cold water ph23

Total questions: 30

Worksheet time: 16mins

Name
Class
Date
1.

How often should cold water storage cisterns be checked and cleaned?

a)

Every month

b)

Every six months

c)

Every year

d)

Every two years

2.

How should water treatment equipment be maintained?

a)

Cleaned and cleared of scale and sediment build-up

b)

Checked in accordance with the manufacturers' literature

c)

Both A and B

d)

None of the above

3.

What should be checked when commissioning a pump?

a)

Pump inlet filter

b)

Valves

c)

Pipework for leaks

d)

All of the above

4.

How should accumulators be checked?

a)

By checking the vessel's pressure with a gauge

b)

By inspecting for leaks

c)

By checking for water damage

d)

By checking the flow rates

5.

What should be checked during a visual inspection of pipework?

a)

Sagging

b)

Corrosion

c)

Water hammer

d)

All of the above

6.

How often should TMVs be checked and cleaned?

a)

Every month

b)

Every six months

c)

Every year

d)

Every two years

7.

How can the cold water supply pressure to a property be identified?

a)

By contacting the local council or using a weir gauge at the kitchen sink

b)

By contacting the local council or using a pressure gauge at the supply to the FOV

c)

By contacting the water undertaker or using a pressure gauge at the cistern-fed outlets

d)

By contacting the water undertaker or using a pressure gauge at the kitchen sink

8.

Which formula can be used to determine flow rates through a pipe?

a)

Q = Av

b)

Q = A-v

c)

Q = m/s

d)

Q = V2

9.

According to guidance, all pipes and joints of a cold water system should be designed for a service life of:

a)

25 years at a temperature of 20C and a design pressure of 15 bar

b)

50 years at a temperature of 20C and a design pressure of 10 bar

c)

25 years at a temperature of 25C and a design pressure of 10 bar

d)

50 years at a temperature of 25C and a design pressure of 5 bar

10.

What is the recommended storage capacity of a CWSC supplying cold and hot water to a house?

a)

100 litres minimum

b)

150 litres minimum

c)

230 litres minimum

d)

350 litres minimum

11.

What is the recommended flow velocity of cold water within pipework?

a)

Between 0.25m/s and 1.5m/s

b)

Between 0.5m/s and 2m/s

c)

As close as practically possible to 2.5m/s

d)

As close as practically possible to 3.5m/s

12.

Which of the following factors would not directly affect the pressure and flow rates of pipework?

a)

Pipe diameter

b)

Pipe material

c)

Number of bends

d)

pH level of the water supply

13.

What should be fitted to the water supply feeding an accumulator to prevent the latter becoming damaged?

a)

Strainer, check valve and pressure reducing valve

b)

Strainer, check valve and gauge

c)

Check valve, pressure relief valve and gauge

d)

Check valve, water softener and regulating valve

14.

If the mains pressure to an accumulator is 3 bar, then what would be the most suitable air charge pressure within the vessel?

a)

3 bar

b)

2.5 bar

c)

1.5 bar

d)

0.5 bar

15.

A boosted cold water system is fitted with a break cistern at low level and a storage cistern at high level. The pump seems to have seized after 'running dry' for some time. What control component within the system is most likely to have failed and allowed this to happen?

a)

Float operated valve within the storage cistern

b)

Float operated level shut-off switch within the storage cistern

c)

Float operated valve within the break cistern

d)

Float operated low level shut-off switch within the break cistern

16.

A CWSC is overflowing during off-peak periods. What is the most likely cause?

a)

Blocked distribution pipe outlet

b)

Faulty level switch

c)

Split washer within FOV

d)

Pressure reducing valve set too high

17.

A sentinel outlet may be described as:

a)

a tap at the mid-position within a system

b)

the taps at the furthest and closest locations to the supply

c)

the taps at the highest and lowest points

d)

A tap outlet which is operated the least frequently

18.

What piece of test equipment is most suitable to check the run current of a boost cold water pump during maintenance or fault-finding activities?

a)

Voltmeter

b)

Multi-meter

c)

Low resistance Ohmmeter

d)

Clip-on Ammeter

19.

Why is it important to check the available incoming pressure when selecting a water supply system?

a)

To determine the cost of water supply installation

b)

To estimate the water consumption rate

c)

To ascertain the minimum available pressure during peak demand

d)

To calculate the volume of water storage required

20.

How can you determine the head of pressure in a cistern-fed water supply system?

a)

By measuring the distance from the base of the cistern to the outlet

b)

By analyzing water quality tests

c)

By checking the water meter reading

d)

By contacting the water undertaker

21.

What is a system used to estimate the likely demand for water supply based on?

a)

Gallons per minute (GPM)

b)

Cubic meters per second (m³/s)

c)

Loading Units (LU)

d)

Liters per hour (L/hr)

22.

Why is it important to consider the number and position of appliances when assessing water demand?

a)

To determine the color of the appliances

b)

To calculate the energy consumption of the appliances

c)

To estimate how often appliances will be used

d)

To identify the brand of appliances

23.

In a situation where there are more outlets and appliances on an installation, what tends to happen regarding their usage?

a)

More appliances are used simultaneously

b)

Fewer appliances are used simultaneously

c)

Usage remains the same regardless of the number of appliances

d)

The number of appliances has no impact on usage

24.

Which type of flow is promoted by smooth pipe surfaces, as opposed to turbulent flow?

a)

Subsonic flow

b)

Supersonic flow

c)

Laminar flow

d)

Oscillatory flow

25.

Compared to copper pipes, why does plastic pipe typically have a slightly better flow rate?

a)

Plastic pipe has a rougher internal bore.

b)

Plastic pipe is more prone to corrosion.

c)

Plastic pipe has a smoother internal bore.

d)

Plastic pipe is more rigid.

26.

In the equation Q = A * v, what does "Q" represent?

a)

Pipe diameter

b)

Flow rate

c)

Pipe length

d)

Velocity

27.

If the velocity of water in a pipe decreases, what typically happens to the flow rate?

a)

The flow rate increases.

b)

The flow rate remains constant.

c)

The flow rate decreases.

d)

The flow rate becomes zero.

28.

Fluid category 1 represents:

a)

a serious health risk

b)

a significant health risk

c)

a slight health risk

d)

no health risk

29.

What is the maximum depth at which a water main service pipe should be laid at?

a)

750mm

b)

1,250mm

c)

1,350mm

d)

1,750mm

30.

In an indirect boosted cold water system, what is the name of the low level cistern which is filled by the cold water main?

a)

Feed and expansion cistern

b)

Cold water storage cistern

c)

Spill cistern

d)

Break cistern