wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

S9.2 Rescode 55 Part 2

Total questions: 25

Worksheet time: 25mins

Name
Class
Date
1.

What is the minimum dimension clear to the sky that must be maintained for the light court next to an existing habitable room window?

a)

0.5 meters

b)

1 meter

c)

1.5 meters

d)

2 meters

2.

What is the minimum area of the light court next to an existing habitable room window?

a)

1 sqm

b)

2 sqm

c)

3 m

d)

3 sqm

3.

Can the eaves encroach on the space required for the light court to ensure daylight to an existing window?

a)

Yes, as long as light is not obstructed

b)

Yes, but only by 0.5 meters

c)

No, eaves cannot encroach on this space

d)

No, unless special permission is granted

4.

What is the angle of the arc within which a new wall must fall if it is to be within the daylight access range of an existing window?

a)

25° arc from the center of the existing window

b)

35° arc from the center of the existing window

c)

45° arc from the center of the existing window

d)

55° arc from the center of the existing window

5.

What is the 3m high wall setback from the exisiting habitable room window in the diagram, if the wall is within 55 deg arc from center of exisitng window?

a)

Half

b)

one quarter

c)

25%

d)

60%

6.

How far should a building be set back from the boundary if a north-facing habitable room window of an existing dwelling is within 3 meters of the boundary on an abutting lot and the building height is 5 meters?

a)

1.84 meters

b)

2.4 meters

c)

1 meter

d)

2 meters

7.

A north-facing window is a window with an axis perpendicular to its surface oriented?

a)

north 20 degrees east

b)

north 20 degrees west

c)

north 30 degrees east

d)

north 30 degrees west

8.

What is the minimum percentage of Public Open Space (POS) that should receive sunlight between 9 am and 3 pm on 22 September?

a)

50%

b)

75%

c)

60%

d)

80%

9.

Public Open Space (POS) should receive a minimum of how many hours of sunlight between 9 am and 3 pm on 22 September.?

a)

2 hrs

b)

3 hrs

c)

4 hrs

d)

5 hrs

10.

What is the minimum dimension that the Public Open Space (POS) must have to meet the sunlight requirement?

a)

2 meters

b)

3 meters

c)

4 meters

d)

5 meters

11.

The amount of sunlight can be further reduced for existing overshadowing greater than allowed by the standard. Is this True or False?

a)

True

b)

Fasle

12.

At what angle from the plane of the window or perimeter of the balcony, terrace, deck, or patio should views be measured to avoid overlooking issues?

a)

30° angle

b)

45° angle

c)

60° angle

d)

90° angle

13.

What is the minimum radius to be considered to prevent overlooking into existing windows according to the diagram?

a)

7.5 m radius

b)

9 m radius

c)

10 m radius

d)

12 m radius

14.

A habitable room window with a direct view into a habitable room window of an existing dwelling within a horizontal distance of 9 mts [measured at ground level] of the window, should be offset a min. of how many metres from the edge of one window to the edge of the other, as indicated in the diagram.

a)

1m

b)

1.5m

c)

2m

d)

0.5m

15.

For a window to comply with privacy standards, what is the maximum transparency allowed for fixed, obscure glazing below 1.7 mts above floor level?

a)

15%

b)

25%

c)

35%

d)

45%

16.

What characteristics should screens used to obscure a view have?

a)

A) Perforated panels or trellis with no more than 25% openings or solid translucent panels

b)

B) Temporary and removable screens

c)

C) Screens that are not designed to blend in with the development

d)

D) Screens with more than 50% openings

17.

What is the minimum area required for an outdoor space clear to the sky or a light court for a window in a habitable room to face?

a)

1 square metre

b)

2 square metres

c)

3 square metres

d)

4 square metres

18.

For a window in a habitable room to face a verandah, how much of the verandah's perimeter must be open?

a)

At least one fourth of its perimeter

b)

At least one third of its perimeter

c)

At least half of its perimeter

d)

The entire perimeter

19.

For a window in a habitable room to face a carport, if the sides are opened one-third of its' perimeter, how many sides must the carport be opened?

a)

Zero open side

b)

One open side

c)

Two open sides

d)

More than two open sides

20.

What is the minimum width required for a balcony to qualify as private open space under Standard B28?

a)

3 m

b)

2 m

c)

1.6 m

d)

10 m²

21.

What is the minimum dimension required for the secluded private open space as part of the total private open space for a dwelling, according to the information provided?

a)

40 m²

b)

25 m²

c)

3 m

d)

1.6 m

22.

In the diagram, an area of 40 m², with one part of the private open space to consist of secluded Private Open Space [POS] at the side or rear of the dwelling or residential building with a minimum area. What is the min. area of the secluded POS?

a)

40 m²

b)

25 m²

c)

3 m

d)

1.6 m

23.

Standard B28: If a Balcony of 8 m² is provided with a minimum width is 1.6m, what other provision must the balcony satisfy for this standard?

a)

Access from a kitchen

b)

Access from an habitable room

c)

Access from a living room

d)

Access from a POS

24.

Standard B28: If a Roof-top area of 10 m² is provided what is the minimum width of the roof-top area and what other provision must the roof-top area satisfy?

a)

2m

b)

Access from a living room

c)

Access from an habitable room

d)

1.6 m

25.

According to the image, what does a front fence include?

a)

Any fence within 1.5 meters of the street

b)

Any fence within 3 meters of the street

c)

Any fence within 5 meters of the street

d)

Any fence regardless of its distance from the street