EIM Reviewer Part 3

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

The selection requirements for circuit breaker are

a)

Ampacity, Rated Power and Rated Voltage

b)

Ampere Frame, Ampacity and Kilo Ampere Interrupting Capacity

c)

Kilo Ampere Interrupting Capacity, Ampere Trip and Ampere Frame

d)

Ampere Frame, Full Load Current and Rated Voltage

2.

The size of circuit breaker to be used in 40A motor full load current is

a)

Not less than 125% of the full load

b)

More than 115% of the full load

c)

Less than 50AT

d)

Equal to 100AT

3.

What is the commonly used conduit in service entrance?

a)

PVC

b)

EMT

c)

RSC/IMC

d)

Flex Conduit

4.

Why is it necessary to use torque wrench in tightening bolted joints of copper bus ducts and bus ways?

a)

To prevent heating of joints

b)

To reduce the resistance in the joints

c)

To make sure the joints are well tightened

d)

To give allowance for thermal expansion

5.

When tightening a terminal screw connection, the end of the wire should pass around the screw in the same direction as the screw is turned so that

a)

The wire will act as a locknut

b)

Any pull on the wire will tighten the screw

c)

The wire will not turn off

d)

The screw can be remove easily

6.

Most of the required electrical parameters apply to an incandescent bulb are...

a)

Rated power and rated voltage

b)

Rated resistance and rated current

c)

Rated current and rated voltage

d)

Rated power and rated current

7.

These are sheet metal troughs with hinged or removable covers for housing and protecting electrical wires and cables and in which conductors are laid in place these are installed. They are called

a)

Bus ways

b)

Wire ways

c)

Cable ducts

d)

Cable trays

8.

A technical term for type THW wires used mostly in industrial wirings is

a)

PVC Insulated Heat Resistance

b)

Moisture and Heat Resistance

c)

Thermoplastic Poly Vinyl Chloride

d)

Plastic Covering

9.

It is the connection between the grounded circuit conductor and the equipment grounding conductor at the service.

a)

Bonding jumper, main

b)

Bonding jumper, equipment

c)

Bonding Jumper

d)

Grounding Electrode Conductor

10.

What is the ampacity of #8 (5.5) sq. mm. THW wire?

a)

35 amperes

b)

20 amperes

c)

25 amperes

d)

50 amperes

11.

Commonly used adhesive materials for joining of PVC conduit

a)

Bonding jumper

b)

Grounding electrode conductor

c)

PVC cement

d)

PVC solvent

12.

A mechanical connector that is crimped unto a conductor for both splice and termination is known as

a)

Split bolt connector

b)

Solderless connector

c)

Mechanical lug

d)

Bolt connector

13.

What are the types of fittings commonly used for exposed conduit support?

a)

Condulet

b)

Connector

c)

Locknut and bushing

d)

Conduit Strap/Clamp

14.

One most advantage of using rubber insulation tape in splice is

a)

Does not deteriorate with age

b)

Is able to withstand high temperature

c)

Does not absorb much moisture

d)

All of the above

15.

When measuring load resistance, the ohmmeter is connected

a)

In series with the load

b)

Parallel with the source

c)

Across the terminals of the load

d)

From one load terminal to ground