DEE40223 Low Voltage Distribution Topic 1

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

What is the definition of a switchboard according to Regulation 2?

a)

An assembly of switchgear with or without instruments

b)

A type of circuit breaker

c)

An assembly of local switches

d)

A device that generates electricity

2.

What must always equal the power going out to the loads in a switchboard?

a)

The insulation resistance

b)

The current rating of the switchboard

c)

The voltage of the switchboard

d)

The power going into the switchboard

3.

What is the minimum thickness of the enclosure structure for a switchboard?

a)

1.5mm

b)

2.0mm

c)

2.5mm

d)

3.0mm

4.

What degree of protection is required for the enclosure of a switchboard as per IEC 529?

a)

IP 40

b)

IP 41

c)

IP 20

d)

IP 30

5.

What is the purpose of anti-condensation heaters in a switchboard?

a)

To enhance insulation

b)

To prevent moisture accumulation

c)

To increase voltage

d)

To reduce power loss

6.

What is the required sensitivity for the residual current device protecting the heating system?

a)

10mA

b)

100mA

c)

30mA

d)

50mA

7.

What should be the degree of protection for exposed parts within the assemblies?

a)

IP 40

b)

IP 10

c)

IP 30

d)

IP 20

8.

What is the time value of the rated short-time withstand current for switchgear?

a)

3 seconds

b)

1 second

c)

0.5 seconds

d)

2 seconds

9.

What is the purpose of the rubber mat placed in front of every switchboard?

a)

To improve visibility

b)

To enhance aesthetics

c)

To prevent electric shock

d)

To provide insulation

10.

What is the minimum requirement for a person to access any part of the switchboard?

a)

Must be a supervisor

b)

Must be trained in first aid

c)

Must be a licensed electrician

d)

Must be a competent person

11.

What is the purpose of the notice displaying 'DILARANG MASUK'?

a)

To indicate a storage area

b)

To provide instructions

c)

To warn against unauthorized access

d)

To indicate a safe area

12.

What should be done if a switchboard is operating at high voltage?

a)

Ensure all conductors are earthed

b)

Use insulated tools only

c)

No special precautions needed

d)

Place conductors within reach

13.

What is the required action for the metallic frame of any instrument in a switchboard?

a)

It should be painted

b)

It should be earthed

c)

It should be insulated

d)

It should be removed

14.

What is the minimum thickness of electro galvanized sheet steel used in switchboard construction?

a)

2.5mm

b)

1mm

c)

1.5mm

d)

2mm

15.

What is the requirement for a switchboard manufacturer regarding registration?

a)

Must have a physical store

b)

Must have a business license

c)

Must hold a valid Certificate of Registration

d)

Must be registered with the local authority

16.

What should be done if a switchboard is located in a storage area?

a)

Ensure it is fenced or enclosed

b)

Relocate the storage

c)

Leave it as is

d)

Remove the switchboard

17.

What is the required action for shutters covering busbars?

a)

They should be marked 'BUSBAR'

b)

They should be painted

c)

They should be insulated

d)

They should be removed

18.

What is the required action for the short circuit protection device inside each functional unit?

a)

It should be tested regularly

b)

It should be connected to the outgoing supply

c)

It should be connected to the incoming supply

d)

It should be left unconnected

19.

What is the required action for the construction of switchboards regarding corrosion?

a)

No protection needed

b)

Adequate protection against corrosion

c)

Only paint is required

d)

Use of plastic materials

20.

What is the required action for the arrangement of switchboard parts?

a)

They should be removable

b)

They should be accessible

c)

They should be hidden

d)

They should be decorative