wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

209 Carry out second fixing operations

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

Which Regulations reduce exposure to hazardous substances?

a)

PPE

b)

COSHH

c)

PUWER

d)

RIDDOR

2.

What is the name of the section of timber that runs vertical in the middle of a panelled door?

a)

Stile

b)

Jamb

c)

Muntin

d)

Mullion

3.

What is a typical standard internal fire door size?

a)

1981mm x 762mm x 35mm

b)

1981mm x 762mm x 44mm

c)

2032mm x 762mm x 35mm

d)

2032mm x 762mm x 44mm

4.

Which colour indicates a fire resistance of up to 60 minutes?

a)

Blue

b)

Black

c)

Brown

d)

Yellow

5.

What is the name of the component marked X?

a)

Plinth Blocks

b)

Lintel

c)

Cornice

d)

Sill

6.

What is the name of the moulding profile shown below?

a)

Pencil round

b)

Splayed

c)

Ogee

d)

Torus

7.

Which joint should be used on an internal corner for skirting?

a)

Butt

b)

Mitre

c)

Scribe

d)

Heading

8.

Which joint should be used on an external corner for skirting?

a)

Heading

b)

Scribe

c)

Mitre

d)

Butt

9.

A mortice and tenon joint is required from finished section of timber 94mm x 45mm. What size mortice should be set out?

a)

10mm

b)

15mm

c)

30mm

d)

31mm

10.

What type of housing joint is shown below?

a)

Double stopped

b)

Dovetailed

c)

Through

d)

Stopped

11.

The width of a tenon should not exceed how many times the thickness of the tenon?

a)

2

b)

3

c)

4

d)

5

12.

What joint would be used to lengthen a piece of timber?

a)

Scarf

b)

Housing

c)

Dovetail

d)

Mortice and tenon

13.

What do the letters RSJ stand for in relation to encasing services?

a)

Related support joint

b)

Rolled steel joist

c)

Round system joist

d)

Relevant scarf joint

14.

What is the maximum centres noggin should be fixed?

a)

200mm

b)

400mm

c)

600mm

d)

1200mm

15.

Calculate the total amount of architrave required to fit around two sets of door linings. Height of architrave required 2.1m, width required 900mm.

a)

5.1m

b)

10.2m

c)

20.4m

d)

40.8m

16.

A wall measuring 5.0m by 3.0m requires cladding with sheet materials. How many sheets of 2.4m by 1.2m boarding will be required to cover the wall?

a)

4 sheets

b)

5 sheets

c)

6 sheets

d)

7 sheets

17.

What is the name of the component marked X in the view of a timber frame for encasing services shown below?

a)

Studs

b)

Noggins

c)

Top plate

d)

Sole plate

18.

When setting out a timber frame for encasing services, what centres are they usually set?

a)

300mm to 400mm

b)

400mm to 600mm

c)

450mm to 800mm

d)

500mm to 900mm

19.

For what purpose is an intumescent seal or strip used?

a)

To insulate pipework in a soil stack

b)

To identify fire door rating colours

c)

To reduce the spread of smoke and heat

d)

To position and locate hinges

20.

What is the name of the component shown in the diagram below?

a)

Corbel

b)

Cornice

c)

Picture rail

d)

Plinth block