Electrical Code Quiz 1

Total questions: 22

Worksheet time: 11mins

Name
Class
Date
1.

What is the primary purpose of the Code mentioned in the document?

a)

To provide design specifications

b)

To serve as an instruction manual for untrained persons

c)

To safeguard persons and property from electrical hazards

d)

To enhance the efficiency of electrical installations

2.

Which of the following is NOT covered by the Code according to the document?

a)

Public and private premises

b)

Installations in ships

c)

Mobile homes

d)

Floating buildings

3.

How many chapters does the NEC organize the Code into?

a)

Five

b)

Seven

c)

Nine

d)

Eleven

4.

What is the role of the Authority Having Jurisdiction (AHJ) as outlined in the document?

a)

Designing electrical systems

b)

Interpreting code rules

c)

Installing electrical equipment

d)

Manufacturing electrical components

5.

What is required for the approval of electrical equipment according to the document?

a)

Approval by any electrician

b)

Approval by the authority having jurisdiction (AHJ)

c)

Approval by the equipment manufacturer

d)

Approval by the facility manager

6.

What should be considered when using dissimilar metals in electrical connections?

a)

They should be mixed freely

b)

They should be identified for the material of the conductor

c)

They should be used without any identification

d)

They should be avoided at all costs

7.

What is the minimum working space access required for electrical equipment?

a)

500 mm wide and 1.5 m high

b)

610 mm wide and 2.0 m high

c)

700 mm wide and 2.5 m high

d)

800 mm wide and 3.0 m high

8.

What is the minimum width of a clear work space required where cables are located on both sides?

a)

750 mm (2½ ft)

b)

900 mm (3 ft)

c)

650 mm (2 ft)

d)

1000 mm (3½ ft)

9.

What is the purpose of bonding all non-current-carrying metal parts of electrical equipment?

a)

To increase electrical resistance

b)

To ensure proper insulation

c)

To prevent electrical shock

d)

To enhance signal transmission

10.

What is the minimum size for rectangular access openings to manholes?

a)

550 mm x 450 mm

b)

700 mm x 600 mm

c)

650 mm x 550 mm

d)

600 mm x 500 mm

11.

What type of protection does a combination-type AFCI provide?

a)

Overvoltage protection

b)

Short circuit protection

c)

Arc-fault protection

d)

Ground fault protection

12.

What is the nominal voltage limitation for branch circuits according to the document?

a)

It must not exceed the values permitted by 210.6(A) through (D).

b)

It must not exceed 100 volts.

c)

It must not exceed 200 volts.

d)

It must not exceed 300 volts.

13.

What type of protection does a Class A GFCI provide according to the document?

a)

Overload protection

b)

Ground-fault circuit-interrupter protection

c)

Short-circuit protection

d)

Thermal protection

14.

How many sets of 3-wire feeders are permitted to utilize a common neutral?

a)

Up to two sets

b)

Up to three sets

c)

Up to four sets

d)

Up to five sets

15.

What is the minimum size for overhead individual conductors for spans up to 15 m (50 ft) in length?

a)

12 AWG copper

b)

10 AWG copper

c)

8 AWG aluminum

d)

6 AWG aluminum

16.

What is the minimum height above finished grade for the point of attachment of overhead service conductors?

a)

1.0 m (3 ft)

b)

2.0 m (6 ft)

c)

3.0 m (10 ft)

d)

4.0 m (13 ft)

17.

How many sets of service-entrance conductors can a single service drop supply?

a)

One set

b)

Two sets

c)

Three sets

d)

Four sets

18.

Where should the service disconnecting means be installed?

a)

In the basement

b)

At a readily accessible location

c)

On the roof

d)

In the attic

19.

What is the minimum thickness required for a steel plate or bushing used to protect cables or raceways from penetration by screws or nails?

a)

1.0 mm

b)

1.6 mm

c)

2.0 mm

d)

2.5 mm

20.

According to the document, where can conductors described in 310.4 be used?

a)

Only in dry locations

b)

Only in wet locations

c)

In any of the wiring methods covered in Chapter 3

d)

Only in direct burial

21.

What type of cable is covered under article 330?

a)

Nonmetallic-sheathed cable

b)

Underground feeder cable

c)

Metal-clad cable

d)

Power and control tray cable

22.

For what type of locations is the underground feeder and branch-circuit cable, Type UF, suitable?

a)

Only dry locations

b)

Only wet locations

c)

Wet, dry, or corrosive locations

d)

Only corrosive locations