW, LE: -4.00 LOW. Dominant Eye: RE. Patient complaint of Near vision blur and had changed the LE to -3.75 LOW. However, the patient still complains of blur vision at near. Which one of the followings will be the next step to improve the near vision?
R: -4.00 HIGH ADD
L: No Changes
R: -3.75 HIGH ADD
L: No Changes
R: No Changes
L: -4.00D HIGH ADD
R: No Changes
L: -3.75D HIGH ADD
A patient with the following spectacle refraction: R: -3.50 ADD: +2.25 L: -4.50 ADD: +2.25; Left Eye Dominant. What should be the ULTRA for Presbyopia initial lens selected?
R: -3.25 HI ADD
L: -4.50 HI ADD
R: -3.25 HI ADD
L: -4.25 HI ADD
R: -3.50 HI ADD
L: -4.25 HI ADD
R: -3.50 HI ADD
L: -4.00 HI ADD
A patient is wearing Ultra for Presbyopia R: -6.25 HI L: -6.75 HI. Dominant Eye: Right.
He told that Far vision is blurred. What should be steps for next adjustment?
R: -6.50 HI ADD
L: No changes
R: -6.00 HI ADD
L: No changes
R: No changes
L: -6.50 HI ADD
R: No changes
L: -7.00 HI ADD
What is the dk/t of Air Optix HydraGlyde Multifocal?
138
163
142
134
What is the dk/t of Biofinity Multifocal?
138
163
142
134
Which of the following is the technology used in Ultra for Presbyopia?
Aquaform technology
Smartshield technology
3-Zone Progressive
Balanced Progressive Technology
