wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Analytical Chemistry Quiz Test I

Total questions: 17

Worksheet time: 9mins

Name
Class
Date
1.

What is one method used to express accuracy in analytical chemistry?

a)

Standard deviation

b)

Signal-to-noise ratio

c)

Relative error

d)

Coefficient of variation

2.

Gross errors in analytical data are typically caused by____.

a)

Instrument malfunction

b)

Inaccurate calibration

c)

Incorrect calculations

d)

Human mistakes during measurement

3.

The estimation of glucose using Fehling’s solution is primarily based on____.

a)

Redox titration

b)

Acid-base titration

c)

Precipitation reaction

d)

Complexometric titration

4.

The reagent that commonly oxidizes glucose to gluconic acid during its estimation is______.

a)

Benedict's solution

b)

Fehling's solution

c)

Tollen's reagent

d)

Barfoed's reagent

5.

Thermogravimetric analysis (TGA) is based on____.

a)

Mass change

b)

Volume change

c)

Heat flow

d)

Conductivity

6.

The component used to measure heat flow in DSC is____.

a)

Thermocouple

b)

Balance

c)

Microscope

d)

Calorimeter

7.

Principle of colorimetry and spectrophotometry______.

a)

Conductivity

b)

Light absorption

c)

Mass change

d)

Volume change

8.

Unit of absorbance___.

a)

%T

b)

M

c)

AU

d)

g/mL

9.

Elution in column chromatography____.

a)

Packing column

b)

Washing impurities

c)

Separating components

d)

Analyzing components

10.

Solvent for non-polar compounds in TLC_______.

a)

Water

b)

Hexane

c)

Ethanol

d)

Acetic acid

11.

Which of the following methods is used to express precision in analytical data?

a)

Range

b)

Sensitivity

c)

Toxicity index

d)

Mean deviation

12.

In the Fehling’s solution method for glucose estimation, sulfuric acid is used to___

a)

Act as a reducing agent

b)

Stabilize the Fehling’s solution

c)

Provide an acidic environment for the reaction

d)

Precipitate the glucose

13.

Differential thermal analysis (DTA) measures___.

a)

Mass change

b)

Heat flow

c)

Volume change

d)

Conductivity

14.

The parameter NOT measured in DSC is___.

a)

Mass

b)

Enthalpy

c)

Heat capacity

d)

Phase transition

15.

Rf in chromatography_____.

a)

Relative fluidity

b)

Relative flow

c)

Retention factor

d)

Reaction factor

16.

Solvents in paper chromatography____.

a)

Water & ethanol

b)

Hexane & chloroform

c)

Ethanol & acetone

d)

Ethyl acetate and methanol

17.

What is the primary purpose of establishing safe limits for chemical exposure in the laboratory?

a)

To minimize waste generation

b)

To ensure efficient disposal methods

c)

To protect personnel from harmful effect

d)

To reduce laboratory expenses