T28CT Ceiling & Internal Finsihes Quiz

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

What is a ceiling?

a)

It is not a structural element

b)

It is an overhead interior surface that covers the upper limits of a room

c)

It is a finished surface concealing the underside of the roof structure or the floor of a story above

d)

It is a type of flooring

2.

Which of the following is NOT a type of ceiling?

a)

Direct Fixed Ceiling

b)

Suspended Ceiling

c)

Retractable Ceiling

d)

Floating Ceiling

3.

What is the purpose of direct fixing clips in a direct fixed ceiling?

a)

To support the weight of the ceiling

b)

To fix along the sections in accordance with the relevant maximum span tables

c)

To provide insulation

d)

To enhance the aesthetic appearance

4.

How should each Furring Channel be spaced in a direct fixed ceiling?

a)

According to the builder's preference

b)

As per the manufacturers' recommendations

c)

At random intervals

d)

Based on the room size

5.

How is the ceiling supported in a suspended ceiling system?

a)

By using heavy steel beams

b)

By using a lightweight hanging frame (grid system 1200mm x 1200mm)

c)

By attaching directly to the roof

d)

By using wooden planks

6.

What is the thickness of the plasterboard used in the ceiling direct fixed details?

a)

10mm

b)

13mm

c)

15mm

d)

20mm

7.

At what spacing are the mild steel strap hangers placed in the ceiling direct fixed details?

a)

1000mm

b)

1200mm

c)

1500mm

d)

1800mm

8.

What is the maximum distance allowed between hanging wires in the given ceiling design?

a)

101 mm

b)

203 mm

c)

12 mm

d)

50 mm

9.

According to the general note, what must the ceiling area with control joint follow?

a)

Vertical bracing requirements

b)

Lateral bracing requirements

c)

Diagonal bracing requirements

d)

No specific requirements

10.

What is the required concrete stress grade at 28 days?

a)

15MPa

b)

20MPa

c)

25MPa

d)

30MPa

11.

What standard should all timber framing comply with?

a)

A.S.1428.1

b)

A.S.1668

c)

A.S.1684

d)

A.S.3660

12.

What should all disabled works comply with?

a)

A.S.1428.1

b)

A.S.1668

c)

A.S.1684

d)

A.S.3660

13.

What standard should mechanical ventilation comply with?

a)

A.S.1428.1

b)

A.S.1668

c)

A.S.1684

d)

A.S.3660

14.

What specification must all materials comply with for early fire hazard indices?

a)

SPEC C1.1 10 of the BCA

b)

SPEC A2.3 15 of the BCA

c)

SPEC B4.2 20 of the BCA

d)

SPEC D3.5 25 of the BCA

15.

What type of mesh should be provided throughout the roof area in accordance with the Occupational Health and Safety Act?

a)

AUSMESH 300

b)

AUSMESH 200

c)

AUSMESH 100

d)

AUSMESH 400