NCCER Electrical 2 Module 10

Total questions: 22

Worksheet time: 11mins

Name
Class
Date
1.

Overloads are often caused by _____.

a)

wires crossing

b)

motors starting

c)

a wire touching a metal frame

d)

a bare conductor contacting a metal tool

2.

Which of the following is TRUE regarding overload current?

a)

Overload current is confined to normal conductive paths.

b)

An overload is the same as a short circuit.

c)

An overload is an unintended current path.

d)

Protective devices must respond to all overloads.

3.

The requirements for overcurrent protection can be found in _____.

a)

NEC Article 240

b)

NEC Article 344

c)

NEC Article 440

d)

NEC Article 517

4.

Circuit breakers and fuses operate in a similar manner as a boiler's _____.

a)

expansion tank

b)

pressure relief valve

c)

heat exchanger

d)

burner

5.

Which of the following is TRUE with regard to circuit breakers?

a)

The interrupting capacity is based on the system load.

b)

The interrupting capacity is the same for each voltage level.

c)

The interrupting capacity is based on its rated voltage.

d)

The interrupting capacity is the same for each frequency.

6.

The frame size of a 20A circuit breaker is _____.

a)

20A

b)

50A

c)

75A

d)

100A

7.

The interrupting rating of an FH-type circuit breaker is _____.

a)

5,000A

b)

10,000A

c)

30,000A

d)

65,000A

8.

Circuits in which the breaker must be highly sensitive to amperage changes should use a(n) _____.

a)

non-automatic circuit breaker

b)

ambient-compensating circuit breaker

c)

standard magnetic breaker

d)

oil circuit breaker

9.

A device that trips when a fault current to ground is 6mA or more is designated by UL as _____.

a)

Class A

b)

Class B

c)

Class H

d)

Class R

10.

The heart is likely to stop when exposed to a current above _____.

a)

5mA

b)

30mA

c)

100mA

d)

200mA

11.

Which of the following is TRUE regarding a dual-element fuse?

a)

It is a single-use only device.

b)

It cannot be used in circuits subject to temporary overloads.

c)

It contains a fuse link connected in series with an overload element.

d)

It should be oversized to prevent nuisance trips.

12.

Type S fuses are available in sizes up to _____.

a)

30A

b)

60A

c)

100A

d)

225A

13.

Which of the following types of drawings helps when sizing fuses for a given application?

a)

Single-line schematic

b)

Large-scale detail

c)

Building elevation drawing

d)

Floor plan

14.

Cartridge fuses used for branch circuit protection must be marked with the ampere rating, interrupting rating (if other than 10,000A), and the _____.

a)

date manufactured

b)

dimensions

c)

expiration

d)

voltage rating

15.

The time-current relationship for a number of overcurrent devices connected in series is
known as _____.

a)

switching

b)

looping

c)

stringing

d)

coordination

16.

Worn motor bearings are most likely to result in a

_____.

a)

temporary overload

b)

sustained overload

c)

short circuit

d)

ground fault

17.

Where in the NEC® would you find information on

circuit breaker applications?

a)

NEC Section 240.85

b)

NEC Section 250.4(A)(1)

c)

NEC Section 310.15

d)

NEC Section 340.12

18.

A 250A fuse has a frame size of _____.

a)

250A

b)

300A

c)

350A

d)

400A

19.

At 300% of its rated current, a circuit breaker rated

at 600V must trip within _____.

a)

7 milliseconds

b)

0.7 seconds

c)

7 seconds

d)

70 seconds

20.

An acceptable fuse combination is a _____.

a)

30A fuse used to protect a non-motor 20A

circuits

b)

10A fuse used to protect a non-motor 20A

circuit

c)

30A non-time-delay fuse used to protect a 15A

motor

d)

45A dual-element fuse used to protect a 15A

motor

21.

When sizing a non-time-delay fuse for a branch

circuit with no motor load, the fuse size must be at

least _____.

a)

125% of the continuous load plus 100% of the

non-continuous load

b)

150% of the continuous load

c)

100% of the continuous load plus 100% of the

non-continuous load

d)

200% of the non-continuous load

22.

Selective coordination is used in complex systems

in order to _____.

a)

shut down the whole system if a fault occurs in

a feeder

b)

ensure that the device nearest any load is faster

than all devices closer to the supply

c)

allow branch circuit faults to trip both feeder and

service overcurrent devices

d)

ensure that the main service fuses have the

shortest opening time for any branch or feeder

fault