Full Sizing Quiz 2015 - Missed Questions

Total questions: 16

Worksheet time: 8mins

Name
Class
Date
1.
48. Steel pipe for water and DWV shall be supported vertically and horizontally every __________ for 1 inch and larger. Choose all that apply
a)
a. 6 feet
b)
b. 12 feet
c)
c. every other floor
d)
d. 10 feet
2.
50. Steel pipe for water and DWV 3/4" and smaller, shall be supported vertically and horizontally every _____ feet. Choose all that apply.
a)
a. not to exceed 25 feet
b)
b. 10 feet
c)
c. 12 feet
d)
d. every other floor
3.
21. The maximum trap arm length for a 11/2" trap is _____________.
a)
a. 32 inches
b)
b. 2 feet 6 inch
c)
c. 42 inches
d)
d. 3 feet
4.
5. From Table 501.1, the first hour rating for a domestic water heater that serves 1 to 1.5 bathroom(s) with 2 bedrooms is _______ Gallons.
a)
a. 38
b)

b. 42

c)

c. 54

d)

d. 67

5.
20. The maximum trap arm length for a 11/4" trap is _____________.
a)
a. 32 inches
b)
b. 2 feet 6 inch
c)
c. 36 inches
d)
d. 3 feet 6 inches
6.
36. Indirect drains for bar and fountain sinks shall not exceed _______ feet.
a)
a. 3
b)
b. 5
c)
c. 10
d)
d. 15
7.
47. Cast iron hubless pipe shall be supported horizontally ________ . Choose all that apply.
a)
a. every other joint
b)
b. if over 4 feet, every joint
c)
c. 10 feet
d)
d. within 18" of each joint
8.
15. The maximum fixture unit load for a 11/4" P-Trap is ________ Units.
a)
a. 1
b)
b. 2
c)
c. 3
d)
d. 4
9.
16. The maximum fixture unit load for a 11/2" P-Trap is ________ Units.
a)
a. 1
b)
b. 2
c)
c. 3
d)
d. 4
10.
25. A 4" trap arm is serving a 3.5 GPF water closet, the maximum length shall not exceed ___________.
a)
a. 10 feet
b)
b. 6 feet 6 inches
c)
c. 6 feet
d)
d. 8 feet
11.
42. Nail plates shall be used when the pipe is ___________ inch(s) from exposed framing.
a)
a. 1/2
b)
b. 1
c)
c. 11/2
d)
d. 3
12.
6. From Table 501.1, the first hour rating for a domestic water heater that serves 1 to 1.5 bathroom(s) with 3 bedrooms is _______ Gallons.
a)
a. 38
b)

b. 42

c)

c. 54

d)

d. 64

13.
22. The maximum trap arm length for a 2" trap is _____________.
a)
a. 52 inches
b)
b. 4 feet 6 inch
c)
c. 42 inches
d)
d. 5 feet
14.
26. The minimum length of a 11/4" trap arm is _______ inches .
a)
a. 2
b)
b. 21/2
c)
c. 3
d)
d. 4
15.
34. Indirect waste pipes over _______ feet shall be trapped.
a)
a. 3
b)
b. 5
c)
c. 8
d)
d. 10
16.
35. Indirect waste pipes shall not exceed _______ feet.
a)
a. 5
b)
b. 10
c)
c. 15
d)
d. 20