wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Hot Water - PPT 5 - Showers

Total questions: 30

Worksheet time: 15mins

Name
Class
Date
1.

Which of the following is a type of shower mixer valve?

a)

Gravity mixer

b)

Pressure valve

c)

Thermal mixer

d)

Rotary valve

2.

What is one classification of shower mixer valves?

a)

Mains-fed/boosted mixer

b)

Hydraulic mixer

c)

Solar mixer

d)

Pneumatic mixer

3.

What is the purpose of having the cold water feed to the cylinder higher than the cold for the shower in a cistern-fed/gravity mixer system?

a)

To ensure the cold water runs out first

b)

To ensure the hot water runs out first

c)

To balance the water pressure

d)

To reduce water temperature

4.

What is the minimum head required for the shower mixer valve in a cistern-fed/gravity mixer system?

a)

0.5m

b)

1m

c)

1.5m

d)

2m

5.

What is the recommended pipe size before reducing to 15mm in a cistern-fed/gravity mixer system?

a)

10mm

b)

15mm

c)

22mm

d)

30mm

6.

What is required for a cistern-fed/gravity mixer to function properly?

a)

Unequal pressure

b)

Equal pressure

c)

High pressure

d)

No pressure

7.

From where are both the hot and cold water fed in a cistern-fed/gravity mixer?

a)

Directly from the mains

b)

From the CWSC

c)

From a separate tank

d)

From a boiler

8.

What is the minimum head required from the base of the CWSC to the outlet of the shower rose?

a)

0.5m

b)

1m

c)

1.5m

d)

2m

9.

What is the function of a thermostatic valve in a cistern-fed/gravity mixer?

a)

It filters impurities from water.

b)

It controls the water flow rate.

c)

It maintains the required temperature by expanding and contracting.

d)

It adds minerals to the water.

10.

What is the purpose of a twin impellor booster pump in a plumbing system?

a)

To decrease water pressure

b)

To increase pressure for both hot and cold feeds

c)

To filter water impurities

d)

To heat the water

11.

How should a twin impellor booster pump be installed to reduce noise?

a)

Mounted on metal brackets

b)

Fitted with a flexible connector and mounted on rubber pads

c)

Placed directly on the floor

d)

Suspended from the ceiling

12.

What is the function of connecting a cylinder via an Essex flange?

a)

To increase water temperature

b)

To avoid any ingress of air

c)

To reduce water flow

d)

To filter the water

13.

What does connecting a cylinder via an angled hot water distribution pipe allow?

a)

Water to cool down

b)

Air from the cylinder to migrate up to the vent pipe

c)

Water to bypass the shower feed

d)

Water to circulate faster

14.

Where should a single impellor booster pump be used in a plumbing system?

a)

Before the mixer valve

b)

After the mixer valve

c)

At the water source

d)

At the shower head

15.

What is a negative head in plumbing?

a)

Pumping water to a level below the existing CWSC

b)

Pumping water to a level above the existing CWSC

c)

Pumping water at the same level as the existing CWSC

d)

Pumping water without any head

16.

What is a positive head in plumbing?

a)

Pumping water to a level above the existing CWSC

b)

Pumping water to a level below the existing CWSC

c)

Pumping water at the same level as the existing CWSC

d)

Pumping water without any head

17.

What activates a positive head pump?

a)

A manual switch

b)

A magnetic flow switch

c)

A pressure valve

d)

A temperature sensor

18.

What happens if the flowrate is not sufficient in a positive head pump?

a)

The pump will overheat

b)

The switch is not made

c)

The pump will reverse

d)

The pump will shut down

19.

What is a positive head shower operated by?

a)

A flow switch under natural flow of water

b)

An electric pump

c)

A manual valve

d)

A pressure sensor

20.

What is another name for a negative head pump?

a)

Centrifugal pump

b)

Positive head pump

c)

Submersible pump

d)

Diaphragm pump

21.

At what height does a negative head start below the CWSC?

a)

600mm

b)

500mm

c)

700mm

d)

800mm

22.

What type of valve does the outlet of a negative head pump have?

a)

Non-return valve

b)

Ball valve

c)

Gate valve

d)

Butterfly valve

23.

What activates a negative head pump?

a)

Magnetic flow switch

b)

Manual switch

c)

Pressure sensor

d)

Temperature sensor

24.

What is a key feature of negative head showers?

a)

Operated by a flow switch under a 'charge'

b)

Operated by a manual valve

c)

Operated by a pressure sensor

d)

Operated by a temperature gauge

25.

What force does a negative head pump use to move water to a higher level?

a)

Gravitational force

b)

Centrifugal force

c)

Magnetic force

d)

Electrical force

26.

What feature does an instantaneous electric shower incorporate to prevent water flow when electrics are on?

a)

High-pressure valve

b)

Low-pressure heating element cut-off solenoid

c)

Manual switch

d)

Automatic timer

27.

How is the shower protected in an instantaneous electric shower system?

a)

Single-pole switch

b)

Double-pole pull cord isolator

c)

Circuit breaker

d)

Fuse

28.

What is the purpose of a double-pole isolating switch in the wiring of electric showers?

a)

To control water temperature

b)

To isolate the electrical supply

c)

To regulate water pressure

d)

To enhance water flow

29.

What type of water heater is used for showers in an unbalanced feed system?

a)

Combination boiler or instantaneous water heater

b)

Solar water heater

c)

Electric immersion heater

d)

Gas-fired water heater

30.

What is required to manage pressure in an unbalanced feed shower system?

a)

A pressure compensating shower valve

b)

A water softener

c)

A temperature regulator

d)

A flow restrictor