Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical Engineering Quiz

Total questions: 20

Worksheet time: 28mins

Name
Class
Date
1.

What should be checked regarding the materials given on a material schedule before they are obtained and installed?

a)

The right type, fit for purpose, in the correct quantity

b)

The color, size, and manufacturer

c)

The warranty, brand, and price

d)

The delivery method, storage conditions, and maintenance requirements

2.

Which of the following is not a method of generating electricity using renewable energy?

a)

Solar

b)

Nuclear

c)

Wind

d)

Tidal

3.

What is one reason why AC is used in preference to DC for most electrical distribution in the UK?

a)

AC voltage can easily be stepped up and down using transformers

b)

AC is more dangerous than DC, which makes it more efficient

c)

DC can easily be converted to AC, but not vice versa

d)

AC is cheaper to produce than DC

4.

Which of the following is not a type of AC motor controller?

a)

Direct-on-line

b)

Star-delta

c)

Rotor-resistance

d)

Phase-sequencing

5.

How can the neutral current in a three-phase circuit be determined if the current for each phase is L1 = 80 A, L2 = 60 A, and L3 = 40 A?

a)

By using Ohm's Law

b)

By using a scaled triangle

c)

By measuring with an ammeter

d)

By calculating the power factor

6.

What is the purpose of a thermal cut-out in electric immersion heaters within hot water cylinders?

a)

To regulate the temperature of the water

b)

To prevent the cylinder from overheating and dangerously pressurising if the thermostat fails

c)

To increase the efficiency of the heating process

d)

To signal when the water has reached the desired temperature

7.

List three different devices that can provide overcurrent protection.

a)

Fuse, light bulb, switch

b)

Fuse, circuit breaker, thermal overload trip

c)

Resistor, capacitor, inductor

d)

Transformer, generator, relay

8.

Why might an IT earthing arrangement be selected for an installation?

a)

To ensure a stable power supply

b)

To reduce the cost of installation

c)

Where unexpected disconnection of a circuit could cause danger

d)

To simplify the design of the electrical system

9.

Why do three-phase motor circuits not usually include a neutral conductor?

a)

Because it is not necessary for the functioning of the motor

b)

Because it reduces the risk of electric shocks

c)

Because all three phases are balanced and there will be no neutral current

d)

Because it makes the motor run faster

10.

What is the correct order of the first three tests to be performed during the initial verification of a new radial final circuit in accordance with BS 7671?

a)

Insulation resistance, Continuity, Polarity

b)

Continuity, Insulation resistance, Polarity

c)

Polarity, Continuity, Insulation resistance

d)

Insulation resistance, Polarity, Continuity

11.

During an inspection of a metallic conduit system, which sense could be used to check if the conduit is securely fastened to the wall?

a)

Sense of smell

b)

Sense of sight

c)

Sense of touch

d)

Sense of hearing

12.

What is verified during the functional test of a passive infrared movement detector controlling a number of outdoor luminaires?

a)

It operates at the correct sound level

b)

It senses temperature changes in the environment

c)

It switches the correct luminaires and operates at the correct light level

d)

It changes colors depending on the movement

13.

What is the minimum insulation resistance value for SELV and PELV circuits with a nominal voltage up to and including 500 V?

a)

0.5 MΩ

b)

1.0 MΩ

c)

1.5 MΩ

d)

2.0 MΩ

14.

What is the test voltage DC for circuits with a nominal voltage above 500 V when measuring insulation resistance?

a)

250 V

b)

500 V

c)

750 V

d)

1000 V

15.

Which of the following is a GS38 requirement for an approved voltage indicator used to safely isolate a circuit prior to fault diagnosis?

a)

Fused leads

b)

Non-conductive casing

c)

Battery-operated

d)

Wireless connectivity

16.

What are two sources for safety services as given in BS 7671?

a)

Storage batteries and primary cells

b)

Generators and separate feeder

c)

Storage batteries and generators

d)

Primary cells and separate feeder

17.

What is the minimum degree of IP protection for Zone 0 in a location containing a bath?

a)

IPX4

b)

IPX7

c)

IPX1

d)

IPX0

18.

Where may surge protective devices be required within an installation?

a)

At the origin of the installation and any sub distribution boards

b)

At socket-outlets or equipment terminals

c)

At the main distribution board only

d)

Both A and B

19.

Which of the following is NOT a method of supporting an SWA cable, installed above a suspended ceiling, to comply with Regulation 521.10.202?

a)

Metallic cleats

b)

Metallic cable hangers

c)

Metal ties on tray

d)

Non-metallic cable ties

20.

Which installation reference method is mentioned for the circuit?

a)

Reference Method A

b)

Reference Method B

c)

Reference Method C

d)

Reference Method D