PLC Analog Signals 1 and 2 unit

Total questions: 45

Worksheet time: 23mins

Name
Class
Date
1.

PLC works with which values?

a)

Octal

b)

Boolean

c)

Hexadecimal

2.

1 nibble =

a)

4 byte

b)

4 bits

c)

4 KB

3.

1 word =

a)

16 bytes

b)

16 KB

c)

8 bits

4.

Full form of ADC is

a)

Analog to Data Converter

b)

Analog to Digital Converter

c)

Amplitude to Digital Converter

5.

1 byte =

a)

16 bytes

b)

16 KB

c)

8 bits

6.

A binary number with one digit is called a ____

a)

Bit

b)

byte

c)

Word

7.

Analog signal can be converted to Digital values using

a)

Resolution

b)

Sampling

c)

Memory Allocation

8.

The A/D converter samples the amplitude of the analog signal at

a)

Discrete intervals

b)

Discrete function

c)

maximum range

9.

three types of analog signals in PLC programming___ ____ ____

a)

Voltage, Current & Resistance

b)

Voltage, Current & Transistor

c)

Resistor, Current & Transistor

10.

the process of mapping continuous infinite values to a smaller set of discrete finite values is ______

a)

Resolution

b)

Quantization

c)

Sampling

11.

The number of bits used to represent the analog input defines

a)

Resolution

b)

Range

c)

Sampling

12.

PLC Value 27648 represents 10V analog signal. calculate the real resolution of our analog signal.

a)

361.7 μV

b)

367.7 μV

c)

369.7 μV

13.

In Siemens PLC, what is Overshoot Range?

a)

22.86 mA

b)

22.96 mA

c)

22.81 mA

14.

In Siemens PLC, what is Undershoot Range?

a)

1.815 mA

b)

1.885 mA

c)

1.15 mA

15.

In Siemens PLC, what is Overflow Range?

a)

22.86 mA

b)

22.96 mA

c)

22.81 mA

16.

Wiring of Analog signals is categorised into?

a)

Voltage and Resistance

b)

Voltage and Current

c)

Resistance and Current

17.

Which of the following is example for input analog sensors and transmitters.

a)

Submersible Level Transmitters

b)

Pressure Transmitter

c)

Temperature Sensor

18.

Temperature transmitter with a 4-20 mA output. Connected to the transmitter is a temperature sensor. The transmitter is then calibrated to a range

a)

4 mA

b)

12mA

c)

16mA

19.

What is common between both voltage and current analog signal wiring?

a)

Temperature

b)

Resistance

c)

Reactance

20.

Analog voltage inputs has two terminals, what are those?

a)

AGND and AI

b)

PAIN and AG

c)

AGAIN and AGND

21.

All electrical wires (conductors) have resistance and hence creating a ____ drop.when you have as long as distances of wiring.

a)

Current

b)

Resistance

c)

Voltage

22.

PLC analog module terminal AIN is connected to______terminal of voltage source.

a)

Positive(+)

b)

Negative(-)

c)

Ground

23.

PLC analog module terminal AGND is connected to______terminal of voltage source.

a)

Positive(+)

b)

Negative(-)

c)

Ground

24.

Which terminal is used as reference for our analog signal?

a)

AIN

b)

AGND

c)

AI

25.

How can we reduce the effect of Electromagnetic Interference?

a)

Sampling

b)

Shielding

c)

EMC

26.

The current in analog signals is usually measured in _____unit

a)

Resistance

b)

Voltage

c)

Amperes (A)

27.

A resistor is put between positive (AI) and negative (AGND). This will converts our current signal to a voltage signal. This resistor called as___

a)

Capacitor

b)

Closed loop

c)

Voltage drop

28.

What is the resistance of shunt resistor in Siemens analog input module.

a)

300 Ohm

b)

250 Ohm

c)

350 Ohm

29.

Which analog input Wiring method separates the supply from the signal

a)

2-wire Analog Input

b)

3-wire Analog Input

c)

4-wire Analog Input

30.

convert the raw value from the analog input to some sort of engineering value Is

a)

unscaling

b)

scaling

c)

both a and b

31.

Example for engineering value is

a)

ampere

b)

volt

c)

resistence

32.

The block used for scaling in PLC is

a)

FC 107

b)

FC 106

c)

FC 105

33.

FC 105 has -------- inputs

a)

3

b)

2

c)

5

34.

The range of Raw value in siemens plc is

a)

0-376

b)

500-27648

c)

0-27248

35.

Example for Analog outputs for PLC are

a)

motor

b)

sensor

c)

valve

36.

PLC Analog outputs need ------------ Signal

a)

discrete signal

b)

pulse signal

c)

continuous

37.

Wiring of Voltage and Current IS same in PLC

a)

TRUE

b)

FALSE

c)

both a and b

38.

Wiring of Voltage and Current is depends on

a)

input

b)

sensor

c)

plc

39.

Voltage Output consist of how many terminal

a)

2

b)

3

c)

4

40.

opposition that a circuit presents to changes in current or voltage

a)

flux

b)

density

c)

line impedence

41.

Two extra terminals are used in voltage analog output wiring

a)

for load

b)

for compensating

c)

for signal

42.

Minimum load impedance in Voltage wiring is

a)

500 Ohm

b)

1k ohm

c)

300 ohm

43.

if we want to generate 8ma signal from plc what value should be given D to A converter

a)

76

b)

128

c)

1069

44.

The need of scaling function in PLC

a)

for processing

b)

to show the measurement on an HMI.

c)

It is convenient to work with the engineering value

45.

The need of unscaling function in PLC module can convert to an output

a)

for processing

b)

to show the measurement on an HMI.

c)