Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Quiz Fire Code

Total questions: 25

Worksheet time: 13mins

Name
Class
Date
1.

What is the minimum lot frontage of a regular lot for single-detached units as provided for in PD 957?

a)

6.00 m

b)

8.00 m

c)

10.00 m

d)

12.00 m

2.

What is the minimum floor area for an open market housing unit under PD 957?

a)

36.00 sqm

b)

42.00 sqm

c)

48.00 sqm

d)

60.00 sqm

3.

What is the minimum lot frontage of a corner lot for single-detached units as provided for in PD 957?

a)

8.00 m

b)

10.00 m

c)

12.00 m

d)

14.00 m

4.

Walkway headroom should not be less than this height and should preferably be higher.

a)

1.80 m

b)

2.00 m

c)

2.20 m

d)

2.40 m

5.

As per BP 220, what is the maximum length of a residential block?

a)

200 m

b)

300 m

c)

400 m

d)

500 m

6.

What is the minimum lot area for single-detached socialized housing units as provided for in BP 220?

a)

48.00 sqm

b)

54.00 sqm

c)

64.00 sqm

d)

72.00 sqm

7.

What is the minimum lot area for single-detached medium-cost housing units as provided for in PD 957?

a)

80 sqm

b)

100 sqm

c)

120 sqm

d)

150 sqm

8.

As per BP 344, what is the required minimum walkway width to permit a person in a wheelchair to traverse it with safety?

a)

0.90 m

b)

1.00 m

c)

1.20 m

d)

1.50 m

9.

As per BP 344, what is the maximum distance between rest stops or turn-around spaces in walkways?

a)

6 m

b)

9 m

c)

12 m

d)

15 m

10.

Any condition or act which increases or may cause an increase in the probability of the occurrence of fire is called what?

a)

Fire load

b)

Fire hazard

c)

Flashover

d)

Backdraft

11.

What is the minimum lot area for single-detached economic housing units as provided for in BP 220?

a)

54 sqm

b)

64 sqm

c)

72 sqm

d)

84 sqm

12.

A fire-resistive door prescribed for openings in fire separation walls or partitions is called what?

a)

Smoke door

b)

Fire door

c)

Exit door

d)

Access door

13.

As per BP 344, what is the maximum length of a ramp if the ramp gradient is 1:12?

a)

3 m

b)

6 m

c)

9 m

d)

12 m

14.

As per RA 9514, buildings over this height are required throughout to have an automatic fire sprinkler system.

a)

12.00 m

b)

15.00 m

c)

18.00 m

d)

21.00 m

15.

Separated from other spaces of the building by construction or equipment to provide a protected way of travel to the exit discharge describes what?

a)

Fire exit

b)

Horizontal exit

c)

Exit passageway

d)

Exit access

16.

A bar extending across at least one-half of each door leaf that opens the door when subjected to pressure is called what?

a)

Push plate

b)

Panic hardware

c)

Lever handle

d)

Door closer

17.

An integrated system of underground or overhead piping connected to a source of extinguishing agent that, when actuated by its automatic detecting device, suppresses fire is called what?

a)

Standpipe system

b)

Automatic fire suppression system

c)

Portable extinguisher network

d)

Smoke control system

18.

What is the minimum lot frontage of a corner lot for single-detached units as provided for in BP 220?

a)

6.00 m

b)

7.50 m

c)

8.00 m

d)

9.00 m

19.

What is the minimum width of parking slots for persons with disabilities (PWD)?

a)

3.00 m

b)

3.30 m

c)

3.50 m

d)

3.70 m

20.

What is the minimum lot frontage of a regular lot for single-detached units as provided for in BP 220?

a)

6.00 m

b)

7.00 m

c)

8.00 m

d)

9.00 m

21.

What is the minimum depth of a central refuge?

a)

1.00 m

b)

1.20 m

c)

1.50 m

d)

1.80 m

22.

What is the minimum lot area for single-detached open market housing units as provided for in PD 957?

a)

100 sqm

b)

110 sqm

c)

120 sqm

d)

140 sqm

23.

A passageway from one building to another or around a wall at approximately the same floor level is called what?

a)

Horizontal exit

b)

Exit access corridor

c)

Exit passageway

d)

Enclosed stair

24.

As per BP 220, what is the minimum clear width of stairways?

a)

0.60 m

b)

0.75 m

c)

0.90 m

d)

1.00 m

25.

As per RA 9514, what is the maximum travel distance for places of assembly if not protected by an automatic fire suppression system?

a)

36 m

b)

40 m

c)

46 m

d)

60 m