PPT 3 - Pipework & Circulation COL

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

What is the primary function of a vent pipe in a plumbing system?

a)

To increase water pressure

b)

To act as a safety relief if the system overheats

c)

To filter impurities from water

d)

To reduce noise in the pipes

2.

What type of valve is used in a direct plumbing system for full-way control?

a)

Ball valve

b)

Check valve

c)

Gate valve

d)

Pressure valve

3.

Where should the vent pipe be located in relation to the cold feed cistern?

a)

Below the cold feed cistern

b)

At the same level as the cold feed cistern

c)

Above the cold feed cistern in the roof space

d)

Inside the cold feed cistern

4.

How far should the vent pipe terminate above the top of the float valve?

a)

At least twice the internal diameter of the vent pipe

b)

At least the same as the internal diameter of the vent pipe

c)

At least half the internal diameter of the vent pipe

d)

At least three times the internal diameter of the vent pipe

5.

What is the formula to determine the minimum height of the top of a vent pipe above the top of the overflow pipe?

a)

V = 0.04H + 0.15

b)

V = 0.15H + 0.04

c)

V = 0.04H - 0.15

d)

V = 0.15H - 0.04

6.

In what type of circulation system does the minimum height of the vent pipe apply?

a)

Gravity circulation systems

b)

Forced circulation systems

c)

Closed loop systems

d)

Open loop systems

7.

According to British Standards, what should be done if valves are found on the route of the vent pipe?

a)

They must be removed

b)

They must be replaced

c)

They must be adjusted

d)

They must be left as is

8.

What causes one-pipe circulation in plumbing systems?

a)

Hot water rising and cooling near the pipe walls

b)

Cold water rising and heating near the pipe walls

c)

Hot water remaining static in the pipe

d)

Cold water circulating without heating

9.

What is the minimum distance the hot water distribution pipe must be from the top of the cylinder to the vent?

a)

300mm

b)

450mm

c)

600mm

d)

750mm

10.

What is the purpose of having a rise in the pipework?

a)

To increase water pressure

b)

To allow air to escape via the vent pipe

c)

To decrease water temperature

d)

To reduce pipe length

11.

What is used to minimize heat loss in the plumbing system according to Building regulations part 'L'?

a)

Ventilation

b)

Insulation

c)

Filtration

d)

Evaporation

12.

Why is it important to control the length of pipe used to deliver hot water to the outlet?

a)

To increase water pressure

b)

To avoid waste of cold water and cooling of hot water

c)

To reduce noise

d)

To prevent pipe corrosion

13.

According to British Standards, what is the maximum length of a pipe with a diameter of 12–22mm before it becomes a 'dead leg'?

a)

8m

b)

12m

c)

3m

d)

15m

14.

Why must passive dead legs be kept to a minimum length?

a)

To save energy

b)

To prevent Legionella and bacterial growth

c)

To increase water pressure

d)

To reduce noise in the pipes

15.

Where does the return pipe enter the cylinder in a secondary circulation system?

a)

At the top of the cylinder

b)

At the bottom of the cylinder

c)

Approximately one-third of the way down

d)

Halfway down the cylinder