Unit 205: Cold water systems — Sample questions

Total questions: 13

Worksheet time: 7mins

Name
Class
Date
1.

When installing a new indirect cold water system, which of the following should happen, according to the Water Regulations?

a)

One tap (normally kitchen sink) drawn directly from the supply pipe

b)

One tap (normally kitchen sink) should have a dedicated distribution pipe from the storage cistern

c)

Mixer taps will require double check valves

d)

Mixer taps should never be installed due to the pressure differences

2.

According to BS6700 and the Water Regulations, a drain off valve should be installed:

a)

At every draw off point

b)

At every high point in the system

c)

At every low point in the system

d)

Above the cold water storage cistern

3.

Pin holing in copper pipework is commonly caused by:

a)

Hard water

b)

Acidic water

c)

Alkaline water

d)

Pure water

4.

The use of WRAS approved fittings when installing cold water pipework is:

a)

A legal requirement

b)

To be corrosion resistant

c)

To avoid contamination

d)

All of the above

5.

What is the most cost effective way to repair a stop valve that has the head gear jammed open?

a)

Replace the head gear only

b)

Replace the whole valve

c)

Leave in position, and install a new stop valve upstream

d)

Repack the glands around the spindle.

6.

What is this item?

a)

Fullway gate valve

b)

Drain off valve

c)

Stop valve

d)

Spherical ball valve.

7.

When installing a new water service pipe to a property, it should normally be buried between what depths?

a)

135mm to 1,750mm

b)

350mm to 750mm

c)

1,350mm to 1,750mm

d)

750mm to 1,350mm.

8.

Which of the following materials is not allowed to be installed on new cold water systems?

a)

Copper

b)

Stainless steel

c)

MDPE

d)

Lead.

9.

What type of valve is designed to shut off the supply of water in a cistern at a predetermined level?

a)

Stop valve

b)

Fullway gate valve

c)

Float operated valve

d)

Isolation valve.

10.

The fluid category that offers a slight health risk to a customer is:

a)

1

b)

2

c)

3

d)

4

11.

The correct back flow protection device that would be installed prior to a shower mixer valve would be:

a)

Single check valve

b)

Double check valve

c)

RPZ valve

d)

Type AG air gap

12.

To protect category 1 water from category 3 water, what would need to be installed, according to the Water Regulations?

a)

Single check valve

b)

Double check valve

c)

RPZ valve

d)

Type AG air gap

13.

What would this item be used to test?

a)

Pressure

b)

Category of water

c)

Flow rate

d)

pH value