NEW
Font size
WorksheetsBlock 12v2
Total questions: 47
Worksheet time: 24mins
The receiver of the A/M32C-5 holds ___ IBS of liquid refrigerant for operation
50
100
75
25
The ___ will ensure only liquid refrigerant is drawn from the receiver
Dip Tube
Sight Glass
Compressor
Evaporator
What component provides a way to visually observe the flow and condition of the liquid refrigerant
Dip Tube
Sight Glass
Sight Tube
Evaporator
The receiver is only filled to 80% to leave room from ____
Thermal expansion
Maintenance or Cleaning
Air Circulation
Flash Gas
Relief Valve opens at ____
450 PSI
350 PSI
35 PSI
290 PSI
Which of the following describes the function of the front-seated position of the manual service valve?
Valve Up, used during normal operations (isolates charge port)
Valve Down, Used to isolate receiver for maintenance
4 turns back from seated position, used to remove or charge system with refrigerant
Used to remove liquid refrigerant from receiver
Which of the following describes the function of the back-seated position of the manual service valve?
Valve Up, used during normal operations (isolates charge port)
Valve Down, Used to isolate receiver for maintenance
4 turns back from seated position, used to remove or charge system with refrigerant
Used to remove liquid refrigerant from receiver
Which of the following describes the function of the gauge position of the manual service valve?
Valve Up, used during normal operations (isolates charge port)
Valve Down, Used to isolate receiver for maintenance
4 turns back from seated position, used to remove or charge system with refrigerant
Used to remove liquid refrigerant from receiver
What is used to add liquid refrigerant to the receiver
High Side Charging Port (Receiver Inlet)
Receiver Outlet Valve
Sub-Cooler Coil
Compressor
What is used to remove liquid refrigerant to the receiver
High Side Charging Port (Receiver Inlet)
Receiver Outlet Valve
Sub-Cooler Coil
Compressor
___ uses condenser fan to draw ambient air across the coils and ensures only liquid refrigerant goes to the evaporator and prevents flash gas
Sub-Cooler Coil
Evaporator Coils
Compressor
Filter/Drier
___ removes moisture & foreign particles from liquid refrigerant
Sub-Cooler Coil
Evaporator Coils
Compressor
Filter/Drier
What 3 things does the Filter/Drier prevent?
Icing of Expansion Valve, Hydrofluoric acid formation, Corrosion of system tubing
Refrigerant leaks, system overheating, compressor wear
Excess pressure buildup, moisture accumulation, improper lubrication
Blockage of refrigerant flow, oil contamination, freezing of refrigerant
____ prevents migration of liquid refrigerant into compressors in the event of a sudden electrical power outage during operation
Filter/Drier
TXV Solenoid Valve
Sight Glass
Evaporator
What meters the amount of liquid refrigerant entering evaporator
Expansion Valve
Evaporator Gauge
Refrigerant Gauge
Compressor
The expansion valve changes ___ to ___ to absorb heat in evaporator
HPL to LPL
LPL to HPL
HPG to LPG
LPG to HPG
Expansion valve ______ & _____ of liquid refrigerant
Lowers pressure & temperature
Increases pressure & temperature
Supply’s & Cleaning
Removes & Cleaning
Expansion valve position is controlled by?
B7
R1
TT3
TC
____ receives information from 5 components
B7
R1
TT3
TC
TC receives information from what 5 components to manage the refrigerant process
PT1, R1, TT1, TT2, TT3
PT1, PT2, R1, B7, TT1
B7, R1, TT1, TT2, TT3
PT1, PT2, R1, B7, S4
____ is used by the operator to set desired output air temperature
B7
R1
TT3
TC
____ measures air temperature entering the evaporator
B7
TT2
TT3
TT1
____ measures air temperature leaving the evaporator
B7
TT2
TT3
TT1
____ measures refrigerant suction temperature leaving evaporator
B7
TT2
TT3
TT1
____ is a pressure transducer that measures refrigerant suction pressure
PT1
TT2
TT3
TC
What are the 4 sub systems that the Electronic Temperature Control controls
Compressors, B7, V1, S1
Compressors, B7, S1, TT1
PT1, R1, TT1, TT2, TT3
V1, S1, S4, B7
___ refrigerant enters evaporator coil from expansion valve
LPL
HPL
LPG
HPG
____ is directed across the outside of evaporator coil
Ambient air
Refrigerant
Heat
Coolant
LPL absorbs heat, causing it to ___ within the evaporator coil
Boil into a LPG
Boil into a HPG
Boil into a HPL
Stay cooled as a LPL
___ continues to absorb ___ as it flows through the evaporator coil
LPG, Superheat
LPL, Superheat
HPG, Coolant
LPG, Coolant
What are the 4 heat load factors
Humidity, Amount of air cooled, Starting air temperature & Desired air temperature
Air circulation rate, system efficiency, external temperature, heat source proximity
Humidity, insulation quality, equipment size, airflow direction
Temperature, Circulation, Humidity & Purity
What valve is used to isolate the compressors
Relief Valve
Isolation Valve
Compressor Inlet & Outlet Vlaves
Quench Valve
____ increase the pressure & temperature of refrigerant gas so it will condense at ambient temperature (LPG to HPG)
Compressors
Evaporator
Expansion Valve
Pumpdown
What separates oil from gas refrigerant and returns oil to inlet side of compressor
Filter/Drier
Oil Separator
Sub-cooler
Gas Separator
____ from compressors enters 2 condenser coils
Superheated HPL
Superheated HPG
Superheated LPG
Superheated LPL
High Pressure Cutout (HPCO) opens at 290 psi of refrigerant discharge pressure to shut off ____
Both Compressors
Condenser Fan
Electronic Temperature Controller
Sub-Cooler
Quench Valve senses refrigerant discharge temperature using a ____
Sensing Bulb
Meter
Color changing dot
Thermometer
Quench valve prevents?
Thermal Breakdown of compressor Oil
Overheating of the refrigerant system
Excessive pressure in the discharge line
Moisture contamination in the system
Thermal Break down of compressor oil starts at?
200°F
150°F
250°F
75°F
____ is controlled by TC to keep suction pressure above 28 psi during normal operation
High Pressure Cutout (HPCO)
Hot Gas Bypass Valve (HGBP) & S1
Condenser Fan Cycle Switch
Low Pressure Cutout (LPCO)
____ will prevent low side of the system from being drawn into a vacuum, preventing inward leaks
High Pressure Cutout (HPCO)
Hot Gas Bypass Valve (HGBP) & S1
Condenser Fan Cycle Switch
Low Pressure Cutout (LPCO)
LPCO stops the compressor when suction pressure drops to ___
5 psi
10 psi
8 psi
12 psi
____ is used by TC to determine pump down effectiveness
HGBP
HPCO
LPCO
Quench Valve
What term is used to describe the amount of heat energy that needs to be moved in order to achieve the desired outcome?
Flash Gas
Superheat
Heat Load
Humidity
What provides the temperature suction pressure information
PT1
TT2
TT3
TC
The A/M32C-5 uses 2 hermetically sealed ____ to increase the temperature and pressure of the vapor refrigerant
Expansion Valve
Condenser Coil
Compressors
Condenser fans
The A/M32C-5 has two ____ that will allow heat to be extracted from the superheated, high pressure refrigerant vapor causing a change in state from a vapor to a high pressure liquid
Expansion Valve
Condenser Coil
Compressors
Condenser fans
