High-Performance Liquid Chromatography (HPLC)

Total questions: 20

Worksheet time: 10mins

Name
Class
Date
1.

The main advantage of HPLC over conventional liquid chromatography is

a)

Use of volatile solvents

b)

Higher separation efficiency and speed

c)

Lower operating pressure

d)

Use of larger particle size stationary phases

2.

In HPLC, the stationary phase commonly used in reversed-phase chromatography is

a)

Silica gel

b)

Alumina

c)

C18 bonded silica

d)

Ion-exchange resin

3.

Which type of mobile phase is used in reversed-phase HPLC?

a)

Non-polar solvent

b)

Highly viscous solvent

c)

Polar solvent or solvent mixture

d)

Gas

4.

The typical particle size of packing material used in modern HPLC column is

a)

50-100 μm

b)

20-40 μm

c)

10-15 μm

d)

3-5 μm

5.

Which detector is most commonly used in pharmaceutical HPLC analysis?

a)

Flame ionization detector

b)

UV-Visible detector

c)

Thermal conductivity detector

d)

Mass flow detector

6.

The retention time of a compound in HPLC is best defined as

a)

Time taken for an analyte to elute from the column and reach the detector

b)

Time taken for the solvent to pass through the column

c)

Time taken for analyte injection

d)

Time taken for column equilibration

7.

Which parameter directly affects the resolution in HPLC?

a)

Injection volume only

b)

Flow rate, column efficiency, and selectivity

c)

Detector wavelength only

d)

Mobile phase volume

8.

In normal-phase HPLC, the stationary phase is

a)

Polar and hydrophilic

b)

Non-polar and hydrophobic

c)

Ion-exchange based

d)

Chiral

9.

Which of the following causes peak tailing in HPLC?

a)

Low detector sensitivity

b)

Excessive mobile phase flow rate

c)

Secondary interactions between analyte and stationary phase

d)

Short column length

10.

The function of a guard column in HPLC is to

a)

Improve detector response

b)

Reduce solvent consumption

c)

Protect the analytical column from contamination

d)

Increase retention time

11.

Increasing the mobile phase flow rate generally results in

a)

Increased retention time

b)

Decreased analysis time

c)

Increased column efficiency

d)

Improved peak symmetry

12.

Which of the following is a common application of HPLC in pharmaceutical analysis?

a)

Determination of boiling point

b)

Identification of crystal structure

c)

Measurement of melting point

d)

Assay and impurity profiling of drug substance

13.

The primary function of the degasser in an HPLC system is to

a)

Remove particulate matter from the mobile phase

b)

Prevent bubble formation in the pump and detector

c)

Increase mobile phase flow rate

d)

Stabilize column temperature

14.

An autosampler in HPLC is mainly used to

a)

Increase detector sensitivity

b)

Reduce system back pressure

c)

Improve reproducibility of sample injection

d)

Control column temperature

15.

The column oven in HPLC system is used to

a)

Maintain constant column temperature

b)

Increase analyte solubility

c)

Reduce solvent evaporation

d)

Prevent column blockage

16.

Which solvent is most commonly used as an organic modifier in reversed-phase HPLC?

a)

Hexane

b)

Methanol or acetonitrile

c)

Chloroform

d)

Toluene

17.

A photodiode array (PDA) detector allows

a)

Detection of non-chromophoric compounds only

b)

Higher sensitivity than MS detectors

c)

Simultaneous monitoring at multiple wavelengths

d)

Detection of volatile compounds only

18.

Baseline noise in HPLC chromatogram is often caused by

a)

Inconsistent sample preparation

b)

Mobile phase impurities or detector instability

c)

Low column efficiency

d)

Short retention times

19.

Which practice helps prolong the life of HPLC column?

a)

Using unfiltered samples

b)

Operating at maximum pressure

c)

Flushing with appropriate solvents after use

d)

Storing the column dry

20.

In normal-phase HPLC, polar analytes typically

a)

Elute faster than non-polar analytes

b)

Have a shorter retention times

c)

Show stronger interaction with the stationary phase

d)

Do not interact with the stationary phase