WorksheetsFinal Review
Total questions: 75
Worksheet time: 38mins
There are an average of 3 types of Powered Surgical Instruments
(a)
saw attachmens: 1, ______________moves front to back, ___2___ moves side to side, & ___3.___ moves in a full continuous circle.
(a)
Spell out the Acronym/Abbreviation provided: AAA
(a)
Spell out: Ex Lap
(a)
Spell out the Acronym/Abbreviation provided: IM
(a)
True or False. There are currently no commercial products or “household” methods available to verify the cleaning process outcomes for either an ultrasonic unit; or an automated washer.
(a)
Spell out the Acronym/Abbreviation provided: BKA
(a)
Due to the history & strength of the ultrasonic’s wave action and the washer/decontaminator’s splashing ability, a ratcheting instrument will still receive it’s entitled cleansing even if it’s left in the ratchet-locked position .
(a)
Despite an enzymatic detergent manufacturer’s guidelines, if the amount added to the water visually appears too weak, providing additional enzymatic detergent may ensure the instrument(s) receive a better clean .
(a)
Spell out SAD
(a)
True or False. The serrations that come longitudinal on some ratcheting instruments may be referred to as “truckmelt”.
(a)
T/F The name on a stainless steel instrument to look out for due to it possibly being disposable is “Afghanistan”.
(a)
To ensure the end of a scope lens is not foggy/smudged, a recommended tested item to use would be an Alcohol wipe for glass lens or sapphire lens.
(a)
True or False. Usually, Titanium instrumentation can be identified via a bright gold color.
(a)
Spell out the Acronym/Abbreviation provided: D&C
(a)
Spell out the Acronym/Abbreviation provided: EUA
(a)
Spell out the Acronym/Abbreviation provided: EEG
(a)
The three parameters that must be met involving steam (autoclave) sterilizers are: ____1.___, ____2.____, & ____3.___
(a)
True of False. The 2 types of steam sterilization methods under Dynamic-Air Removal are: Gravity Displacement & Ozone.
(a)
True of False. To avoid wet packs or condensation, a steam (autoclave) PPK item should be placed “face up” (w/the contents in view for the technician’s visualization) - just not “face down”
(a)
The apparatus for maintaining a constant and suitable temperature for favorable growth for Biological Indicators is known as a(n)
(a)
A typical Dynamic Steam Sterilizer has 4 phases under a pre vacuum cycle…name them in the correct order: dyring, exhaust, sterillization, conditioning
(a)
Spell out the Acronym/Abbreviation provided: I&D
(a)
True or False: A wide variety of plain-weave cotton or cotton/polyester fabrics used as a non-disposable (soft) wrap having approximately 140 threads per square inch is known as “canvas”
(a)
The inside walls/ceiling/floor area of the autoclave chamber should be cleaned weekly; to include the strainer drain of an autoclave steam sterilizer should be cleaned weekly
(a)
T/F: An exhaust hood for ETO is an example of a method for Administrative Control.
(a)
T/F: 3 parts: The disadvantages to EtO sterilization are: there are lumen restrictions to the device being processed; there is a long sterilization cycle; & it’s carcinogens requires critical monitoring for employees
(a)
The average cycle for EtO is between 4 to 5min. exposure; 30 to 45 min aeration
(a)
The amount (minor traces) of ETO that may remain inside materials after they are sterilized is known a
(a)
What is the designed steam sterilization container's name only authorized to have a small amount of water at the bottom good for a shelf-life of 48hrs
(a)
Spell this out: T&A
(a)
T/F: isolated from poss. infected contact; or, in the case of storage, possibly awaiting BI result that you can’t release a tray just yet, is known as being kept “sequestered”
(a)
The duration/length one must flush their eyes if exposed to any kind of exposure (i.e. blood; solution/chemicals; etc.) is 15 seconds.
(a)
The device used in Sterile Storage for measuring humidity within the work area is known as
(a)
Inventory replenishment system uses identical carts filled with supplies; one cart is dispensed to the user unit and the second cart is kept in standby
(a)
When items are needed immediately, or at once, Central Service Technicians may receive this instant order. (all caps - abbrev. onl)
(a)
Name the coined term TJC designed to use information from the HCF to follow the experience of care, treatment or services for a number of patients through the organization's entire health care delivery process
(a)
Spell out TURP
(a)
Spell out IOC
(a)
Two regulatory agencies that are responsible for regulating EO.
WHO and CDC
CDC and EPA
EPA and APIC
JCO and DOT
processing of flexible endoscopes
SGNA
EPIC
ANSI
EPA
This voluntary organization provides standards and evaluations ....inspections ...... “Tracer Methodology”]
Joint Commission
WHO
ANSI
OSHA
global competitiveness and quality of life by promoting standards and ensuring their integrity.
ANSI
CDC
AAMI
APIC
protects workers from occupationally-caused illnesses and injuries
OSHA
CDC
WHO
APIC
Establishes Sterilazation practices based on research, therory and opininion. Sets STANDARDs
AAMI
JCO
APIC
CDC
cleaner water air and land
EPA
CDC
JCO
OSHA
Agency improving health conditions
OSHA
CDC
WHO
EPA
Preventing and controlling disease
CDc
WHO
OSHa
AORN
Reccomended Practices for the Perioperative setting
CDC
SGNA
DOT
AORN
global competitiveness and quality of life by promoting standards and ensuring their integrity.
SGNI
ANSI
AAMI
JCO