1.

What is the correct ratio of gas and oxygen required for complete combustion

a)

C4 + O2

b)

CH4 + CO2

c)

CH4 + 2O2

d)

CH4 + O2

2.

What three components are required to create fire

a)

Oxygen + Fuel + Ignition

b)

Carbon Dioxide + Fuel + Ignition

c)

Carbon Monoxide + Fuel + Ignition

d)

Nitrogen + Fuel + Ignition

3.

what is the correct ratio for complete combustion when CH4 + 2O2 =

a)

CO + H2S

b)

CH4 + CO2

c)

CO2 + 2H2O

d)

H2S + 2H2O

4.

What is a sign of complete combustion of natural gas

a)

very tight yellow flame

b)

very tight blue flame

c)

vey floppy yellow flame

d)

Very floppy blue flame

5.

Open Flue chimney system operates on what principle

a)

cold air which is more dense than hot air will rises and travel up the flue

b)

hot air which is more dense than cold air will rises and travel up the flue

c)

cold air which is less dense than hot air will rises and travel up the flue

d)

hot air which is less dense than cold air will rises and travel up the flue

6.

what is the definition of a down draught diverter

a)

 form of draught break intended to prevent conditions in the main length of flue from interfering with the combustion performance of an open-flued appliance. It allows the appliance to operate without interference from adverse wind conditions and excessive draught.

b)

factory-made counter-balanced flap device admitting air to the flue, from the same space as the combustion air, to prevent excessive variations in the draught. It is usual for these to be in the fluepipe or chimney, but they may be located on the appliance.

7.

what is the definition of a draught stabiliser

a)

is a form of draught break intended to prevent conditions in the main length of flue from interfering with the combustion performance of an open-flued appliance. It allows the appliance to operate without interference from down-draughts that may occur in adverse wind conditions and excessive draught.

b)

is a factory-made counter-balanced flap device admitting air to the flue, from the same space as the combustion air, to prevent excessive variations in the draught. It is usual for these to be in the fluepipe or chimney, but they may be located on the appliance.

8.

what is the height of a flue chimney system next to an adjacent structure

a)

600mm

b)

1200mm

c)

900mm

d)

300mm

9.

what test is used to check flue integrity

a)

flue flow

b)

spillage

10.

what test is used to confirm safe operation of an open flue boiler flue system when it is switched on

a)

flue flow

b)

spillage

11.

what is the fuse rating of a 11kw electric shower

a)

3A

b)

10A

c)

32A

d)

45A

12.

when using electrical tools on-site where the conditions are potentially damp what voltage of tool would be correct

a)

230v ac RCD protected

b)

110 cv reduced voltage supply

13.

wind generation needs to comply with what regulations

a)

building regulations

b)

british standards

c)

gas industry standards

d)

town & country planning regulations

14.

Solar photovoltaic (PV) is used for

a)

generating electricity

b)

generating hot water

15.

is LPG heavier than air

a)

Yes, it sinks and must not be stored near drains

b)

No, it floats and can be stored near drains