Residential wiring - Hardware and Material

Total questions: 30

Worksheet time: 15mins

Name
Class
Date
1.

OSHA requires special training and certification before an electrician can use powder-actuated fastening systems.

a)

True

b)

False

2.

If a piece of electrical equipment has a nationally recognized testing laboratory __________ on it, it means that the item has met specific standards and is suitable for its intended purpose.

a)

marking

b)

label

c)

sticker

d)

Either a or b.

3.

The ____________ develops electrical equipment standards that all member manufacturers follow when designing and producing electrical equipment.

a)

NEMA

b)

NFPA

c)

ANSI

d)

NRTL

4.

The NEC requires that a junction box be accessible after installation; therefore, it cannot be buried in a wall or ceiling.

a)

True

b)

False

5.

The ____________ is the system used to size conductors in residential wiring.

a)

international wire sizing charts

b)

American Wire Gauge (AWG)

c)

NEC® wire table

6.

Eye protection is not always required when you are driving nails.

a)

True

b)

False

7.

The article in the NEC® that covers nonmetallic-sheathed cable is Article (a)   .

Choose from the below words

90

220

334

8.

The most common sizes of machine screws used in residential wiring are 6-32, 10-32, and 12-32.

a)

True

b)

False

9.

When ganging metal device boxes together, a (a)   is needed to tighten the screws that hold the boxes together.

Choose from the below words

screwdriver

pair of pliers

nut driver

10.

The (a)   is a scale of specified diameters and cross-sections for wire sizing and is the standard wire sizing scale for the United States. (Objective 2-6)

Choose from the below words

American Wire Gauge

metric system

United States measuring system

none of the choices

11.

An accidental connection between a "hot" ungrounded conductor and a grounded piece of equipment or the grounded conductor is called a(n) (a)   .

Choose from the below words

open circuit

grounding conductor

ground fault

complete circuit

12.

Drive studs are installed using a (a)   .

Choose from the below words

hammer

powder-actuated fastening system

a screwdriver

13.

It is the (a)   who has the job of approving the electrical materials used for a residential electrical installation.

Choose from the below words

electrician

foreman

architect

authority having jurisdiction

14.

When nonmetallic device boxes that are two-gang or more are used, the installed Type NM cable must be supported no more than (a)   inches from the box.

Choose from the below words

6”

8”

12”

3 ft

15.

When using aluminum conductors, (a)   size conductor must be used to carry the same amount of current as a copper conductor.

Choose from the below words
a. a smaller

b. the same

c. same or larger
 larger
16.

The (a)   -colored circuit conductor is used as the grounded conductor and returns current from the load back to the source.

Choose from the below words

black

white

red

green

17.

7. Type ____________ cable is used for underground installations of branch and feeder circuits.

a)

UF (Underground Feeder)

b)

NM (Non-Metallic)

c)

THHN (Thermoplastic High Heat-Resistant Nylon-Coated)

d)

MC (Metal-Clad)

18.

8. Type ____________ cable is used for underground service entrance installations.

a)

USE (Underground Service Entrance)

b)

NM (Nonmetallic Sheathed)

c)

THHN (Thermoplastic High Heat-resistant Nylon-coated)

d)

AC (Armored Cable)

19.

The NEC® requires rigid metal conduit to be supported within _______ feet of each box and then no more than every _______ feet thereafter.

a)

3,8

b)

5, 10

c)

2, 10

d)

3, 10

20.

10. The ungrounded "hot" conductor is terminated to the ____________-colored terminal on a receptacle.

a)

brass

b)

silver

c)

green

d)

black

21.

A switch used on 240-volt circuits to control a load from one location is called a ________________ switch.

a)

single-pole

b)

double-pole

c)

occupancy

d)

combination

22.

Which of the following switches has "ON/OFF" marked on the switch handle?

a)

three-way

b)

double-pole

c)

four-way

d)

none of the choices

23.

______________ are the most commonly used type of overcurrent protection device in residential wiring.

a)

Circuit breakers

b)

Edison base plug fuses

c)

Plug fuses

d)

Cartridge fuses

24.

(a)   fuses are considered non-tamperable and are used in new installations requiring fuses.

Choose from the below words

Edison base plug

Type S plug

Cartridge

Plug

25.

A part of an electrical box that is designed to be removed so that a cable or raceway can be connected to the box is called a (a)   .

Choose from the below words

knockout

mounting bracket

cable clamp

plaster ear

26.

When two or more electrical device boxes are joined together to hold more than one device, it is called _____________________.

a)

ganging

b)

splicing

c)

looping

d)

branching

27.

17. All _________________ boxes must be accessible after installation.

a)

junction

b)

storage

c)

safety

d)

supply

28.

In residential wiring, the NEC® requires a ______________-amp circuit breaker or fuse to be used with 12 AWG copper conductors.

a)

20

b)

15

c)

25

d)

30

29.

A ____________________ is an overcurrent device that opens a circuit when a fusible link melts due to the extreme heat caused by an overcurrent.

a)

fuse

b)

circuit breaker

c)

transformer

d)

relay

30.

20. (a)   fuses cannot be used in new installations.

Choose from the below words

Edison base plug

Type S plug

Cartridge

Plug