wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

309 Sanitation systems 1 Quiz

Total questions: 24

Worksheet time: 12mins

Name
Class
Date
1.

If a macerator ran for a long time after flushing, what could be the problem?

a)

Blockage in the area of the pump within the unit

b)

Excessive volume of solids

c)

Incorrect electrical connection

d)

Timer requiring resetting

2.

Where can appliance discharge rates be obtained?

a)

The data plate on an appliance

b)

British Standards

c)

The clerk of the works

d)

The Building Regulations

3.

If a waste water lifter pump began to cycle on and off, what could be the reason?

a)

Intermittent electrical fault on the supply connection

b)

Excessive volume of waste being processed

c)

A dripping tap or leaking connection in the house

d)

A designed self-priming process

4.

When servicing a sink waste disposal unit, you discover an excessive amount of debris in the unit. How would you proceed?

a)

Safely isolate the unit and remove the debris

b)

Ask the end user questions to ascertain the origin of the debris

c)

Safely isolate the unit and decommission

d)

Flush with clear water

5.

Which of the following make an air admittance valve (AAV) unsuitable for sanitary pipework installations?

a)

Venting to atmosphere at intermittent points on the run of the drain

b)

The inclusion of a stub stack

c)

An interceptor trap

d)

A waste water lifter

6.

Which of the following best describes a cesspool?

a)

An installation which processes solids and liquids

b)

A pit where debris naturally permeates into the water table

c)

A receptacle which stores effluent that is later used as a fertiliser

d)

An installation that stores solids and liquids that are removed at a later date

7.

Who should be consulted before the beginning of servicing or any type of remedial work on a sanitary appliance?

a)

The local authority

b)

The manufacturer

c)

The customer

d)

The previous installer

8.

If a problem has been reported about the operation of a waste water lifter, what would be the first step to take to help analyse the issue?

a)

Talk to the previous installer and seek their advice

b)

Order parts based on discussion with the client

c)

Do not operate appliance; dismantle basic components

d)

After talking with the customer, operate the appliance and check for operation, in accordance with the manufacturer’s instructions

9.

How should the floor surface of a walk-in wet room be installed?

a)

On a flat plane

b)

With an angle which falls to a central or perimeter gully

c)

With non-porous tiles

d)

With a fallout of the wet room area to an external gully

10.

How much trap seal should remain after the full performance testing procedure has been completed?

a)

10mm

b)

50mm

c)

75mm

d)

25mm

11.

Which of the following sentences could best describe safe electrical isolation of a macerator?

a)

Remove electrical wire from macerator unit and make safe in strip connector

b)

Turn off rocker switch

c)

Remove the fuse from spur outlet in the wall

d)

Remove the fuse from spur outlet, turn off and lock MCB at consumer unit, and leave a sign. Keep any components capable of accidentally reconnecting the electrical supply in a safe place on your person

12.

Spacing requirements for people to move safely and comfortably in bathrooms can be found in which standard?

a)

BS EN 120156

b)

BS EN 12380

c)

BS 6700

d)

BS 6465

13.

What minimum distance is required in front of a close coupled WC?

a)

800mm

b)

600mm

c)

1,350mm

d)

750mm

14.

What is the name of the process which ensures that a walk-in wet room does not leak?

a)

Encapsulation

b)

Intumescent sealing

c)

Tanking

d)

Silicone sealing

15.

Which of the components mentioned below could require regular replacement on a WC macerator?

a)

Impeller

b)

Fused spur

c)

Carbon filter

d)

NRV

16.

Discharge units are used to calculate which of the following?

a)

The output of the appliances

b)

The cost of the installation

c)

The size of the soil stack

d)

The self-cleansing velocity of the whole system under full flow

17.

If a length of pipework was too long on a waste water lifter, which of the following situations could occur?

a)

The motor would continue to run after the water has been drawn off

b)

Water hammer would begin to develop

c)

Loud gurgling and popping noises would be emitted from appliances

d)

A vacuum would develop in appliance wastes

18.

When calculating stack sizes, what does the term ‘K’ refer to?

a)

Discharge units

b)

Flow rates

c)

Frequency factor

d)

Hydraulic capacity

19.

What is the minimum space provision in front of an enclosed shower tray?

a)

700mm

b)

800mm

c)

900mm

d)

950mm

20.

What effect does increasing the gradient of the discharge branch pipe have on its permissible length?

a)

It will increase

b)

It will decrease

c)

It has no effect

d)

All gradients must be fixed at 22mm/m

21.

Which two of the following factors are least likely to be considered during the selection of sanitary appliances for a new bathroom?

a)

Cost

b)

Country of manufacture

c)

Space temperature

d)

Availability

e)

Client’s taste

22.

The trap in the image below can be used to prevent trap seal loss caused by what fault?

a)

Evaporation

b)

Wavering out

c)

Self-siphonage

d)

Compression

23.

If an architect places an advertisement in a building journal or newspaper to invite contractors to submit tenders within a specified time for plumbing work, what type of tendering is taking place?

a)

Open tendering

b)

Closed tendering

c)

Selective tendering

d)

Repeat tendering

24.

Clear information regarding the proposed costs and charges should be included in a quote for plumbing work to help prevent what?

a)

Disagreements between client and plumber regarding end costs

b)

Disagreements between client and plumber regarding timings

c)

Disagreements between client and supplier regarding end costs

d)

Disagreements between client and supplier regarding timings