wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Water Regulations Quiz

Total questions: 55

Worksheet time: 28mins

Name
Class
Date
1.

Which of the following is a type of water regulation mentioned in the document?

a)

The Water Regulations (1999)

b)

The Water Regulations (2005)

c)

The Water Regulations (2010)

d)

The Water Regulations (2015)

2.

What does WRAS stand for?

a)

Water Regulation Advisory Scheme

b)

Water Regulation Approval System

c)

Water Regulation and Safety

d)

Water Regulation and Sanitation

3.

Which part of the Building Regulations is mentioned in the document?

a)

Part A

b)

Part B

c)

Part G

d)

Part H

4.

What is the purpose of the Directory of fittings mentioned in the document?

a)

To list WRAS approved fittings

b)

To list water safety guidelines

c)

To list building regulations

d)

To list sanitation standards

5.

What does BS6700 cover?

a)

Workmanship on building sites

b)

Design, installation, testing, and maintenance

c)

Code of practice for hot and cold water services

d)

Electrical installations

6.

What is the focus of BS8000 pt15?

a)

Design, installation, testing, and maintenance

b)

Electrical installations

c)

Workmanship on building sites

d)

Fire safety regulations

7.

What does BS8000 pt15 specifically address?

a)

Electrical installations

b)

Fire safety regulations

c)

Code of practice for hot and cold water services

d)

Design, installation, testing, and maintenance

8.

What information do manufacturers' instructions typically include?

a)

Installation requirements, maintenance and servicing requirements, fault diagnosis, and spare parts

b)

Marketing strategies and sales targets

c)

Employee training programs and schedules

d)

Customer feedback and reviews

9.

What additional details do manufacturers' instructions provide?

a)

Flow rates and maximum temperatures for appliances

b)

Warranty periods and return policies

c)

Customer service contact information

d)

Product color options and design features

10.

What are the two main categories of hot water supply systems?

a)

Centralised system and Localised system

b)

Instantaneous system and Storage system

c)

Thermal store and Gas-fired

d)

Direct and Indirect

11.

Which type of system includes a "Combi boiler or instantaneous water heater"?

a)

Localised system

b)

Centralised system

c)

Storage system

d)

Gas-fired system

12.

In a centralised system, what are the two types of storage systems?

a)

Gas-fired and Electric

b)

Thermal store and Gas storage water heater

c)

Open-vented/cistern-fed system and Unvented/mains-fed system

d)

Combination vented 'fortic' systems and Immersion heater

13.

Which type of system is described as "Instantaneous" in a localised or single-point system?

a)

Gas-fired

b)

Electric

c)

Thermal store

d)

Combination vented 'fortic' systems

14.

What type of heater is included in both centralised and localised storage systems?

a)

Gas-fired

b)

Immersion heater

c)

Thermal store

d)

Combi boiler

15.

Which type of system involves water being heated to a specific temperature for domestic use?

a)

Centralised

b)

Localised

c)

Hot water

d)

Instantaneous

16.

In which type of system is water heated and/or stored centrally in the building and distributed to all hot water outlets?

a)

Localised

b)

Centralised

c)

Stored

d)

Instantaneous

17.

What is the characteristic of a localised water heating system?

a)

Water is heated on demand when hot water outlets are opened.

b)

Water is heated and/or stored locally to one specific draw-off point area.

c)

A cylinder of water is heated to temperature before being distributed.

d)

Water is heated to a specific temperature for domestic use.

18.

Which type of system uses a cylinder of water heated to temperature before being distributed to hot water outlets?

a)

Instantaneous

b)

Centralised

c)

Stored

d)

Localised

19.

In which type of system is water heated on demand when hot water outlets are opened?

a)

Stored

b)

Instantaneous

c)

Centralised

d)

Localised

20.

Which type of centralised hot water system is commonly used in a domestic property and uses a hot water cylinder, centrally located in an airing cupboard?

a)

Centralised – stored hot water

b)

Centralised – instantaneous hot water

c)

Decentralised – stored hot water

d)

Decentralised – instantaneous hot water

21.

Which type of centralised hot water system is commonly used in smaller domestic properties and uses a combination boiler?

a)

Centralised – stored hot water

b)

Centralised – instantaneous hot water

c)

Decentralised – stored hot water

d)

Decentralised – instantaneous hot water

22.

What does a centralised – stored hot water system use to heat the water?

a)

Combination boiler

b)

Solar panels

c)

Boiler (or immersion)

d)

Electric heater

23.

How does a centralised – instantaneous hot water system heat water?

a)

By using a hot water cylinder

b)

By using a combination boiler

c)

By using solar panels

d)

By using an electric heater

24.

What type of system is described in the image?

a)

Centralised open vented indirect gravity system

b)

Centralised closed vented direct gravity system

c)

Decentralised open vented indirect gravity system

d)

Decentralised closed vented direct gravity system

25.

Where is the centralised open vented indirect gravity system commonly found?

a)

New properties

b)

Older properties

c)

Commercial buildings

d)

Industrial plants

26.

What does the primary flow and return from the boiler rely on to transfer heat from the boiler to the cylinder?

a)

Radiation

b)

Convection

c)

Conduction

d)

Evaporation

27.

What type of system is commonly installed today for heating?

a)

Centralised open vented indirect pumped primaries

b)

Decentralised closed vented direct pumped primaries

c)

Centralised closed vented direct pumped primaries

d)

Decentralised open vented indirect pumped primaries

28.

How is heat transferred from the boiler to the cylinder in a centralised open vented indirect pumped primary system?

a)

By natural convection

b)

By the use of a pump or circulator through the coil

c)

By direct contact

d)

By radiation

29.

What does the F&E feed in a heating system?

a)

The secondary circuit – hot water distribution

b)

The primary circuit – boiler, cylinder, and F&E

c)

The central heating system

d)

The electrical circuit

30.

What does the CWSC feed in a heating system?

a)

The primary circuit – boiler, cylinder, and F&E

b)

The electrical circuit

c)

The secondary circuit – hot water distribution

d)

The central heating system

31.

What is a characteristic of a direct hot water cylinder system using a boiler?

a)

It uses a heat exchanger coil in the cylinder.

b)

The boiler heats the water that directly comes out of the draw off points.

c)

It does not require a boiler.

d)

The water is heated by solar panels.

32.

In a direct hot water cylinder system using a boiler, what component is absent in the cylinder?

a)

Heat exchanger coil

b)

Boiler

c)

Draw off points

d)

Vent pipe

33.

What type of system uses electric immersion heaters and does not have a heat exchanger coil?

a)

Indirect hot water cylinder system

b)

Direct hot water cylinder system

c)

Solar water heating system

d)

Gas boiler system

34.

How many immersion heaters are used in the direct hot water cylinder system described?

a)

One

b)

Two

c)

Three

d)

Four

35.

What do the immersion heaters in the direct hot water cylinder system heat?

a)

The water in the heat exchanger coil

b)

The air in the room

c)

The water that directly comes out of the draw-off points

d)

The water in the secondary hot water system

36.

What type of pressure do open vented systems rely on?

a)

High pressure

b)

Low pressure

c)

Medium pressure

d)

Variable pressure

37.

What is the primary function of the vent in an open vented system?

a)

To increase water temperature

b)

To act as a safety relief

c)

To reduce water flow

d)

To filter impurities

38.

Where does the vent pipe from the hot water cylinder terminate in an open vented system?

a)

Over the cold water storage cistern

b)

Under the hot water cylinder

c)

Inside the heating system

d)

Outside the building

39.

What does the vent allow when the system is filled?

a)

Water to flow out

b)

Air to flow out

c)

Heat to escape

d)

Pressure to build up

40.

What are the two main issues the vent helps to manage in an open vented system?

a)

Water contamination and pressure build-up

b)

Expansion and contraction heating and cooling, and overheating on control failure

c)

Water flow and temperature regulation

d)

Noise reduction and energy efficiency

41.

What does BS6700 recommend regarding the capacity of the CWSC feeding a hot water cylinder?

a)

The capacity should be half the capacity of the cylinder.

b)

The capacity should be twice the capacity of the cylinder.

c)

The capacity should be at least the capacity of the cylinder.

d)

The capacity should be less than the capacity of the cylinder.

42.

What is the minimum size of the CWSC if it feeds both hot and cold water?

a)

115 litres

b)

200 litres

c)

230 litres

d)

300 litres

43.

What is the minimum size of the CWSC if it feeds just the hot system?

a)

100 litres

b)

115 litres

c)

150 litres

d)

200 litres

44.

What is the minimum size of the vent pipe?

a)

15mm

b)

22mm

c)

30mm

d)

45mm

45.

Which of the following is not allowed on the vent pipe?

a)

Valve

b)

Elbow joint

c)

T-joint

d)

Coupling

46.

How long should the hot water distribution pipe be before the vent pipe connection?

a)

300mm

b)

450mm

c)

600mm

d)

750mm

47.

According to which standard should the cold feed be sized?

a)

BS6700

b)

BS8000

c)

BS5000

d)

BS9000

48.

What does CWSC need to be for head pressure?

a)

As low as possible

b)

As high as possible

c)

At the same level as the cylinder

d)

Below the cylinder

49.

Where does the cold feed pipe go and what does it have at the lowest point?

a)

To the radiator and has a valve

b)

To the cylinder and has a DOV

c)

To the boiler and has a filter

d)

To the tap and has a regulator

50.

According to BS6700, what should be done if valves are found on the route of the vent pipe?

a)

They should be left as they are.

b)

They should be replaced with new valves.

c)

They should be removed.

d)

They should be painted.

51.

In a direct system, how is the hot water cylinder heated in more modern systems?

a)

By a heat exchanger

b)

By a coil

c)

By immersion heaters

d)

By solar panels

52.

What is absent in a direct system's hot water cylinder?

a)

Immersion heaters

b)

Heat exchanger or coil

c)

Boiler

d)

Cold water feed

53.

In older direct systems, how was the water heated?

a)

By immersion heaters

b)

By a heat exchanger

c)

By the boiler

d)

By solar panels

54.

In an indirect open vented system, what component acts as the heat exchanger to heat the stored water?

a)

External coil

b)

Internal coil

c)

Immersion heater

d)

Primary flow connection

55.

What is a common feature of cylinders in an indirect open vented system?

a)

They have a primary flow connection.

b)

They have an external coil.

c)

They normally have a back-up immersion.

d)

They have a cold feed connection.