Monitoring and Record Keeping Lab part one

Slide image

2

The Bowie-Dick test

To test the pre-vac sterilizer's air removal system

3

Slide image

4

Multiple Choice

The Bowie-Dick test indicator turns from black to yellow

1

true

2

false

5

Whats wrong with this picture?

I will explain.

Slide image

6

The growth medium starts out bluish and changes to yellow when the bacteria is alive and well.

7

This is an unprocessed biological, notice the pink strip. That is a chemical indicator that turns brown when exposed to steam.

Slide image

8

These strips are both brown. One of these is a bad test result. Can you tell which is bad?

Slide image

9

Multiple Select

Select the true statements

1

the yellow one has been through a sterilization cycle and the bacteria are still alive, this is not good.

2

the one on the right is a control and is supposed to be yellow.

3

the blue one has been through a sterilization cycle and the bacteria are not growing, it appears they are dead and we have sterilization.

10

Let's plant the bug

(put the biological into the incubator)

11

We'll need to record several things

It's as easy as answering questions to which we know the answer.

12

Here is a sample of a biological testing log sheet

This is not representative of all facilities.

13

Slide image


The questions to be answered are blacked out on this example

This is a sample and does not represent all facilities log sheets.

14

Question: What sterilization run is the amplule associated with?

does not apply to controls which are not associated with any run.
More on controls later.

15

Slide image

place load tracking information sticker here (lot sticker)

16

Question: what date was the load was run?

17

Slide image

the date the load was run

18

Question: what is the lot number of the Test or Control?

19

The lot number here is 2019-12DD

Slide image

20

This unprocessed ampule shows the lot number 2019-12DD

(the pink strip turns brown when exposed to steam)

Slide image

21

Each lot number for test packs being used in any given day must be shown to be viable by growing a control of the same lot number

22

If you switch lot numbers during any given day you must also grow a control of the new lot number

23

Slide image

record the lot number 

24

Question: what is the result of the integrator?

accept or reject?

25

Slide image

circle one

26

Question: Placement of the ampule in the incubator?

27

Slide image

28

Date and time the ampule is placed in the incubator? Initials of the tech?

29

Slide image

30

Date and time the ampule is removed from the incubator? Initials of the tech?

31

Slide image

32

Record the result of test.
The test is the ampule that went through a sterilization process.

negative is good, positive is bad

33

Slide image

34

Record the control result

positive is good, negative is bad

35

Slide image

For rapid read out record the result and leave the control in the incubator for 24 hours. Do not remove control or fill in date/time of removal before the 24 hours has elapsed. 

36

Slide image

After 24 hours you may log control out. 
Be sure to verify the identity of the ampule you are removing from the incubator.

37

Slide image

control logged out after 24 hours, test logged out same day

38

Note: The examples of biological indicators used here are of a 3 hour read-out manufactured by 3M

39

Poll

I learned from this presentation.

Agree

Disagree

Monitoring and Record Keeping Lab part one

Slide image

Show answer

Auto Play

Slide 1 / 39

SLIDE