Motors Final Review 0 RF

Total questions: 50

Worksheet time: 8hrs 33mins

Name
Class
Date
1.

Electric motors in HVAC are ususally used to turn the prime movers of air, water, and ________.

a)

Refrigerant

b)

Acids

c)

Smoke

d)

Solids

2.

Fans move____ pumps move ____.

a)

water, air

b)

refrigerant, water

c)

air, water

d)

magnetism, electricity

3.

Shaded pole motors have a high level of torque compared to single phase motors.

a)

True

b)

False

4.

Electric motors have a stator with windings, a _____, bearings, end bells, housing, and some means to hold these parts in the proper position.

a)

rotor

b)

sleave

c)

gasket

d)

wires

5.

The motor _____ is connected to the rotor; therefore, when the rotor turns, so does the motor _____.

a)

shaft

b)

rod

c)

stator

d)

shank

6.

The technician must understand which motor is suitable for each job in order to troubleshoot effectively and, if necessary, to replace a motor with the proper type.

a)

true

b)

false

7.

115-V is single-phase voltage for household appliances

a)

True

b)

False

8.

A motor that runs a refrigeration compressor must have a high starting _____.

a)
torque
b)

amps

c)

ohms

d)

horsepower

9.

a/an alternating current motor where the rotor turns from induced magnetism from the field windings.

a)

Induction motor

b)

reduction motor

c)

capacitive motor

d)

impedance motor

10.

Excessive motor slip can be an indication of proper motor lubrication, effective motor bearings, greatly adjusted belts , or properly selected motor for the desired application.

a)

False

b)

True

11.

_______ is the component in a motor that contains the windings: it does not turn.

a)
stator
b)

rotor

c)

mount

d)

capacitor

12.

LRA is also referred to a inrush amps

a)

True

b)

False

13.

A centrifugal switch allows the run windings to be taken out of the circuit once the motor has reached 75% of it's running capacity.

a)

True

b)

False

14.

The rotating portion of the motor is call the _____.

a)

stator

b)

end bells

c)

rotor

d)

induction motor

15.

Capacitors ensure that a single phase motor rotates in a certain direction every time.

a)

True

b)

False

16.

Bearings help reduce the friction of the rotor.

a)

True

b)

False

17.

Single phase motors only rotate well in a counter-clock wise motion.

a)

True

b)

False

18.

In the USA, AC power is supplied at a frequency of ____ hertz.

a)

55

b)

62

c)

75

d)

60

19.

Synchronous speed refers to the speed with a load.

a)

True

b)

False

20.

Motor slip represents the difference between the motor's ____ and ____ speeds.

a)

size, phase

b)

calculated, actural

c)

slip, stationary

d)

high, low

21.

Poorly adjusted belts do not affect motor slip.

a)

True

b)

False

22.

The start windings have the most ____.

a)
voltage
b)
current
c)
resistance
d)
turns
23.

This arrow is pointing to the ___ winding.

a)

start

b)

secondary

c)

run

d)

primarry

24.

Inductions motors induce magnetism.

a)

True

b)

False

25.

Many split-phase motors run a ____ RPM.

a)

3500

b)

1600

c)

1800

d)

800

26.

Torque refers to ____ power.

a)

capacitor

b)

pulling

c)

twisting

d)

cooling

27.

LRA is voltage seen at start up.

a)

True

b)

False

28.

LRA is also called ___ amps.

a)

outrush

b)

motor

c)

inrush

d)

stationary

29.

This greek letter is used to refer to ____.

a)

amps

b)

phase

c)

poles

d)

inrush current

30.

Three phase power is common in residential applications.

a)

True

b)

False

31.

Control voltage is ____ volts.

a)

30

b)

24

c)

75

d)

115

32.

This arrow is pointing to the ____ winding.

a)

start

b)

low voltage

c)

run

d)

the phase

33.

Changing the charge of the poles (polarity) can change the ____ or the motor.

a)
speed
b)

rotation

c)
size
d)

efficiency

34.

Split-phase motors ______.

a)

have no windings

b)

have start and run windings

c)

have single and three phase winding

d)

have large windings

35.

A centrifugal switch disconnects the start winding when the motor has reached ____% of the rated speed.

a)

80

b)

55

c)

75

d)

100

36.

The centrifugal switch is used in all motors.

a)

True

b)

False

37.

This component is the ____.

a)

capacitor

b)

fan module

c)

fan board

d)

psc motor

38.

This type of motor is call a ____.

a)

ECM

b)

PSC

39.

PSC motors have capacitors.

a)

True

b)

False

40.

This image shows a ____.

a)

centrifugal swithc

b)

stator

c)

capacitor

d)

integrated circut

41.

Capacitors are measured in ____.

a)

micrometers

b)

voltage

c)

macrofards

d)

microfarads

42.

How many microfarads is this capacitor?

a)

10

b)

45/5

c)

5

d)

it is not a capacitor

43.

Capacitors are like ____.

a)

motors

b)

batteries

c)

rotors

d)

compressors

44.

HERM on a capacitor refers to ____.

a)

Evaporator coil

b)

Start winding

c)

Compressor

d)

Run winding

45.

Ground is the same a common in an electrical circuit.

a)

True

b)

False

46.

All motors must be cooled because part of the electrical energy input to the motor is given off as heat.

a)

True

b)

False

47.

The ECM motor is calibrated at the factory to suit the piece of equipment.

a)

True

b)

False

48.

Diodes let current pass in any direction.

a)

True

b)

False

49.

An inverter changes AC to DC.

a)

True

b)

False

50.

This type of motor does not use 24v to communicate.

a)

True