wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

AEU Knowledge Check

Total questions: 13

Worksheet time: 26mins

Name
Class
Date
1.

What is the length of the CCM Address Extension Unit - AEU (ATU-PVT-SBM1)?

a)

690 mm

b)

310 mm

c)

500 mm

d)

1000 mm

e)

800 mm

2.

How many CCM units does the AEU (ATU-PVT-SBM1) count for power supply calculation?

a)

5 units

b)

3 units

c)

4 units

d)

1 unit

e)

2 units

3.

Which units can be installed downstream of AEU (ATU-PVT-SBM1)?

Choose all that apply.

a)

ATU-PVT-TT

b)

ATU-PVT-LC (03, 05, 07, 10)

c)

ATU-PVT-SBM1

d)

ATU-PVT-LBF05

e)

ATU-PVT-AOB

4.

What are the benefits of using the AEU (ATU-PVT-SBM1) in a CCM Solution?

Choose all that apply.

a)

Fast rerun before storing or sending out the rack

b)

Optimized distribution of rack among mirrored systems

c)

Creation of a rack-position link sent to middleware

d)

Increase the number of possible primary targets (analyzers) reached by the rack

e)

More efficient add-on testing as recursive flowMore efficient add-on testing as recursive flow

5.

What happens when ALL 5 sample tubes AND rack barcodes cannot be identified?

a)

Independent from the AEU settings, it will always trigger a STOP alarm

b)

It will always send the rack to the configured default destination 

c)

Rack will be sent to the upstream unit connected to AEU

d)

Rack will be forwarded to the same path as received from upstream CCM unit

e)

Depending on the  AEU settings, it can either display a STOP alarm or forward the rack to the configured default destination

6.

What is the purpose of the barcode labels brackets located on the pull-in conveyor of AEU (ATU-PVT-SBM1)?

a)

To inform the rack ID

b)

To detect / inform, if the specific rack position is empty or occupied by sample tube

c)

To inform the sample ID

d)

To adjust the rack ID barcode reader

e)

To adjust the sample ID barcode reader

7.

Which functionalities apply to the AEU (ATU-PVT-SBM1)?
Choose all that apply.

a)

Rack barcode identification

b)

Communication to middleware

c)

Assignment of new path to racks

d)

Communication to analyzer

e)

Availability of path (rack-jam/RTR signal) is sent to middleware

8.

Which procedure must be performed after replacing the rack ID barcode reader with a new one?
Choose all that apply.

a)

Self-driven BCR reading stop position adjustment

b)

Configuration of the readable barcode types

c)

Rack ID reading position adjustment

d)

Rack ID BCR initial setting

e)

Self-driven BCR reading start position adjustment

9.

What is the jumper setting for JP610 on the drive board UN201 to "bridge" the sensor of the protective cover during the adjustment procedure?

a)

JP610 to 2-3 short

b)

JP610 to 1-2 short

c)

JP610 3-4 short

10.

What is the expected time for AEU to receive the "Respond Path Message"  from middleware?

a)

10 ms

b)

7 s

c)

30 ms

d)

10 s

e)

12 s

11.

Is the timeout to receive the "Respond Path Message" of the AEU configurable?

a)

No

b)

Yes

c)

Depends on the AEU mode (initial rack pairing or normal mode)

12.

The offline button is activated on the AEU (ATU-PVT-SBM1). Which statements regarding the unit behavior are correct?
Choose all that apply.

a)

If initial-rack pairing mode is configured, rack will be forwarded to the configured default destination address

b)

If normal mode is configured, rack will remain on the AEU

c)

If initial-rack pairing mode is configured, rack will be forwarded to the same path received from the upstream unit

d)

If initial rack pairing mode is configured, the rack will remain on AEU

e)

If normal mode is configured, rack will be forwarded to the configured default destination address

13.

What kind of information is exchanged between the AEU (ATU-PVT-SBM1) and the middleware?
Choose all that apply.

a)

Patient specific data (name, age, tests, etc)

b)

Rack ID and sample ID

c)

Sample tube position on rack

d)

Path availability (rack-jam / RTR signal) from downstream units of AEU

e)

New destination (path number) assigned to the rack