WorksheetsPLC Quiz
Total questions: 48
Worksheet time: 24mins
PLC has replaced__________
Transistor
Computer
Relay Logic
Solenoid
Disadvantage of PLC is _________
Security
Documentation
Fixed program application
Pilot running
PLC stands for_______
Programmable Ladder Controller
Program Low Controller
Programmable Logic Controller
Programmable Logic Converter
If the I/O Count of PLC is between 32 to 128 then it is called as ___________.
Micro PLCs
Medium PLCs
Small PLCs
Large PLCs
Output modules are available in various switching and _______configurations.
AC
DC
Relay
Transistor
The devices connected to PLC for sending status information are called _______field devices.
Programmer and monitoring
Memory
Output
Input
Hand held terminals is an example for___________.
CPU
Input Module
output Module
Programmer and monitoring
In PLC the user program is stored in ________ memory.
ROM
PROM
EPROM
EEPROM
Input modules provide an interface between ______________and_____________.
Input connections and the CPU
Field equipment and the CPU
Output modules and field devices
The CPU and output modules
PLC I/O systems provides an interface between __________ and ___________.
Input devices and the CPU
Field equipment and the CPU
Output modules and field devices
Input modules and output modules
Electrical isolation is provided so that there is no physical electrical connection between the CPU and output field devices. This isolation is usually accomplished by____________
Power supply
Rectifier
Opto coupler
Holding Register
1K of memory is equal to ________
1000 bits
1000 words
1024 bits
1024 words
Power signal that the output module switches to control field devices must be provided by__________
The CPU
The user
The master control relay
Relay
A _____ is usually mounted on one end of each rack, backplane, or chassis.
CPU
single power supply
memory card
I/O Card
The programming device must be connected ____________ to the controller
At all times
When entering a programme
When monitoring a programme
When entering or monitoring a programme
The basic difference between plc and relay control system is ___________
Different input and output voltage levels are used
Different types of output devices are used
Different types of input devices are used
One uses relay control logic & other uses programmed instructions
The abbreviations NO and NC represents the electrical state of switch contacts when_______________.
Power is applied
Power is not applied
The switch is actuated
The switch is not actuated
NC push button connected in hardware & NC contact in software then the coil connected to the NC contact will be ___________
ON
OFF
Short
Toggle
A limit switch is usually actuated by_________.
Hand
Pressure
Contact with an object
An electromagnet
A thermocouple ,when heated _______
Produces a small dc voltage
Increases its resistance value
Produces a small AC voltage
Decreases its resistance value
A________converts electrical pulses applied to it into discrete rotor movement
Tachometer
Solenoid
Stepper motor
Electronic magnetic flow meter
Digital I/O modules operate on___________
24V AC supply
24V DC supply
5V AC supply
12V DC supply
PNP type proximity sensor is compatible with __________ input module.
Sourcing
Sinking
AC
DC
NPN type proximity sensor is compatible with __________ input module
sourcing
sinking
AC
DC
Discrete input modules accept signals from field devices that are________
Analog type
Digital Type
Two-state Type
Digital or Two state type
A discrete input signal is considered valid if the signal is________
Is a two-state signal
Is successfully change from AC to DC through the bridge rectifier
For an AC signal, if it is between 80 & 132 VAC
If it is continous
Thumbwheels switches provide input to the PLC in _______ format
BCD
Binary
DECIMAL
Hexadecimal
Discrete output interface modules send signals to field devices that are__________
Digital devices
Analog devices
Two-state devices
Digital or Two state Device
Discrete output modules act as a _________ to control output field devices
Relay
Switch
Contactor
solenoid
Typical discrete output devices include_______
Servo Motor
Inductive proximity switches
Solenoids
LVDT
Changing signals like temperature control or the 4 to 20-milliamp-speed reference for a variable-frequency drive are called ______ signals
analog input
digital input
analog output
digital output
Suppose you need to select a module to interface AC or DC, two-state, ON/OFF, or OPEN/CLOSED incoming signals.which will you choose
analog input module
analog output module
discrete input module
combination of Analog and discrete input module
Suppose you need to select a module to inter face out going AC or DC,two state, ON/OFF, or OPEN/CLOSED outgoing signals.Which will you choose
discrete output module
analog output module
discrete input module
Analog input module
Suppose you need to select a module to interface a continuously changing incoming voltage or current signal.which will you choose
analog input module
analog output module
discrete input module
combination of Analog and discrete input module
A discrete input module which can be interfaced is ___________
push buttons
Horn
contactor
Pilot lamp
Volatile memory is__________
RAM
ROM
PROM
EEPROM
Nonvolatile memory is________
RAM
ROM
PROM
EEPROM
The processor in any PLC is designed to perform specific duties in a specific sequence and then continuously repeat the sequence.The operating cycle is called __________
Access time
Operating system
Scan Cycle
scan time
The scan consists of a series of sequential operations which include, Reading________, program execution, data output
connection
Input
Output
Tie point
If the input devices change its state while the processor is in program scan or output scan of the scan cycle then the plc will _____________
Immediately react to them
React during the next scan cycle
Response very slow
Does not react to them
If two NC contacts are connected in series that satisfies _______Gate logic
AND
NAND
OR
NOR
NC contact can be used to satisfy ________gate condition.
NOT
OR
AND
NOR
If two NO contacts are connected in series that satisfies _______Gate logic.
OR
NAND
NOR
AND
If two NC contacts are connected in parallel that satisfies _______Gate logic.
AND
NAND
OR
NOR
The logical OR function is similar to connecting two NO contacts in _____________
parallel
series
Direct reversal
Indirect reversal
Status of input devices are stored in ________ Register.
Output single
Input single
Output group
Input group
Each instruction on a ladder diagram has a reference number associated with it which is_________
Its instruction comment
Its position identifier on the ladder rung
a number referencing the instructions associated input status table bit addrress
the instructions input address
Holding register is also known as_______.
Input register
Output Register
Working Register
Group Register