Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

PPT Functional testing of electrical components within plumbing

Total questions: 44

Worksheet time: 22mins

Name
Class
Date
1.

Who should carry out full electrical testing ?

a)

A plumber

b)

A competent and suitably qualified electrician

c)

A Part P qualified operative

d)

Any qualified tradesperson

2.

What type of checks can a plumber perform?

a)

Full electrical testing

b)

Testing of a new fused spur unit

c)

Simple checks for safe isolation, continuity, and polarity

d)

Installation of a new boiler

3.

Who is required to test a new fused spur unit feeding a boiler?

a)

A plumber

b)

A competent and suitably qualified electrician

c)

A Part P qualified operative

d)

Any qualified tradesperson

4.

What does a plumber not need to be Part P qualified to change?

a)

A new boiler

b)

A like-for-like component such as a pump or flex cable to a boiler

c)

A new electrical circuit

d)

A gas line

5.

What must be ensured about leads, probes, and instruments before testing begins?

a)

They are new and shiny.

b)

They are in good condition and undamaged.

c)

They are expensive and branded.

d)

They are lightweight and portable.

6.

What does HSE guidance note GS38 provide?

a)

Instructions on how to repair electrical equipment.

b)

Guidance on safe and suitable use of electrical test equipment.

c)

Tips on how to sell electrical equipment.

d)

Information on the history of electrical equipment.

7.

What should the test probe of any instrument not be?

a)

Expensive to replace.

b)

A hazard to the user.

c)

Difficult to use.

d)

Made of plastic.

8.

What should be the maximum length of exposed conductor ?

a)

6mm

b)

4mm

c)

8mm

d)

10mm

9.

Why should the leads have a barrier ?

a)

To enhance conductivity

b)

To prevent access to terminals

c)

To reduce weight

d)

To improve flexibility

10.

What should be clearly marked on the equipment?

a)

The manufacturing date

b)

The maximum voltage and current

c)

The brand name

d)

The warranty period

11.

What is the purpose of using a proving unit with a voltage indicator?

a)

To confirm the correct operation of the voltage indicator

b)

To increase the voltage output

c)

To decrease the voltage input

d)

To replace the voltage indicator

12.

Which guidance should the voltage indicator and proving unit conform to?

a)

HSE document GS38

b)

HSE document GS40

c)

HSE document GS35

d)

HSE document GS50

13.

What is one of the primary uses of a multimeter?

a)

Measuring temperature

b)

Measuring pressure

c)

Measuring electrical resistance

d)

Measuring sound levels

14.

Which settings on a multimeter are used to check if a cable has gone open circuit?

a)

Voltage setting

b)

Current setting

c)

Resistance setting

d)

Frequency setting

15.

What can a multimeter check regarding a motor or zone valve?

a)

If it is overheating

b)

If it has burnt out

c)

If it is leaking

d)

If it is vibrating

16.

What is the primary use of a multimeter as shown in the image?

a)

Measuring voltage

b)

Measuring temperature

c)

Measuring speed

d)

Measuring weight

17.

How is the current measured ?

a)

In parallel with the load

b)

In series with the load

c)

Independently from the load

d)

Across the load

18.

What is the primary function of a digital clamp meter?

a)

To measure voltage in a circuit

b)

To give a real-time indication of run current

c)

To measure resistance in a circuit

d)

To provide a digital display of temperature

19.

Why are digital clamp meters ideal for use in the maintenance of appliances?

a)

They are lightweight and portable

b)

They can measure temperature changes

c)

They provide real-time current readings

d)

They are inexpensive

20.

What does the clamp meter read and interpret in a live conductor?

a)

Voltage levels

b)

Magnetic field produced by current flow

c)

Temperature variations

d)

Resistance levels

21.

Who typically carries out an insulation resistance test?

a)

A plumber

b)

A competent electrician

c)

A carpenter

d)

A painter

22.

What is electrical impedance?

a)

The amount of opposition an electrical circuit offers to current or voltage change.

b)

The speed at which current flows through a circuit.

c)

The total voltage in a circuit.

d)

The power consumed by a circuit.

23.

Which device is used to measure the impedance of a live electrical circuit?

a)

Continuity tester

b)

Earth loop tester

c)

Voltage meter

d)

Ammeter

24.

Who should carry out the test for measuring impedance in a live electrical circuit?

a)

A competent electrician

b)

A plumber

c)

A carpenter

d)

A painter

25.

What is the aim of testing the impedance of the whole earth fault current loop?

a)

To ensure the system is grounded properly

b)

To verify if it is low enough to enable overcurrent protective devices to operate within their designed time requirements

c)

To check the voltage levels in the circuit

d)

To measure the current flow in the circuit

26.

Which of the following is a part of the earth loop starting at the point of the fault?

a)

Circuit protective conductor

b)

Insulated neutral conductor

c)

Overhead power line

d)

Underground cable

27.

What does the symbol Zs represent in the context of earth loop impedance?

a)

Voltage

b)

Current

c)

Impedance

d)

Resistance

28.

In TN-S systems, which component is part of the earth loop?

a)

Supply earth

b)

Supply neutral

c)

Supply phase

d)

Supply transformer

29.

The impedance of the fault path is measured in which unit?

a)

Volts

b)

Amperes

c)

Ohms

d)

Watts

30.

What is the primary function of a socket tester?

a)

To check for polarity and identify reversed connections

b)

To measure voltage levels

c)

To test circuit breakers

d)

To install new sockets

31.

What are the two types of electrical testing mentioned in the document?

a)

Dead and live

b)

Static and dynamic

c)

Active and passive

d)

Hot and cold

32.

What is the characteristic of dead tests in electrical testing?

a)

Electrical power is on

b)

Electrical power is off

c)

Conducted in water

d)

Conducted in air

33.

According to BS:7671: 2018, when must live tests be carried out?

a)

On plumbing installations

b)

On electrical installations

c)

On mechanical installations

d)

On thermal installations

34.

Who is allowed to undertake electrical testing and certification according to the document?

a)

Any electrician

b)

Only operatives registered for Part P of the Building Regulations

c)

Any construction worker

d)

Only engineers with a PhD

35.

What is the purpose of a visual inspection before testing in plumbing and domestic heating?

a)

To ensure the system is installed according to standards and has no visible damage.

b)

To check the water pressure levels.

c)

To verify the color of the pipes.

d)

To measure the temperature of the system.

36.

What does checking for correct polarity involve?

a)

Ensuring conductors are securely fitted and in the correct terminals.

b)

Measuring the voltage of the system.

c)

Checking the color coding of the wires.

d)

Testing the system's resistance.

37.

Which test instrument is used for checking the continuity of earth conductors?

a)

Insulation Resistance Tester

b)

High reading Ohmmeter

c)

Low reading Ohmmeter

d)

Voltage Tester

38.

What is the correct sequence for conducting dead tests before a live test?

a)

Polarity, Insulation resistance, Continuity of final ring conductors, Continuity of earth conductors

b)

Continuity of earth conductors, Continuity of final ring conductors, Insulation resistance, Polarity

c)

Insulation resistance, Continuity of earth conductors, Polarity, Continuity of final ring conductors

d)

Continuity of final ring conductors, Polarity, Continuity of earth conductors, Insulation resistance

39.

Which test uses an Insulation Resistance Tester?

a)

Continuity of earth conductors

b)

Continuity of final ring conductors

c)

Insulation resistance

d)

Polarity

40.

Why should a dead test be carried out before a live test?

a)

To save time

b)

To ensure safety and correct sequence

c)

To reduce costs

d)

To increase efficiency

41.

Which instrument is used for testing polarity in live test sequences?

a)

Earth Loop Impedance Tester

b)

Prospective fault current Tester

c)

RCD tester

d)

GS 38 Approved Test leads

42.

What is the correct instrument for testing Earth Electrode Resistance?

a)

GS 38 Approved Test leads

b)

Earth Loop Impedance Tester

c)

Prospective fault current Tester

d)

RCD tester

43.

Which test uses the Prospective fault current Tester?

a)

Polarity

b)

Earth Fault Loop Impedance

c)

Prospective fault current

d)

Functional Testing

44.

For which test is the RCD tester used?

a)

Earth Electrode Resistance

b)

Functional Testing

c)

Polarity

d)

Earth Fault Loop Impedance