1.

Before conducting a soundness test, what should you always do?

a)

Check the water pressure

b)

Walk around the system to make sure all joints have been made

c)

Measure the temperature

d)

Inspect the electrical wiring

2.

Which of the following is NOT part of the visual check before soundness testing?

a)

Open ends

b)

Soldered joints made

c)

Compression joints tight

d)

Measure the pipe length

3.

What is the purpose of the soundness test mentioned in the document?

a)

To check the electrical connections

b)

To ensure the system is visually appealing

c)

To verify the integrity of the joints and connections

d)

To measure the system's efficiency

4.

What types of pipes require different soundness tests according to the document?

a)

Copper and plastic pipes

b)

Steel and aluminum pipes

c)

Rigid pipe (copper and steel) and plastic pipe

d)

Flexible and rigid pipes

5.

What is the first step in the testing and decommissioning process?

a)

Set up equipment

b)

Visual inspection

c)

Test period

d)

Final check

6.

Which step comes immediately after setting up the equipment in the testing and decommissioning process?

a)

Visual inspection

b)

Final check

c)

Test period

d)

Complete documentation

7.

What is the final step in the testing and decommissioning process?

a)

Final check

b)

Test period

c)

Complete documentation

d)

Visual inspection

8.

What is the first step in the soundness testing of rigid pipes (copper and steel)?

a)

Walk around the system and check for leaks

b)

Slowly fill the system with water

c)

Attach the hydraulic test bucket

d)

Pump system up to 1.5 times the working pressure

9.

How long should the system be left to stand for temperature stabilisation during soundness testing?

a)

15 minutes

b)

30 minutes

c)

45 minutes

d)

60 minutes

10.

What should be done if a pressure drop is detected during soundness testing?

a)

Increase the pressure

b)

Walk around the system again

c)

Rectify and re-test

d)

Leave the system for another hour

11.

To what pressure should the system be pumped during soundness testing if the working pressure is 3 bar?

a)

3 bar

b)

4 bar

c)

4.5 bar

d)

5 bar

12.

What is the purpose of attaching the hydraulic test bucket during soundness testing?

a)

To fill the system with water

b)

To check for leaks

c)

To measure the pressure

d)

To stabilise the temperature

13.

What is the first step in Test A for soundness testing of a plastic pipe (polybutylene)?

a)

Walk around the system and check for leaks

b)

Pump system to 1 bar

c)

Slowly fill the system with water

d)

Increase pressure to 1.5 times working pressure

14.

How long should you wait after pumping the system to 1 bar to check for loss of pressure?

a)

15 minutes

b)

30 minutes

c)

45 minutes

d)

60 minutes

15.

To what pressure should the system be increased for 15 minutes during Test A?

a)

1 bar

b)

1.5 times working pressure

c)

2 times working pressure

d)

0.5 times working pressure

16.

What should be done after reducing the pressure to one-third for a further 45 minutes?

a)

Walk around the system and check for leaks

b)

Increase pressure to 1.5 times working pressure

c)

Check for pressure loss

d)

Slowly fill the system with water

17.

What is the main reason for not wanting to damage the plastic pipe or O rings during Test A?

a)

To save time

b)

To ensure the system is sound

c)

To reduce costs

d)

To avoid water wastage

18.

What is the first step in Test B for soundness testing of a plastic pipe (polybutylene)?

a)

Walk around system and check for leaks

b)

Pump system to manufacturer’s test pressure

c)

Slowly fill the system with water

d)

Inspect the pressure loss after 30 minutes

19.

How long should you leave the system after inspecting the pressure loss for the first time in Test B?

a)

30 minutes

b)

60 minutes

c)

90 minutes

d)

120 minutes

20.

What should you do if the total pressure loss is less than 0.2 bar in Test B?

a)

Refill the system with water

b)

Soundness is good

c)

Check for leaks again

d)

Increase the test pressure

21.

Why is it important not to damage the plastic pipe or O rings during Test B?

a)

To ensure the system is properly filled with water

b)

To prevent leaks

c)

To maintain the manufacturer's test pressure

d)

To avoid pressure loss

22.

What is the first step in the flushing and disinfecting process after a new system or section of pipework has been installed?

a)

Re-fill the system

b)

Open the kitchen tap and allow water to run until clear of debris/colour

c)

The system is re-filled with water and then drained down from the lowest point

d)

Add disinfectant to system (sodium hypochlorite solution or chlorine) for 1 hour

23.

What should be done after re-filling the system during the flushing and disinfecting process?

a)

Add disinfectant to system (sodium hypochlorite solution or chlorine) for 1 hour

b)

Open the kitchen tap and allow water to run until clear of debris/colour

c)

Drain the system from the lowest point

d)

Do likewise with all other outlets in the property

24.

How long should disinfectant be added to the system during the flushing and disinfecting process?

a)

30 minutes

b)

2 hours

c)

1 hour

d)

15 minutes

25.

Which disinfectant is mentioned for use in the flushing and disinfecting process?

a)

Sodium hypochlorite solution or chlorine

b)

Hydrogen peroxide

c)

Ammonia

d)

Bleach

26.

What is the first step in the flushing and disinfecting process according to the provided material?

a)

Drain system

b)

Test chlorine levels at each outlet

c)

Flush system through from each outlet until no chlorine is present

d)

Add chlorine to the system

27.

According to the provided material, what standard should be followed when testing chlorine levels at each outlet?

a)

BS6700

b)

ISO9001

c)

ASTM D512

d)

EPA 815-R-99-010

28.

What should be done after draining the system in the flushing and disinfecting process?

a)

Add more chlorine

b)

Test chlorine levels again

c)

Flush system through from each outlet until no chlorine is present

d)

Close all outlets

29.

What tool is used to check the flow rate according to the provided learning material?

a)

Pressure gauge

b)

Wier cup

c)

Thermometer

d)

Hydrometer

30.

According to the learning material, how should dirt and debris be flushed through?

a)

Using a pressure gauge

b)

As per BS6700

c)

With a wier cup

d)

By opening all draw-off points

31.

What should be done to check the pressure according to the learning material?

a)

Use a wier cup

b)

Flush through as per BS6700

c)

Use a pressure gauge

d)

Open all draw-off points

32.

What is the procedure for checking draw-off points as per the learning material?

a)

Use a wier cup

b)

Flush through as per BS6700

c)

Use a pressure gauge

d)

Open all draw-off points, making sure they open and shut off

33.

What should be done to all valves during testing and decommissioning?

a)

Ensure correct temperature is set and recorded

b)

Open and close all valves to ensure operation and label all valves

c)

Ensure correct temperature setting and inform customer

d)

Ensure correct temperature at draw-off points

34.

What is the purpose of checking blending valves?

a)

Ensure correct temperature setting and inform customer

b)

Open and close all valves to ensure operation and label all valves

c)

Ensure correct temperature is set and recorded

d)

Ensure correct temperature at draw-off points

35.

What should be ensured about thermostats during testing and decommissioning?

a)

Ensure correct temperature is set and recorded

b)

Open and close all valves to ensure operation and label all valves

c)

Ensure correct temperature setting and inform customer

d)

Ensure correct temperature at draw-off points

36.

What should be checked regarding temperatures during testing and decommissioning?

a)

Ensure correct temperature is set and recorded

b)

Open and close all valves to ensure operation and label all valves

c)

Ensure correct temperature setting and inform customer

d)

Ensure correct temperature at draw-off points

37.

What should be done after the system has been proved?

a)

Disassemble the system

b)

Complete the documentation and hand over to the customer

c)

Ignore the system

d)

Reinstall the system

38.

What should be shown to the customer during the handover of the system?

a)

Only the settings

b)

Only the valves

c)

All the settings and valves

d)

None of the settings and valves

39.

Which of the following is NOT mentioned as part of the documentation to be handed over to the customer?

a)

Manufacturer’s instructions

b)

Benchmark certificate

c)

Warranty

d)

Installation guide

40.

Which of the following is the first step in decommissioning a hot water system for maintenance and replacement of components?

a)

Components identified

b)

Heat source safely isolated

c)

Customer informed

d)

Fuses removed

41.

What should be done to the heat source during the decommissioning of a hot water system?

a)

Components identified

b)

Heat source safely isolated

c)

System drained to safe location

d)

Open ends capped

42.

Which of the following actions ensures safety by preventing electrical hazards during decommissioning?

a)

Warning notice placed on heat source

b)

Fuses removed

c)

System drained to safe location

d)

No dead legs left

43.

What should be done to the open ends of the system during decommissioning?

a)

Components identified

b)

Heat source safely isolated

c)

Open ends capped

d)

No dead legs left

44.

Why is it important to place a warning notice on the heat source during decommissioning?

a)

To inform the customer

b)

To identify components

c)

To ensure the heat source is safely isolated

d)

To prevent unauthorized access and ensure safety

45.

What is the first step when a system is temporarily decommissioned for a component replacement?

a)

The system is refilled and tested

b)

The part is replaced

c)

The customer will have to be informed

d)

A hose pipe is connected to a suitable drain point

46.

What must be done to the system before it is labeled during decommissioning?

a)

The system is refilled and tested

b)

The part is replaced

c)

The customer will have to be informed

d)

The system will be safely isolated

47.

Where is the hose pipe connected during the decommissioning process?

a)

To a suitable drain point

b)

To the main water supply

c)

To the electrical outlet

d)

To the air vent

48.

What happens after the part is replaced in the decommissioning process?

a)

The system is safely isolated

b)

The system is refilled and tested

c)

The customer is informed

d)

The hose pipe is connected

49.

Which of the following items may need periodic maintenance or replacement, leading to temporary system decommissioning?

a)

Hot water cylinder

b)

Electrical wiring

c)

Insulation material

d)

Paint

50.

Which item listed below is NOT mentioned as needing periodic maintenance or replacement?

a)

Boiler

b)

Shower

c)

Valves

d)

Electrical wiring

51.

What is one of the common items that may need periodic maintenance or replacement, causing the system to be temporarily decommissioned?

a)

Cold water storage cistern

b)

Electrical outlets

c)

Light bulbs

d)

Flooring

52.

Which of the following is included in the list of items that may need periodic maintenance or replacement?

a)

Terminal fitting

b)

Wall paint

c)

Carpet

d)

Windows

53.

What is one of the conditions under which a system is permanently decommissioned?

a)

When a new system is installed alongside the old system

b)

When the old system is stripped out and replaced by an updated system

c)

When the system is temporarily shut down for maintenance

d)

When the system is upgraded without removing the old system

54.

What must be done to the system before it is permanently decommissioned?

a)

The system must be painted

b)

The system must be safely isolated and labeled

c)

The system must be expanded

d)

The system must be upgraded

55.

What is connected to a suitable drain point during the decommissioning process?

a)

A water pump

b)

A hose pipe

c)

An electrical wire

d)

A gas pipe

56.

Who needs to be informed when a system is permanently decommissioned?