WorksheetsUnsafe Situations (Examples) GIUSP
Total questions: 12
Worksheet time: 6mins
3.3 In an emergency situation (e.g. gas escaping) where there is restricted access or there is not a handle fitted to ECV (AR)
3.10 Pipework suitable for gas used in an inappropriate location and/or situation (AR)
3.11 Pipework showing significant signs of damage from corrosion or mechanical damage (AR)
3.12 Gas pipework located within a cavity wall or void but not within a purpose made duct (AR)
8.8 Unsupported flue system (AR)
8.8 Unsupported flue system (AR) & 6.2 Leakage of products of combustion (ID)
6.5 No means of examining a room sealed concealed flue system (AR)
6.5 No means of examining a room sealed concealed flue system (AR) & 6.2 Leakage of products of combustion (ID)
1.4 Flueless appliances: evidence of poor combustion occurring (ID)
6.2 Leakage of products of combustion from room sealed chimney system (ID)
Flueless appliance with visual signs of incomplete combustion (ID)
1.4 Flueless appliances: evidence of poor combustion occurring (ID) & Flueless appliance with visual signs of incomplete combustion (ID)
3.1 Pipework with an open end connected to a gas supply (ID)
3.2 Pipework and/or fittings of inappropriate material for purpose (ID) also RIDDOR reportable
3.6 Undersized pipework proved to be affecting the safe operation if any appliance (ID)
3.10 Pipework suitable for gas used in inappropriate location and/or situation (AR)
2.4 Medium pressure or higher pressure fed regulator relief valve and/or vent pipe discharging in an unsafe location (ID)
2.5 Meter and/or regulator showing significant signs of damage (AR)
2.8 Pathway for gas to enter property from meter box (AR)
3.5 In an non-emergency situation where there is restricted access or there is not a handle fitted to ECV
3.10 Pipework suitable for gas used in an inappropriate location and/or situation (AR)
3.11 pipework showing significant signs of damage from corrosion or mechanical damage (AR)
3.13 Gas pipework located within a cavity wall or void not within a purpose provided duct (AR)
3.4 Undersized pipework proved to be affecting the safe operation of any appliance (ID)
Why was the gas supply re-routed? Is this installation acceptable?
Yes, since the old supply is capped off and meter box knock out sealed this installation now complies with GSIUR and GIUSP
No, although the gas supply has been re-routed the PEB still enters the property (in accordance with 2.10 (AR))
The rear of the meter box is still compromised (AR)
3.2 Pipework and/or fittings of inappropriate material for purpose ID & RIDDOR reportable
3.2 Pipework and/or fittings of inappropriate material for purpose ID & RIDDOR reportable
3.4 Undersized pipework proved to be affecting the safe operation of any appliance
3.2 Pipework and/or fittings of inappropriate material for purpose ID & RIDDOR reportable & 2.2 Incorrect gas pressure at the outlet of the primary meter installation that affects safe operation of any appliance & 3.2 Pipework and/or fittings of inappropriate material for purpose ID & RIDDOR reportable
7.2 Missing air intake cap (AR)
7.2 Missing gas sample point (ID)
7.2 Grommets forming part of the combustion circuit missing/damaged (no evidence of leakage of products of combustion) (AR)
7.2 Air inlet sample point missing (AR)
7.2 Flue gas analysis sample point missing/damaged regardless of evidence of products of combustion) (ID)
7.2 Grommets forming part of the combustion circuit missing/damaged (no evidence of leakage of products of combustion)
non-emergency situation
3.3 In an emergency situation where there is restricted access or not a handle fitted to the ECV (ID)
3.5 In an non-emergency situation where there is restricted access or not a handle fitted to the ECV (AR)
3.6 No AECV at point of entry to property where one is required and where there is not a handle fitted to the ECV (AR)
3.2 Pipework and/or fittings of inappropriate material for purpose (ID)
7.3 Appliance not suitable for use with the gas supplied (ID)
7.11 Flexible gas connection to a flued domestic appliances (AR)
3.10 Pipework suitable for gas used in an inappropriate location and/or situation (AR)