Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

PEC Sample Quiz 1

Total questions: 15

Worksheet time: 5mins

Name
Class
Date
1.

The main purpose of the Philippine Electrical Code (PEC) is:

a)

To maximize efficiency of electrical systems

b)

To safeguard persons and property from electrical hazards

c)

To reduce construction costs

d)

To improve power quality

2.

Which of the following is NOT included in the scope of PEC?

a)

Public and private buildings

b)

Industrial plants

c)

Energy management and power quality issues

d)

Watercraft

3.

Which of the following is NOT an electrical plan requirement?

a)

Load schedule

b)

One-line diagram

c)

Short-circuit study

d)

Owner’s tax ID number

4.

A conductor in continuous duty application for motors is derated by applying:

a)

100% FLC

b)

115% FLC

c)

125% FLC

d)

150% FLC

5.

A conduit run has bends of 90°, 90°, 45°, and 45°. According to PEC:

a)

Permitted

b)

Not permitted

c)

Requires approval of PRC

d)

Requires oversized conductor

6.

In interpretation disputes of PEC, the final decision rests with:

a)

The contractor

b)

The PEC Part 1 Committee

c)

The Board of Electrical Engineering

d)

The OBO

7.

“Current-limiting circuit breakers” are designed to:

a)

Reduce resistance

b)

Prevent short-circuit current from reaching its peak value

c)

Increase voltage stability

d)

Improve insulation strength

8.

A PVC conduit larger than metric designator 155 (trade size 6) is:

a)

Allowed only underground

b)

Not permitted

c)

Allowed only with copper conductors

d)

Permitted in industrial plants

9.

Which PEC rule classification deals with motor nameplate markings?

a)

Installation rules

b)

Manufacturing rules

c)

Wiring design rules

d)

Explanatory rules

10.

The ampacity of conductors depends on:

a)

Insulation type

b)

Ambient temperature

c)

Conductor cross-sectional area

d)

All of the above

11.

PVC conduit is NOT permitted in:

a)

Concealed installations

b)

Wet locations

c)

Hazardous classified locations

d)

Underground

12.

A rigid metal conduit (RMC) is defined as:

a)

A non-metallic raceway

b)

A threadable metallic raceway

c)

A flexible cable

d)

A grounding conductor

13.

The number of conductors in a conduit is limited by:

a)

Voltage rating

b)

Temperature rating

c)

Percent fill of cross-sectional area

d)

Length of conduit

14.

A conductor marked “THHW” means:

a)

Thermoplastic, heat- and water-resistant

b)

Thermoset, heavy-duty, waterproof

c)

High-voltage wire only

d)

Thin heat welding wire

15.

The minimum requirement before starting any electrical work is:

a)

Contract approval

b)

Electrical Permit from OBO

c)

Materials procurement

d)

Fire safety inspection