3004 LO2 13 Electrical fittings & Safety , RCD, IP, Fuses

Total questions: 18

Worksheet time: 9mins

Name
Class
Date
1.

What are the two numbers on here called?

a)

IP rating

Safety rating

b)

IP address line

Connection address number

c)

IP network link

Main system link

d)

Power rating

I = Current

P = Power

2.

What is the first number?

a)

Protection against solids like dust and stones

b)

Protection against liquids like water

c)

Protection against over-current

d)

Protection against voltage spikes

3.

What is the second number?

a)

Protection against solids like dust and stones

b)

Protection against liquids like water

c)

Protection against over-current

d)

Protection against voltage spikes

4.

What is the correct number for strong water hose protection?

a)

First digit 6

b)

Second digit 6

c)

First digit 5

d)

Second digit 5

e)

First digit 4

5.

What is the difference between the plugs?

a)

New Zealand uses #1

Australia uses #2

b)

#1 is for 230V

#2 is for 400V

#3 is for DC Voltage

c)

#1 is 10A

#2 is 15A

#3 is 20A

d)

Plus #2 and #3 have a higher IP rating

6.

What is rating for #2?

a)

400V

b)

15A

c)

IP66

d)

10A

7.

What is rating for #3?

a)

1000V

b)

20A

c)

IP65

d)

15A

8.

What is rating for #1?

a)

1000V

b)

10A

c)

IP65

d)

15A

9.

What does the symbol on the right stand for?

a)

M.C.B.

b)

Isolator

c)

Switch

d)

RCD

10.

What does the symbol on the right stand for?

a)

M.C.B.

b)

Isolator

c)

Switch

d)

RCD

11.

What is the C for on the circuit breaker?

a)

Tripping curve

b)

RCD balanced current

c)

Current Max

d)

Current Min

12.

What does the symbol on the right stand for?

a)

M.C.B.

b)

Isolator

c)

Switch

d)

RCD

13.

What current imbalance would this detect in a home?

a)

3A

b)

0.3A

c)

0.03A

d)

0.003A

14.

What current imbalance would this detect in a hospital?

a)

30mA

b)

10mA

c)

3mA

d)

100mA

15.

What are these?

a)

Fire retardant fuses

b)

High current fuses

c)

High rupturing fuses

d)

Rewirable fuses

16.

What are these?

a)

Fire retardant fuses

b)

High current fuses

c)

High rupturing fuses

d)

Rewirable fuses

17.

How do we use these?

a)

Only for split level housing

b)

Only on gas stoves

c)

Not allowed anymore on new build houses, but can replace

d)

In bathrooms only

18.

Can we replace the wire on these?

a)

With ceramic agnimestons - Yes

b)

They are illegal - No

c)

With higher rated fuse wire - Yes

d)

With exact rated fuse wire - Yes