wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

ICIT: SEQUENCE OF CONTROL+DIRECT AND INDIRECT CONTACT

Total questions: 25

Worksheet time: 13mins

Name
Class
Date
1.

What is the purpose of the kWh (Energy) meter in the AC incoming supply system?

a)

To provide overcurrent protection

b)

To distribute energy to final circuits

c)

To register energy consumption

d)

To isolate and switch the circuit

2.

What are the two forms of electric shock mentioned in SS638: 2018?

a)

Direct and Indirect

b)

Primary and Secondary

c)

Visible and Invisible

d)

Internal and External

3.

What is the purpose of earthed equipotential bonding and automatic disconnection of supply?

a)

Protection against short circuit

b)

Protection against overcurrent

c)

Protection against indirect contact

d)

Protection against direct contact

4.

What is the main characteristic of Class II equipment?

a)

Use of supplementary insulation for safety

b)

Presence of live parts in the equipment

c)

Reliance on basic insulation for protection against electric shock

d)

Connection of exposed metal work to a protective conductor

5.

What is the definition of overload current?

a)

Result of two or more live conductors touching together

b)

Result of a phase conductor touching the protective conductor

c)

Result of adding more loads than the designed condition

d)

Result of a current passing through the body of a person

6.

What is the term used to signify the possible value of short-circuit current at the point where the protective device is installed?

a)

Prospective short-circuit current

b)

Fault current

c)

Residual current

d)

Overload current

7.

Where should fuses and single-pole circuit breakers be installed in systems with earthed neutrals?

a)

In the neutral conductor

b)

In the phase conductors

c)

In the protective conductor

d)

In the earth conductor

8.

What happens if the neutral is fused in a circuit during an overload or short-circuit?

a)

The circuit will operate normally

b)

The live fuse will blow

c)

The circuit becomes safe

d)

The circuit becomes dangerous

9.

What is the purpose of bonding all extraneous conductive parts in an electrical system?

a)

To reduce the insulation resistance

b)

To prevent the flow of current

c)

To create an equipotential zone

d)

To increase the risk of electric shock

10.

What is the most common method of protection against indirect shock?

a)

Use of Class IV equipment

b)

Use of Class III equipment

c)

Use of Class II equipment

d)

Use of Class I equipment

11.

What is the result of two or more live conductors touching together?

a)

Shock current

b)

Earth fault

c)

Short circuit

d)

Overload current

12.

What is the definition of shock current?

a)

Current passing through the body of a person

b)

Result of adding more loads than the designed condition

c)

Result of two or more live conductors touching together

d)

Result of a phase conductor touching the protective conductor

13.

What is the purpose of the main switch or main circuit breaker in an AC incoming supply system?

a)

To provide overcurrent protection

b)

To register energy consumption

c)

To isolate and switch the circuit

d)

To distribute energy to final circuits

14.

What is the function of the distribution board in an electrical system?

a)

To isolate and switch the circuit

b)

To register energy consumption

c)

To distribute energy to final circuits

d)

To provide overcurrent protection

15.

What safety measures can be taken to avoid electric shock?

a)

Ignoring safety protocols

b)

Using insulated tools

c)

Working in wet conditions

d)

Wearing rubber gloves

16.

What is the purpose of the RCD (Residual Current Device) in an electrical system?

a)

To provide overcurrent protection

b)

To register energy consumption

c)

To detect and disconnect faulty circuits

d)

To distribute energy to final circuits

17.

What is the main function of an MCB (Miniature Circuit Breaker) in a circuit?

a)

To isolate and switch the circuit

b)

To measure energy consumption

c)

To provide overvoltage protection

d)

To distribute energy to final circuits

18.

What is the significance of the earth connection in an electrical installation?

a)

To increase the risk of electric shock

b)

To provide a return path for fault currents

c)

To reduce the insulation resistance

d)

To prevent the flow of current

19.

What is the primary function of a residual current device (RCD) in an electrical system?

a)

To provide overcurrent protection

b)

To measure energy consumption

c)

To detect and disconnect faulty circuits

d)

To distribute energy to final circuits

20.

What is the purpose of equipotential bonding in an electrical installation?

a)

To increase the risk of electric shock

b)

To provide a return path for fault currents

c)

To reduce the insulation resistance

d)

To prevent the flow of current

21.

What is the definition of short circuit in an electrical circuit?

a)

Result of two or more live conductors touching together

b)

Result of adding more loads than the designed condition

c)

Result of a current passing through the body of a person

d)

Result of a phase conductor touching the protective conductor

22.

What is the primary purpose of a fuse in an electrical circuit?

a)

To provide overcurrent protection

b)

To regulate voltage levels

c)

To connect different circuits

d)

To store electrical energy

23.

What is the purpose of using a surge protector in an electrical system?

a)

To prevent overcurrent

b)

To protect against voltage spikes

c)

To measure energy consumption

d)

To isolate and switch the circuit

24.

What is the role of a circuit breaker in an electrical installation?

a)

To provide a connection between circuits

b)

To interrupt the flow of current during a fault

c)

To measure voltage levels

d)

To increase the current capacity of the circuit

25.

What is the function of a transformer in an electrical system?

a)

To convert AC to DC

b)

To step up or step down voltage levels

c)

To store electrical energy

d)

To provide overcurrent protection